Powered by Google-Search & Google-Books Chinese Standards Shop Database: 169760 (Sep 19, 2020)
HOME   Quotation   Tax   Examples Standard-List   Contact-Us   View-Cart
  

GBT18886-2019

Chinese Standard: 'GBT18886-2019'
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusRelated Standard
GB/T 18886-2019English100 Add to Cart 0--15 minutes. Auto immediate delivery. Textiles -- Tests for colour fastness -- Colour fastness to saliva Valid GB/T 18886-2019
GB/T 18886-2019Chinese15 Add to Cart <=1-day [PDF from Chinese Authority, or Standard Committee, or Publishing House]  

  Google-Books (Full-PDF will be auto-delivered in 0~10 mins):   GB/T 18487.2-2017  GB 4806.1-2016
In 0~10 minutes time, full copy of this English-PDF will be auto-immediately delivered to your email. See samples for translation quality.  
GB/T 18886-2019
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 59.080.01
W 04
Replacing GB/T 18886-2002
Textiles - Tests for colour fastness -
Colour fastness to saliva
纺织品 色牢度试验 耐唾液色牢度
ISSUED ON: JUNE 04, 2019
IMPLEMENTED ON: JANUARY 01, 2020
Issued by: State Administration for Market Regulation;
Standardization Administration of the PRC.
Table of Contents
Foreword ... 3 
1 Scope ... 5 
2 Normative references ... 5 
3 Principle ... 6 
4 Equipment and materials ... 6 
5 Samples ... 8 
6 Operating procedures ... 9 
7 Test report ... 10 
Textiles - Tests for colour fastness -
Colour fastness to saliva
1 Scope
This Standard specifies the test method for the determination of the colour
fastness to saliva of textiles.
This Standard applies to all kinds of textiles.
2 Normative references
The following documents are indispensable for the application of this document.
For the dated references, only the editions with the dates indicated are
applicable to this document. For the undated references, the latest edition
(including all the amendments) are applicable to this document.
GB/T 250 Textiles - Tests for colour fastness - Grey scale for assessing
change in colour
GB/T 251 Textiles - Tests for colour fastness - Grey scale for assessing
staining
GB/T 6151 Textiles - Tests for colour fastness - General principle of testing
GB/T 6682 Water for analytical laboratory use - Specification and test
methods
GB/T 7568.1 Textiles - Tests for colour fastness - Specification for wool
adjacent fabric
GB/T 7568.2 Textiles - Tests for colour fastness - Standard adjacent fabrics
- Part 2: Cotton and viscose
GB/T 7568.3 Textiles - Tests for colour fastness - Standard adjacent fabrics
- Part 3: Polyamide
GB/T 7568.4 Textiles - Tests for colour fastness - Specification for polyester
adjacent fabric
GB/T 7568.5 Textiles - Tests for colour fastness - Specification for acrylic
adjacent fabric
Other devices which can achieve the same result can be used.
4.2 Thermostat
KEEP the temperature at (37±2) °C.
4.3 Artificial saliva
4.3.1 Formula composition
The reagents used are chemically pure. USE Grade 3 water (4.12) to prepare
the test solution. Prepared when used.
Each liter of test solution contains:
Magnesium chloride hexahydrate (MgCl2 • 6H2O) 0.17 g
Calcium chloride dihydrate (CaCl2 • 2H2O) 0.15 g
Dipotassium hydrogen phosphate trihydrate (K2HPO4 • 3H2O) 0.76 g
Potassium carbonate (K2CO3) 0.53 g
Sodium chloride (NaCl) 0.33 g
Potassium chloride (KCl) 0.75 g
USE hydrochloric acid solution with a mass fraction of 1% to adjust the pH of
the test solution to 6.8±0.1.
4.3.2 Preparation method
DISSOLVE the prescribed amount of sylvite and sodium salts in 900 mL of
Grade 3 water (4.12); ADD magnesium chloride and calcium chloride and stir
until they are completely dissolved. Immerse the calibrated pH meter (4.11)
electrode in the solution; ADD slowly 1% hydrochloric acid solution; STIR gently
to make the solution pH reach 6.8±0.1. ADD Grade 3 water (4.12) to dilute to
1000 mL; SHAKE well and store in the dark.
4.4 Adjacent fabric (See GB/T 6151)
Choose any one of 4.4.1 and 4.4.2.
4.4.1 A multifibre adjacent fabric shall conform to GB/T 7568.7.
4.4.2 Two single-fibre adjacent fabrics shall conform to GB/T 7568.1~7568.6,
GB/T 7568.8, GB/T 13765.
a) TAKE a piece of sample of (100±2)mm×(40±2)mm; CONTACT the front to
a piece of (100±2)mm×(40±2)mm multifibre adjacent fabric (4.4.1). Sew
along a short side to form a combined sample.
b) TAKE a piece of sample of (100±2)mm×(40±2)mm and sandwich it
between two (100±2)mm×(40±2)mm single-fibre adjacent fabrics (4.4.2).
Sew along a short side to form a combined sample.
5.2 For yarn or loose-fibre samples, the mass of yarn or loose fibre taken is
approximately equal to half the total mass of the adjacent fabric. According to
one of the following methods, prepare a combined sample:
a) SANDWICH it between a piece of (100±2)mm×(40±2)mm multifibre
adjacent fabric and a piece of (100±2)mm×(40±2)mm non-dyeable fabric
(4.4.3). Sew along the four sides (See GB/T 6151) to form a combined
sample.
b) SANDWICH it between two prescribed (100±2)mm×(40±2)mm single-fibre
adjacent fabrics. Sew along the four sides to form a combined sample.
6 Operating procedures
6.1 At room temperature, the combined sample is placed flat in a flat-bottomed
container (4.10). Inje......
Related standard:   GB/T 38473-2020
   
 
Privacy   ···   Product Quality   ···   About Us   ···   Refund Policy   ···   Fair Trading   ···   Quick Response