Powered by Google-Search & Google-Books Chinese Standards Shop Database: 169760 (Nov 21, 2020)
HOME   Quotation   Tax   Examples Standard-List   Contact-Us   View-Cart
  

CJ 128-2007

Chinese Standard: 'CJ 128-2007'
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusRelated Standard
CJ 128-2007English180 Add to Cart 0--10 minutes. Auto immediate delivery. Heat meters Obsolete CJ 128-2007
CJ 128-2007Chinese29 Add to Cart <=1-day [PDF from Chinese Authority, or Standard Committee, or Publishing House]

  In 0~10 minutes time, full copy of this English-PDF will be auto-immediately delivered to your email. See samples for translation quality.  

BASIC DATA
Standard ID CJ 128-2007 (CJ128-2007)
Description (Translated English) Heat meters
Sector / Industry Urban Construction Industry Standard
Classification of Chinese Standard N11;P40
Classification of International Standard 91.140.60
Word Count Estimation 41,473
Date of Issue 2007-10-15
Date of Implementation 2008-04-01
Older Standard (superseded by this standard) CJ 128-2000
Quoted Standard Ministry of Construction Industry Standards Bulletin No. 721
Adopted Standard EN 1434-2007, NEQ
Drafting Organization Institute of Urban Construction
Administrative Organization Ministry of Construction of urban construction standards technical focal Academy of Urban Construction
Regulation (derived from) Ministry of Construction Industry Standards Bulletin No. 721
Summary This standard specifies the terms calorimeter, technical characteristics, technical requirements, test methods, inspection rules, marked, packaging and storage conditions. This standard applies to the flowing medium is water at a temperature of 4��C ~ 150��C, pressure is less than 2. 5MPa heat meters.

