Powered by Google-Search & Google-Books Chinese Standards Shop Database: 169760 (Sep 19, 2020)
HOME   Quotation   Tax   Examples Standard-List   Contact-Us   View-Cart
  

GB50545-2010

Chinese Standard: 'GB50545-2010'
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusRelated Standard
GB 50545-2010English150 Add to Cart 0--15 minutes. Auto immediate delivery. Code for design of 110kV~750kV overhead transmission line Valid GB 50545-2010
GB 50545-2010Chinese79 Add to Cart <=1-day [PDF from Chinese Authority, or Standard Committee, or Publishing House]

  Google-Books (Full-PDF will be auto-delivered in 0~10 mins):   GB 50053-2013  GB 50545-2010  GB/T 50062-2008
In 0~10 minutes time, full copy of this English-PDF will be auto-immediately delivered to your email. See samples for translation quality.  
UDC
NATIONAL STANDARD
OF THE PEOPLE'S REPUBLIC OF CHINA
P GB 50545-2010
Code for Design of 110kV~750kV Overhead
Transmission Line
110kV~750kV架空输电线路设计规范
ISSUED ON. JANUARY 18, 2010
IMPLEMENTED ON. JULY 01, 2010
Jointly issued by. Ministry of Housing and Urban-rural Development;
General Administration of Quality Supervision, Inspection
and Quarantine of the People's Republic of China.
GB
Contents
1 General Provisions ... 1
2 Terms and Symbols ... 1
2.1 Terms ... 1
2.2 Symbols ... 2
3 Routing ... 4
4 Meteorological Conditions ... 5
5 Conductor and Earthwire... 7
6 Insulators and Fittings ... 10
7 Insulation Coordination, Lightning Protection and Grounding...11
8 Conductor Arrangement ... 16
9 Tower Type ... 17
10 Tower Load and Material ... 18
10.1 Tower Load... 18
10.2 Structural Material ... 24
11 Tower Structure ... 26
11.1 General Calculating Stipulation ... 26
11.2 Ultimate State Expression for Carrying Capacity and Serviceability ... 27
11.3 General Stipulation for Structure ... 28
12 Foundations ... 29
13 Ground Clearance and Crossing... 31
14 Environmental Protection... 38
15 Labor Safety and Industrial Sanitation ... 38
16 Accessories ... 39
Appendix A Typical Meteorological Area ... 40
Appendix B Classification of Overhead Line Pollution... 41
Appendix C Reference Value of m1 for Different Insulator Type... 42
Appendix D Horizontal Distance between Phases Depending on Span for Suspension Tower
... 44
Appendix E Calculating Density and Cone Angle of Soil for Uplift Foundation ... 45
Appendix F Classification of Telecommunication Line ... 46
Appendix G Classification of Road... 47
Explanation of Wording in this Code... 48
List of Quoted Standards ... 49
vi
11 General Provisions
1.0.1 In order to implement national capital construction policy and technical economy
policy during the design of AC 110kV~750kV overhead transmission line, achieve safety and
reliability, advanced application, economy and rationality, resource conservation and friendly
environment, this code is formulated.
1.0.2 This code is applicable to the design of AC 110kV~750kV overhead transmission line;
thereinto, AC 110kV~500kV is applicable to the design of single loop, same tower and double
loop as well as same tower multiple loop transmission line; AC 750kV is applicable to the
design of single loop transmission line.
1.0.3 The design of overhead transmission line shall start from practice, combine local
characteristic, positively adopt new technique, new process, new equipment and new material,
popularize and adopt advanced technology and product with energy conservation and
consumption reduction as well as environmental protection.
1.0.4 As for important line and special section line, the proper strengthening measures
should be adopted to improve security level of line.
1.0.5 This code specifies basic requirements of design of 110kV~750kV overhead
transmission line; if this code interferes with specifications in national laws, administrative
regulations, the national laws and administrative regulations shall be conformed to.
1.0.6 the design of overhead transmission line shall not only meet those specified in this
code, but also comply with those specified in the national current relevant standards.
2 Terms and Symbols
2.1 Terms
2.1.1 Overhead transmission line
It refers to the power line in which the insulator and tower are used to set the conductor
above the ground.
2.1.2 Telecommunication line
It refers to the communication line of various electrical signals.
2.1.3 Large crossing
It refers to the section that the conductor selection or tower design needs special
consideration owing to larger span (above 1000m) or higher tower (above 100m) when line
crossing navigation river, lake or strait and has a strong impact on navigation or especially
difficult repair during fault.
2.1.4 Light/medium/heavy icing area
The area with design ice coating thickness equal to 10mm and below is light icing area;
the area with design ice coating thickness larger than 10mm and less than 20mm is medium
icing area; the area with design ice coating thickness equal to 20mm and above is heavy icing
area
2.1.5 Reference wind speed
βc——the adjustment coefficient of wind load of conductor and earthwire;
βz——the adjustment coefficient of wind load of tower;
μs——the s......
Related standard:   GB/T 32576-2016  GB/T 32673-2016
   
 
Privacy   ···   Product Quality   ···   About Us   ···   Refund Policy   ···   Fair Trading   ···   Quick Response
Field Test Asia Limited | Taxed in Singapore: 201302277C | Copyright 2012-2020