HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (5 Oct 2024)

YY/T 1759-2020 PDF in English


YY/T 1759-2020 (YY/T1759-2020, YYT 1759-2020, YYT1759-2020)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
YY/T 1759-2020English410 Add to Cart 0-9 seconds. Auto-delivery. Guide for design and evaluation of primary flexible packaging for medical devices Valid
Standards related to (historical): YY/T 1759-2020
PDF Preview

YY/T 1759-2020: PDF in English (YYT 1759-2020)

YY/T 1759-2020 YY PHARMACEUTICAL INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.040.01 C 30 Guide for Design and Evaluation of Primary Flexible Packaging for Medical Devices ISSUED ON: SEPTEMBER 27, 2020 IMPLEMENTED ON: SEPTEMBER 1, 2021 Issued by: National Medical Products Administration Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative References ... 4  3 Terms and Definitions ... 8  4 Content, Method and Application of Design and Evaluation ... 9  Appendix A (informative) Test Methods for Packaging Design and Evaluation for Reference ... 14  Appendix B (informative) Information on Test Methods for Packaging Design and Evaluation ... 16  Guide for Design and Evaluation of Primary Flexible Packaging for Medical Devices 1 Scope This Standard provides a guide for design and evaluation of primary flexible packaging for medical devices. This Standard does not involve acceptability criteria. NOTE: the acceptability criteria are jointly determined by the packaging manufacturer and the medical device manufacturer. This Standard is applicable to the design and evaluation of primary flexible packaging of medical devices aseptically and non-aseptically provided. 2 Normative References The following documents are indispensable to the application of this document. In terms of references with a specified date, only versions with a specified date are applicable to this document. In terms of references without a specified date, the latest version (including all the modifications) is applicable to this document. GB/T 451.1 Paper and Board - Determination of Size and Deviation GB/T 451.2 Paper and Board - Determination of Grammage GB/T 451.3 Paper and Board - Determination of Thickness GB/T 454 Paper - Determination of Bursting Strength GB/T 455 Paper and Board - Determination of Tearing Resistance GB/T 458 Paper and Board - Determination of Air Permeance GB/T 464 Accelerated Aging (dry heat treatment) of Paper and Board GB/T 465.1 Paper and Board - Determination of Bursting Strength after Immersion in Water GB/T 465.2 Paper and Board - Determination of Tensile Strength after Immersion in Water GB/T 1037 Test Method for Water Vapor Transmission of Plastic Film and Sheet - Cup Method GB/T 7706 The Relief Prints for Decorating GB/T 7742 (all parts) Textiles - Bursting Properties of Fabrics GB/T 8807 Test Method for Specular Gloss of Plastics GB/T 8809 Pendulum Impact Resistance of Plastic Film GB/T 10006 Plastics - Film and Sheeting - Determination of the Coefficients of Friction GB/T 12914 Paper and Board - Determination of Tensile Properties - Constant Rate of Elongation Method (20 mm/min) GB/T 15171 Test Method for Leaks in Sealed Flexible Packages GB/T 16578 (all parts) Plastics - Film and Sheeting - Determination of Tear Resistance GB/T 16886 (all parts) Biological Evaluation of Medical Devices GB/T 17593 (all parts) Textiles - Determination of Heavy Metals GB/T 19633.1 Packaging for Terminally Sterilized Medical Devices - Part 1: Requirements for Materials, Sterile Barrier Systems and Packaging Systems GB/T 19789 Packaging Materials - Test Method for Oxygen Gas Permeability Characteristics of Plastic Film and Sheeting - Coulometric Sensor GB/T 21529 Determination of Water Vapor Transmission Rate for Plastic Film and Sheeting - Electrolytic Detection Sensor Method GB/T 22819 High Permeable Paper - Determination of Air Permeability GB/T 22895 Paper and Board - Determination of the Static and Kinetic Coefficients of Friction - Horizontal Plane Method GB/T 22898 Paper and Board - Determination of Tensile Properties - Constant Rate of Elongation Method (100 mm/min) GB/T 22901 Paper and Board - Determination of Air Permeance (medium range) - General Method GB/T 22921 Paper and Board - Determination of Water Vapor Transmission Rate of Sheet Materials - Dynamic Sweep and Static Gas Methods GB/T 24218.1 Textiles - Test Methods for Nonwovens - Part 1: Determination of Mass per Unit Area GB/T 24218.2 Textiles - Test Methods for Nonwovens - Part 2: Determination of Thickness YY/T 0698.6 Packaging Materials for Terminal Sterilized Medical Devices - Part 6: Paper for Manufacture of Sterile Barrier Systems Intended for Sterilization by Low Temperature Sterilization Processes or Irradiation - Requirements and Test Methods YY/T 0698.7 Packaging Materials for Terminal Sterilized Medical Devices - Part 7: Adhesive Coated Paper for the Manufacture of Sealable Packs for Medical Use for Sterilization by Ethylene Oxide or Irradiation - Requirements and Test Methods YY/T 1286.1 Platelets Storage Container Performances - Part 1: Determination of Gas Permeability of the Film - Differential-pressure Method YY/T 1432 Test Method for Determination of Heat-sealability of Flexible Webs of Medical Devices as Measured by Seal Strength YY/T 1433 Test Method of Hot Seal Strength (hot tack) of Flexible Webs of Medical Devices ISO 6588 (all parts) Paper, Board and Pulps - Determination of pH of Aqueous Extracts ISO 7765-1 Plastics Film and Sheeting - Determination of Impact Resistance by the Free-falling Dart Method - Part 1: Staircase Methods ISO 9197 Paper, Board and Pulps - Determination of Water-soluble Chlorides ISO 15105 (all parts) Plastics - Film and Sheeting - Determination of Gas-transmission Rate 3 Terms and Definitions The following terms and definitions are applicable to this document. 3.1 Barrier Requirements Barrier requirements refer to the demand to promote or restrict moisture, gas, light or combinations thereof to maintain the necessary level of sterility. 3.2 Durability Requirements Durability requirements refer to the material characteristics related to the ability of the package to protect the product. 3.3 Integrity and Seal Requirements Integrity and seal requirements refer to the ability of the package to prevent accidental dropping of the contents or entry of foreign substances when the package is not opened for use. 4.2 Method of Design and Evaluation When a medical device is characterized and the sterilization method is determined, then, there are many specific requirements for its packaging. This Standard provides guidelines for the selection of test methods for the evaluation of these requirements, the packaging research and development stage and the routine control. NOTE: product characterization includes quality or weight, geometric shape (length, width, height and shape) and product composition. 4.3 Description and Application of Test Methods 4.3.1 General principles Table 1 provides the test methods available for various evaluations suitable for the research and development stage, and routine control. The provided test methods are not a test list. The appropriate test method needs to be selected in accordance with the specific packaging. Other test methods beyond Table 1 may also need to be selected. NOTE: see Appendix A for information on some of the available test methods. Please refer to Appendix B for the description and application of the various test methods in Table 1. 4.3.2 Tests of packaging research and development stage Tests of the packaging research and development stage are used to generate quantitative data on the properties of materials and components. Some test methods take a long time and are not suitable for process control that requires rapid response; some test methods are expensive and require special test instruments. 4.3.3 Tests of routine control Tests of routine control need to be fast, low-cost and easy to carry out in a production environment. The purpose is not to develop design data, but to ensure that the design specifications are satisfied. These test methods are not necessarily used to directly measure the critical values; they may also be used to detect changes in materials, processes or key characteristics of the product. 4.3.4 Special consideration The multiple test methods provided in this Standard are not necessarily applicable to a specific medical device packaging. The selection of a specific test method shall be based on the relevant characteristics of the medical device product and the purpose of the test (such as: the research and development stage, and routine control). The users of this Standard need to consider the applicability of various items and test methods. ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.