CJ 128-2007
GB
INDUSTRY STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 91.140.60
P 40
Replacing CJ 128-2000
Heat Meters
热量表
ISSUED ON. OCTOBER 15, 2007
IMPLEMENTED ON. APRIL 1, 2008
Issued by. Ministry of Construction of the People's Republic of China
Table of Contents
1 Scope ... 5 
2 Normative References ... 5 
3 Terms and Definitions ... 6 
4 Technical characteristics ... 9 
5 Requirements ... 12 
6 Test Method ... 17 
7 Inspection rules ... 22 
8 Marking, Packing and Storage ... 24 
Annex A (Informative) Water density and enthalpy value ... 26 
Annex B (Normative) Photoelectric interface ... 29 
Annex C (Normative) Structure and Installation of Platinum Resistance Temperature
Sensor ... 33 
Annex D (Normative) Test and calculation for metering accuracy of heat meter ... 47 
Annex E (Normative) Test and calculation for calculator accuracy ... 48 
Annex F (Normative) Test and calculation of temperature sensor accuracy ... 50 
Annex G (Normative) Test and calculation of flow sensor accuracy ... 53 
Foreword
The articles 4.2.2 4.2.4 4.2.5 4.3.2 4.3.3 and 5.1~5.12 in this Standard are compulsory
ones; the rest are recommendatory.
This Standard replaces CJ-128-2000 "Heat Meters", from the implementation date.
This Standard is the revision to CJ 128-2000 "Heat Meters". This revision references
to EU standard EN 1434-2007 "Heat meters". The major technical contents are
consistent with EN 1434; and it is consistent with JJG 225 "Verification Regulation of
heat Meters".
Compared with CJ 128-2000, the following aspects have been made to this Standard.
— Extend the flow-rate application scope of heat meter; add the requirements of
the heat meter with low flow-rate and large caliber;
— Add the requirements in installation length of heat meters;
— Add the requirements in pipe network water quality;
— Add the related requirements in cooling meter;
— Add Class C environmental requirement of heat meter;
— Add the requirements in data storage;
— Add the requirements in repetitiveness;
— Raise the requirements in electromagnetic compatibility;
— Raise the requirement in water temperature of exit-factory test; specify the
different water temperature conditions according to the type of heat meter in
type approval test;
— Delete the change size structural styles not used in China; make significant
amendment on installation drawing in the requirements in structure and
installation of platinum resistance temperature sensor;
— Add the technical requirements in photoelectric interface of heat meter;
— Add the requirements in the communication protocol used in heat meter data
transfer;
— Delete the technical contents in prepayment devices in Annex G in the former
standard.
Annex B, Annex C, Annex D, Annex E, Annex F and Annex G in this Standard are
normative; Annex A is informative.
Heat Meters
1 Scope
This Standard specifies terms and definitions, technical characteristic, requirement,
test method, test rules, marking, packing, and storage of heat meters.
This Standard is applicable to heat meters of which the flowing medium is water, the
temperature is 2°C~150°C, and the pressure is not larger than 2.5 MPa.
2 Normative References
The following normative documents contain provisions which, through reference in
this text, constitute that provisions of this Standard. For dated reference, the
subsequent amendments or revisions of these publications do not apply. Parties who
reach an agreement based on this Standard are encouraged to investigate the
possibility of applying the most recent editions of the standards indicated below. For
undated references, the latest edition of the normative document referred to applies.
GB 191 Packaging - Pictorial marking for handling of goods
GB/T 2423.1 Environmental testing - Part 2. Test methods - Tests A. Cold
GB/T 2423.2 Environmental testing - Part 2. Test methods - Tests A. Dry heat
GB/T 2423.3 Environmental testing - Part 2. Test methods - Tests A. Damp heat
Steady
GB/T 2423.4 Environmental testing for electric and electronic products - Part 2.
Test method - Test Db. Damp heat, cyclic (12h+12h cycle)
GB 4208-1993 Degrees of protection provided by enclosure (IP code)
GB 4706.1 Household and similar electrical appliances - Safety - Part 1. General
requirements
GB/T 9113.1 Integral steel pipe flanges with flat face or raised face
GB/T 17626.2 Electromagnetic compatibility (EMC) - Testing and measurement
techniques - Electrostatic discharge immunity test
GB/T 17626.3 Electromagnetic compatibility - Testing and measurement
techniques - Radiated radio-frequency electromagnetic field immunity test
GB/T 17626.4 Electromagnetic compatibility - Testing and measurement
techniques - Electrical fast transient/burst immunity test
GB/T 17626.5 Electromagnetic compatibility - Testing and measurement
techniques - Surge immunity test
GB/T 17626.8 Electromagnetic compatibility (EMC) - Part 4-8. Testing and
measurement techniques - Power frequency magnetic field immunity test
GB/T 17626.11 Electromagnetic compatibility - Testing and measurement
techniques - Voltage dips, short interruptions and voltage variations immunity tests
CJJ 34 Design code of district heating network
CJ/T 188-2004 Technical requirements of utility meters data transmission
JB/T 9329 Basic environmental conditions and testing methods for instruments
transportation and storage in the transportation
3 Terms and Definitions
The following terms and definitions apply to this Standard.
3.1
Heat meter
Meter that meters and displays the heat energy that the water-flow releases or
absorbs when passing heat exchange system.
3.2
Complete heat meter
Non-decomposable heat meter consisted of flow sensor, calculator and temperature
sensor pair.
3.3
Combined heat meter
Heat meter consisted of flow sensor, calculator and temperature sensor pair.
3.4
Cooling meter
Heat meter that meters the cooling amount in which the fluid medium temperature is
2°C~ 30°C and the temperature difference is not higher than 20K.
3.12
Maximum temperature difference
Upper limit value of a temperature difference, under which the accuracy of a heat
meter shall not exceed the error limit.
3.13
Flow-rate
Volume or mass of the heat carrier water that flows across a heat meter in unit time.
3.14
Minimum flow-rate
Lower limit of the flow-rate of water-flow that flows across a heat meter, under which
the accuracy of a heat meter shall not exceed the error limit.
3.15
The permanent flow-rate
Water flow-rate of a system under long-term normal continuous operation, under
which the accuracy of a heat meter shall not exceed the error limit.
3.16
Maximum flow-rate
Water extreme flow-rate of the water-flow that flows across a heat meter under normal
operation condition in a short time (1 h/d; <200 h/a), under which the accuracy of a
heat meter shall not exceed the error limit.
3.17
Total volume
Total volume of water flowing across a heat meter.
3.18
The highest temperature
Maximum allowable temperature of water, when the accuracy of a heat meter does
not exceed the error limit.
3.19
The lowest temperature
Minimum allowable temperature of water, when the accuracy of a heat meter does not
exceed the error limit.
3.20
Maximum admissible working pressure
Maximum working pressure that a heat meter can bear with when it continuously
works under the highest temperature.
3.21
Pressure loss
Loss of pressure caused by a heat meter at specified flow-rate.
3.22
Admissible pressure loss
Limit of pressure loss of the water-flow that flows across a heat meter at permanent
flow-rate.
3.23
Maximum thermal power
Possible maximum value of thermal power when the accuracy of a heat meter does
not ......
Related standard:   CJJ 128-2017
Related PDF sample:   GB/T 19146-2010  GB/T 22065-2008
   
 
Privacy   ···   Product Quality   ···   About Us   ···   Refund Policy   ···   Fair Trading   ···   Quick Response
Field Test Asia Limited | Taxed in Singapore: 201302277C | Copyright 2012-2020