Powered by Google-Search & Google-Books Chinese Standards Shop Database: 169760 (Aug 8, 2020)
HOME  COVID-19   Quotation   Tax   Examples Standard-List   Contact-Us   View-Cart
  

SNT3927-2014

Chinese Standard: 'SNT3927-2014'
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusRelated Standard
SN/T 3927-2014English135 Add to Cart 0--15 minutes. Auto immediate delivery. Determination of sodium thiocyanate in dairy products for export Valid SN/T 3927-2014
SN/T 3927-2014Chinese28 Add to Cart <=1-day [PDF from Chinese Authority, or Standard Committee, or Publishing House]

  Google-Books (Full-PDF will be auto-delivered in 0~10 mins):   GB/T 16604-2008  SN/T 3927-2014  SN/T 1600-2005  SN/T 0800.1-2016
In 0~10 minutes time, full copy of this English-PDF will be auto-immediately delivered to your email. See samples for translation quality.  
SN/T 3927-2014
Determination of sodium thiocyanate in dairy products for export
2014-04-09 ~ {jj"
~'4\"www cntw315 corn
ll!.i<'i4006982315
20 14-11-0 1 ~Mi!
Foreword
The standard are compiled according as the GB/T 1.1-2009.
The standard was proposed by and is under the charge of the Certification and Accreditation Admin-
istration of the People's Republic of China.
The standard was drafted by Shandong Entry-Exit Inspection and Quarantine Bureau of the People's
Republic of China, Shanxi Entry-Exit Inspection and Quarantine Bureau of the People's Republic of
China, Hunan Academy of Inspection and Quarantine.
The standard was mainly drafted by Hu Qiaoru, Yang Lijun, Wang Jing, Dulijun, Cui Fengj ie,
Song Xiaohua,Cong Weihong,Liu Yumin,Fu Yingwen,Cui He,Zhai Jinyi,Zhao Youyou,Liu Hongyan,
Yao Yating, Huang zhiqiang.
Determination of sodium thiocyanate in
dairy products for export
1 Scope
This standard specifies the ion chromatographic method and gas chromatographic method for the de-
termination of sodium thiocyanate in dairy products of export.
This standard is applicable to the determination of sodium thiocyanate in sterilized milk, pasteurized
milk, yoghurt, formula milk, milk beverage,milk powder, formula milk powder, cheese and condensed
milk of export.
2 Normative references
The following referenced documents are indispensable for the application of this document. For
dated references,only the edition cited applies. For undated references, the latest edition of the ref-
erenced document (including any amendments) applies.
GB/T 6682 Water for analytical laboratory use-Specification and test method
Ion chromatography
3 Principle
The sample was extracted and precipitated protein with acetonitrile, then the extract was cleaned,
separated by anion exchange column, potassium hydroxide solution as eluent. The determination was
aceieved by ion chromatography equipped with conductance detector,qualitatified with the retention
time and quantified by external standard method.
4 Reagents and materials
Unless otherwise specified, the reagents used should be analytical pure. And the water should comply
with the requirement of GB/T 6682 (first class water).
4.1 Sodium thiocyanate standard CNaSCN,CAS No..540-72-7) .purity;?..99.99%.
tate protein at room temperature and then centrifuge at 6 OOO r/min for 10 min. Accurately pipette
1.0 ml (V2 ) of the supernatant into a color comparison tube with cap,dillute to 10 ml (V3 ) with
water, shake it on the vortex mixer and take the extract to filter through a 0.22 µm membrane, then
cleaned by SPE column(for example Guard II RP column) ,discard the first 3 ml of solution and take
the middle section of the filtrate for Ion chromatography determination. If the sodium thiocyanate
exceeds the range of the standard curve, the sample amount should be reduced or the multiple should
be increased.
7 .1.2 Solid sample
Accurately weigh 1.0 g test sample (accurate to 0.01 g) into a color comparison tube with cap, add
4 g water and shake it on the vortex mixer for 2 min, then dillute to 10 ml( V1 )with acetonitrile. Mix
it well on the vortex, then stand for 20 min to precipitate prettied at room temperature and then cen-
trifuge at 6 OOO r/min for 10 min. Accurately pipette 1.0 ml ( V2 ) of the supernatant into a color
comparison tube with cap,dillute to 10 ml ( V3) with water,shake it on the vortex mixer and take
the extract to filter through a 0.22 µm membrane, then cleaned by SPE column(for example Guard II
RP column) ,discard the first 3 ml of solution and take the middle section of the filtrate for Ion chro-
matography determination. If the sodium thiocyanate exceeds the range of the standard curve, the
sample amount should be reduced or the multiple should be increased.
7 .2 Chromatography operating conditions
7.2.1 Chromatography column. hydroxide selective, high-capacity anion exchange column compatible with
gradient elution,for example Ion Pac® AS 16,4 mm x 250 mm (with Ion Pac® AG 16,4 mm x 50 mm
guard column).
7 .2.2 The temperature of column. 30 °C.
7.2.3 Eluent. potassium hydroxide solution, the concentration of 45 mmol/l-60 mmol/l,utilizing a
gradient elution program (0.00 min-13.00 min,45.0 mmol/l;13.00 min-18.00 min,60.0 mmol/l;
18.00 min-23.00 min,45.0 mmol/l).
7 .2.4 Suppressor. ASRS-300 4 mm anion suppressor; external water suppression mode (flow rate.
1.5 ml/min) ,suppression current is 112 mA-149 mA.
7.2.5 Flow rate. 1.0 ml/min.
7 .2.6 Injection volume. 100 µL.
7 .2. 7 Detector. conductance detector.