HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (9 Mar 2025)

AQ/T 3001-2021 English PDF (AQ3001-2005)

AQ/T 3001-2021_English: PDF (AQ/T3001-2021)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
AQ/T 3001-2021English309 Add to Cart 3 days [Need to translate] (Technical requirements for barrier and explosion-proof of oil (gas) storage tanks at gas (gas) stations) Valid AQ/T 3001-2021
AQ 3001-2005English190 Add to Cart 0--9 seconds. Auto-delivery Technology-separate and explosion-proof of gasoline, gas filling station and light-fuel, LPG tank of transportation by truck Obsolete AQ 3001-2005


BASIC DATA
Standard ID AQ/T 3001-2021 (AQ/T3001-2021)
Description (Translated English) (Technical requirements for barrier and explosion-proof of oil (gas) storage tanks at gas (gas) stations)
Sector / Industry Industrial Safety Standard (Recommended)
Classification of Chinese Standard C67
Word Count Estimation 13,152
Date of Issue 2021-02-19
Date of Implementation 2021-08-01
Older Standard (superseded by this standard) AQ 3001-2005
Regulation (derived from) Ministry of Emergency Management Announcement No. 3 of 2021

BASIC DATA
Standard ID AQ 3001-2005 (AQ3001-2005)
Description (Translated English) Technology-separate and explosion-proof of gasoline, gas filling station and light-fuel, LPG tank of transportation by truck
Sector / Industry Industrial Safety Standard
Classification of Chinese Standard C67
Classification of International Standard 13.230
Word Count Estimation 12,146
Date of Issue 2005-04-13
Date of Implementation 2005-10-01
Quoted Standard GB 150; GB 15322; GB 15322; GB 15322; GB 15322; GB 15322; GB 18564; GB 18564; GB 18564; HG 23011-1999; HG 23012
Drafting Organization Explosion-proof Technology Co., Ltd. Beijing China Tenta
Administrative Organization National Security State Administration of Work Safety
Regulation (derived from) 2005 Bulletin No. 7 line marked
Summary This standard specifies the use of explosion-proof barrier technology vehicle refueling (gas) station and car transport with light fuel oil, liquefied petroleum gas tank explosion-proof barrier (tank) of classification and labeling, requirements, test methods, inspection rules, and technical documents. This standard applies to automotive fuel (gas) station, light fuel oil, liquefied petroleum gas tank car tanks with explosion-proof barrier (hereinafter referred to as tanks) the design, manufacture, installation and acceptance.


