HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (10 May 2025)

PDF YY/T 1704.1-2020 English


Search result: YY/T 1704.1-2020
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
YY/T 1704.1-2020English125 Add to Cart 0-9 seconds. Auto-delivery. Cervical dilator for single use - Part 1: Gradual dilator Valid

PDF Preview: YY/T 1704.1-2020                   
      

YY/T 1704.1-2020: PDF in English (YYT 1704.1-2020)

YY/T 1704.1-2020 YY PHARMACEUTICAL INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.040.30 C 36 Cervical dilator for single use - Part 1: Gradual dilator ISSUED ON: FEBRUARY 21, 2020 IMPLEMENTED ON: JANUARY 01, 2021 Issued by: National Medical Products Administration Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative references ... 4  3 Classification ... 4  4 Requirements ... 6  5 Test methods ... 7  6 Marks, packaging and instruction manual ... 9  7 Transport, storage ... 9  Cervical dilator for single use - Part 1: Gradual dilator 1 Scope This Part of YY/T 1704 specifies the classification, requirements, test methods, marks, packaging and instruction manual, transport, storage and sterilization period for gradual cervical dilator for single use (hereinafter referred to as the dilator). This Part is applicable to cervical dilator for single use. This product is used for dilatation of the cervix in obstetrics and gynecology and family planning departments. This Part is not applicable to the cervical dilator made of metal. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 14233.1-2008, Test methods for infusion transfusion injection equipment for medical use - Part 1: Chemical analysis methods GB/T 16886.1, Biological evaluation of medical devices - Part 1: Evaluation and testing YY/T 0171, Surgical instruments - Packaging, Marking and Instructions Pharmacopoeia of the People's Republic of China (2015 Edition) Part IV 3 Classification 3.1 Type 3.1.1 The dilator is the expansion section within 60mm of the ring line from the head end. It is usually composed of 3 gradual units. Each unit is about 20mm long. 4 Requirements 4.1 Appearance 4.1.1 The head of the dilator shall be round and smooth, and no fibers shall be pulled out. 4.1.2 The marks of the dilator shall be clear and obvious. 4.1.3 The overall dilator shall be smooth and uniform in color, and there shall be no cracks, burrs, plastic flow, or defects. 4.2 Dimensions The gradual diameter range d1 and d2 of the dilator, the tilt angle θ of the tip shall meet the requirements of Table 1. 4.3 Physical properties 4.3.1 The dilator shall be able to withstand 50N axial tension without breaking. 4.3.2 Apply a force of 15N to the head of the dilator, and there shall be no obvious deformation or fracture. NOTE: Obvious deformation can be understood as the tip tilt angle θ≤0° after applying force. 4.4 Chemical properties 4.4.1 Heavy metals The total content of heavy metals in the dilator test solution shall not exceed 1μg/mL. 4.4.2 PH Compare the dilator test solution with the blank solution. The difference in pH shall not exceed 1.5. 4.4.3 UV absorbance The absorbance of the dilator test solution in the wavelength range of 250nm~320nm shall not exceed 0.1. 4.5 Sterilization The dilator shall be sterilized by a confirmed sterilization process, and the sterilized dilator shall be sterile. NOTE: N is the loading force. Figure 2 -- Schematic diagram of bending performance test of the dilator 5.4 Chemical properties 5.4.1 Test solution preparation Take sample. Add water at a ratio: 0.2g of sample to 1mL of water. Keep constant temperature at (37±1)°C for 8h. Separate the sample from water. Cool to room temperature as the test solution. Take the same volume of water and place it in a glass container. Prepare blank control solution in the same way. 5.4.2 Heavy metals Test according to the method specified in 5.6.1 of GB/T 14233.1-2008, in accordance with the requirements of 4.4.1. 5.4.3 PH Test according to the method specified in 5.4.1 of GB/T 14233.1-2008, in accordance with the requirements of 4.4.2. 5.4.4 UV absorbance Test according to the method specified in 5.7 of GB/T 14233.1-2008, in accordance with the requirements of 4.4.3. 5.5 Sterilization The inspection is carried out in accordance with the method stipulated in the fourth part 1101 sterile inspection method of the "Pharmacopoeia of the People's Republic of China" (Edition 2015), in accordance with the requirements of 4.5. NOTE: Each sterilization batch undergoes an effective monitoring process to make the product sterile. 5.6 Residual ethylene oxide Test according to the method in Clause 9 of GB/T 14233.1-2008, in accordance with the requirements of 4.6. 5.7 Biological evaluation Evaluate according to the corresponding method of biological evaluation, in accordance with the requirements of 4.7. ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.

Similar standards: YY/T 1777   YY/T 1783   YY/T 1704.2   YY/T 1850