JJF 1274-2011 English PDF

JJF 1274-2011_English: PDF (JJF1274-2011)
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
JJF 1274-2011349 Add to Cart 3 days Calibratlsn Speciflartien for Kinematic Viscosity Tester Valid
JJF 1274-1990199 Add to Cart 2 days (IF (2 ~ 100kHz) sound pressure water base operating technical specifications) Obsolete

BASIC DATA
Standard ID JJF 1274-2011 (JJF1274-2011)
Description (Translated English) Calibratlsn Speciflartien for Kinematic Viscosity Tester
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A61
Classification of International Standard 17.060
Word Count Estimation 15,146
Date of Issue 2011-01-21
Date of Implementation 2011-04-21
Quoted Standard ASTM D445; GB/T 265-1988; JJG 155-1991; ISO 3104-1994; JJF 1030-2010
Summary This standard is applicable for measuring viscosity range 0. 3 ~ 30000mm2/s, temperature range of 20 ~ 100��C kinematic viscosity measuring device calibration.


JJF 1274-2011 Calibratlsn Speciflartien for Kinematic Viscosity Tester People's Republic of China National Metrology Technical Specifications Kinematic viscosity measurement calibration specification Issued on. 2011-01-21 2011-04-21 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Kinematic viscosity measurement calibration specification Tester This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on January 21, 2011, and from From April 21, 2011 into effect. Focal point. the National Technical Committee stoichiometric physical Drafting Unit. Liaoning Provincial Institute of Metrology Measurement Science and Technology Institute in Fujian Province Participated in the drafting unit. Dalian metrological verification tests This specification stoichiometric commissioned National Technical Committee is responsible for the physical interpretation The main drafters of this specification. Aiming Ze (Liaoning Provincial Institute of Metrology) Luo Feng (Fujian Institute of Measurement Science Technology) Jinlong Jun (Liaoning Provincial Institute of Metrology) Li Wei (Liaoning Provincial Institute of Metrology) Drafters participate. Tang Jing (Dalian metrological verification tests) table of Contents 1 Scope (1) 2. Referenced Documents (1) 3 Overview (1) 4 Metrological characteristics (1) Calibration Condition 5 (2) 5.1 environmental conditions (2) 5.2 Calibration Equipment (2) 6 calibration items and calibration methods (2) 6.1 appearance inspection (2) 6.2 Temperature fluctuation (2) 6.3 Temperature uniformity (3) Viscosity measurement error 6.4 (3) 6.5 Repeatability Measurement (4) 6.6 Reproducibility measurement (4) 7 Calibration Results The expression (4) 8 Recalibration interval (4) Appendix A calibration record format (5) Appendix B Calibration Certificate page format (7) Uncertainty Analysis Examples Appendix C kinematic viscosity measurement error (9) Kinematic viscosity measurement calibration specification 1 Scope This specification is suitable for measuring viscosity in the range of 0.3mm2/s ~ 30000mm2/s, temperature range is 20 ℃ ~ Kinematic viscosity measuring device 100 ℃ calibration. 2 Citations ASTMD445 StandardTestMethodforKinematicViscosityofTransparentand Opaqueliquids (Standard Test Method for transparent and opaque liquid kinematic viscosity) GB/T 265-1988 Petroleum products - Determination of kinematic viscosity and dynamic viscosity calculation JJG155-1991 working capillary viscometer test procedures ISO 3104.1994 Petroleumproducts-Transparentandopaqueliquids-Determination ofkinematicviscosityandcalculationofdynamicviscosity (Transparent And calculation methods opaque petroleum products kinematic viscosity) JJF 1030-2010 bath technical performance test specification When using this specification it should be noted that using the currently valid version of the documents cited. 3 Overview Kinematic viscosity measured mainly by thermostatic bath, temperature control system, timing system, composed of a capillary viscometer for Measuring kinematic viscosity of the liquid at different temperatures. At a constant temperature, the desired capillary measuring a volume of fluid flowing in a standard viscosity of gravity Between t, according to equation (1) calculate the standard viscosity fluid kinematic viscosity and its standard value, or according to formula (1) to calculate viscosity Meter constant. ν = Ct (1) Where. ν --- liquid kinematic viscosity, mm2/s; C --- viscometer constant, mm2/s2; T --- a volume of liquid flowing through a capillary time, s. 4 Metrological characteristics Metrological characteristics are shown in Table 1. Table 1 metrological characteristics No. calibration items Technical Specifications Precision Industrial 1 Temperature fluctuation ± 0.01 ℃ ± 0.1 ℃ 2 temperature uniformity ≤0.02 ℃ ≤0.2 ℃ ......

Similar standards: JJF 1441   JJF 1424   JJF 1363   JJF 1891   JJF 1272   JJF 1267