AQ 3001-2005 AQ SAFETY PRODUCTION STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 13.230 C 67 Filing number: 15858-2005 Technology-separate and explosion-proof of gasoline, gas filling station and light-fuel, LPG tank of transportation by truck ISSUED ON: APRIL 13, 2005 IMPLEMENTED ON: OCTOBER 01, 2005 Issued by: State Administration of Work Safety Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative references ... 4  3 Terms and definitions ... 5  4 Classification and marking ... 6  5 Requirements ... 8  6 Testing method ... 11  7 Inspection rules ... 14  8 Technical documents ... 15  Appendix A (Normative) Marking of tank using separate and explosion-proof technology ... 16  Technology-separate and explosion-proof of gasoline, gas filling station and light-fuel, LPG tank of transportation by truck 1 Scope This standard specifies the classification and marking, requirements, testing methods, inspection rules and technical documents of automobile gasoline (gas filling) stations that adopt the separate and explosion-proof technology as well as the light fuel oil and liquefied petroleum gas separate and explosion-proof storage tanks (tanks) for automobile transportation. This standard applies to the design, manufacture, installation and acceptance of separate and explosion-proof storage tanks for gasoline (gas filling) stations, light fuel oil, LPG tank cars. 2 Normative references The provisions in following documents become the provisions of this Standard through reference in this Standard. For the dated references, the subsequent amendments (excluding corrections) or revisions do not apply to this Standard; however, parties who reach an agreement based on this Standard are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest edition of the referenced document applies. GB 150 Steel pressure vessel GB 15322 Technical requirements and test methods for combustible gas detectors GB 18564 General specification for normal pressure tank body of transportation liquid dangerous goods HG 23011-1999 The safety code for hot work in workplace HG 23012 The safety code for vessel entry in workplace Ministry of Labor Ministry of Labor [1994] No.262 Safety Supervision Regulations for Liquefied Gas Tank Trucks liquid, the ratio of the volume of the liquid replaced to the volume of the tank. 3.7 Washing passage A channel as reserved at the bottom of the tank for removing dirt and residue. 3.8 Well A bracket installed at the manhole of the tank with an upper end fixed to the manhole and a lower end connected with the cleaning channel. 3.9 Internal unit A column or multi-faceted column made of metal mesh packed in the well with the separate and explosion-proof material filled inside. 3.10 Construction piece The components used to support the separate and explosion-proof materials, well, and position the cleaning channels in the tank, which are generally composed of one or several units. 3.11 Increases of pressure by burning explosion Under the same test conditions, the pressure value after the explosion test without and with the installation of the separate and explosion-proof material is measured. The difference between the two and the initial pressure value before the explosion test is the increase of pressure by burning explosion, which can be used to evaluate the explosion-proof performance of the separate and explosion-proof material. 4 Classification and marking 4.1 Classification 4.1.1 Classification by separate and explosion-proof materials Separate and explosion-proof materials are divided into five types: Type I, Type 5.3.1 Cleaning before implementing separate and explosion-proof technology Implementation of cleaning of separate and explosion-proof technology storage tank adopts different solutions for new storage tanks and in-use storage tanks. 5.3.1.1 New tank cleaning 5.3.1.1.1 Inspect and determine the reagents for the tank leakage test. 5.3.1.1.2 Choose an appropriate cleaning agent for cleaning operations. 5.3.1.1.3 The safety analysis and qualification criteria are as follows: a) When using an explosion detector or other similar means, the measured gas or vapor concentration shall be less than or equal to 20% of the lower explosion limit; b) When using other analytical methods, when the lower explosive limit of the measured gas or vapor is greater than or equal to 4%, the measured concentration is less than or equal to 0.5%; when the measured lower explosive limit of the gas or vapor is less than 4%, the measured concentration is less than or equal to 0.2%; c) Other requirements shall comply with the provisions of Chapter 6 in HG 23011-1999. 5.3.1.1.4 The operations in the equipment shall comply with the requirements of HG 23012. 5.3.1.2 In-use tank cleaning 5.3.1.2.1 In order to ensure the construction safety in the transformation process of the separate and explosion-proof storage tank; the storage tank shall be cleaned before transformation. Before cleaning, it shall check and determine the leakage of the storage tank. If it leaks, it shall be repaired and welded to prevent leakage. Cleaning shall meet the requirements of 5.3.1.1.1 and 5.3.1.1.2 of this standard. 5.3.1.2.2 The safety analysis and qualification criteria shall be in accordance with the provisions of 5.3.1.1.3 of this standard. 5.3.1.2.3 The operations in the equipment shall comply with the requirements of HG 23012. 5.3.2 Cleaning of storage tanks after separate and explosion-proof technology transformation 5.5 Explosion-proof requirements The Increases of pressure by burning explosion of the separate and explosion- proof device shall be less than or equal to 0.14 MPa. 6 Testing method 6.1 Testing of separate and explosion-proof materials 6.1.1 Material appearance quality The appearance quality of the separate and explosion-proof materials shall be inspected by straightedge and visual inspection methods, which shall meet the requirements of 5.2.1. 6.1.2 Material structure size Use a vernier caliper to check the structural size of the separate and explosion- proof material, which shall meet the requirements of 5.2.2. 6.2 Safety testing of cleaning operation Determination of the concentration of flammable and explosive gas or vapor. 6.2.1 Explosion detector or other similar means for testing The explosion detector shall meet the requirements of GB 15322. The testing range of its concentration shall comply with the provisions of item 1) of 5.3.1.1.3. 6.2.2 Use other analytical methods for testing Test according to the relevant standards of various testing objects The testing range of its concentration shall comply with the provisions of item 2) in 5.3.1.1.3. 6.3 Installation quality testing 6.3.1 Fulling density Measuring tools: General measuring tools. Measurement conditions: Measure the dimensions of the separate and explosion-proof material unit, accurate to millimeters; calculate the volume. Put the separate and explosion-proof material unit on a balance, accurate to grams; 6.4.3 Test conditions 6.4.3.1 The pressure sensor shall meet the following requirements: a) Range: 0 ~ 10 MPa; b) Sensitivity: 140 pC/MPa. 6.4.3.2 The pressure gauge shall meet the following requirements: a) Range: 0 ~ 10 MPa; b) Accuracy level: 1.6. 6.4.3.3 The test shall be carried out at room temperature of 20 °C ± 5 °C. 6.4.4 Specimen and installation The test specimen shall be the separate and explosion-proof material which passes the acceptance in accordance with 5.2.1 and 5.2.2. The size of the specimen shall be properly matched with the inner wall of the test container; the cross-sectional area of the specimen shall not be less than 98% of the cross-sectional area of the inner cavity of the test container. During the test, the crevice rate inside the test device is 5%. The volume without filling specimen includes the volume occupied by the observation window. Except for the volume occupied by the observation window, the remaining volume without filling specimen shall be located at one end of the ignition source. 6.4.5 Test procedure a) The air tightness of the test device shall be checked before the test; perform explosion test of the explosive mixture before the test; b) Pack the medium in the batching container; c) Turn on the circulating pump and operate for more than 7 minutes, to ensure that the mixture in the test container and the combustion explosion container is uniform; d) Record the initial pressure (gauge pressure) of the pressure sensor at this time; close each valve; e) Test ignition; f) Record the peak pressure (gauge pressure) of each pressure sensor. 7.2 Installation inspection includes all inspection items. 7.2.1 The test method for the testing of separate and explosion-proof materials shall be in accordance with the provisions of clause 6.1. 7.2.2 The test method for safety testing of cleaning operation shall be in accordance with the provisions of clause 6.2. 7.2.3 The test method of installation quality testing shall be in accordance with the provisions of clause 6.3. 7.2.4 The test method for the testing of explosion-proof performance shall be in accordance with clause 6.4. 7.3 During the installation inspection, if any item does not meet the relevant requirements of 6.1 ~ 6.4, the installation is determined to be unqualified. When the installation fails, it shall be repaired and resubmitted for inspection. 8 Technical documents 8.1 Inspection certificate Storage tanks using separate and explosion-proof technology shall have an inspection certificate. The inspection certificate must include the name and model of the installation organization, inspection date and inspector code, etc. 8.2 Instruction manual Storage tanks using separate and explosion-proof technology shall have instruction manual, which includes the shelf life, cleaning methods and daily maintenance requirements of separate and explosion-proof materials. ......

Similar standards: AQ/T 8012-2022  AQ 7013-2018  AQ 4241-2015  
Similar PDFs (Auto-delivered in 9 seconds): AQ 3001-2005  GB 15577-2018  GB/T 15605-2008