HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (8 Feb 2025)

YY/T 1550.2-2019 PDF English


Search result: YY/T 1550.2-2019 English: PDF (YY/T1550.2-2019)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
YY/T 1550.2-2019English115 Add to Cart 0-9 seconds. Auto-delivery. Guidance of study on the compatibility of infusion equipments and pharmaceutical products - Part 2: Leachable known - Substance Valid
BUY with any currencies (Euro, JPY, GBP, KRW etc.): YY/T 1550.2-2019     Related standards: YY/T 1550.2-2019

PDF Preview: YY/T 1550.2-2019


YY/T 1550.2-2019: PDF in English (YYT 1550.2-2019)

YY/T 1550.2-2019 YY PHARMACEUTICAL INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.040.30 C 31 Guidance of study on the compatibility of infusion equipment and pharmaceutical products - Part 2: Leachable known - Substance ISSUED ON: JULY 24, 2019 IMPLEMENTED ON: AUGUST 01, 2020 Issued by: National Medical Products Administration Table of Contents Foreword ... 3  Introduction ... 4  1 Scope ... 5  2 Normative references ... 5  3 Terms and definitions ... 5  4 Test methods ... 6  5 Content of study report ... 9  Guidance of study on the compatibility of infusion equipment and pharmaceutical products - Part 2: Leachable known - Substance 1 Scope This Part of YY/T 1550 gives the method for study on known leachable substance in the process of single-use infusion equipment in contact with pharmaceutical products under clinical infusion conditions or simulated clinical actual infusion conditions. This Part applies to the study of known leachable substance with specific infusion equipment and pharmaceutical product to be infused or a simulated solvent selected after demonstration. 2 Normative references The following documents are indispensable for the application of this document. For the dated references, only the editions with the dates indicated are applicable to this document. For the undated references, the latest edition (including all the amendments) are applicable to this document. GB/T 16886.12-2017 Biological evaluation of medical devices - Part 12: Sample preparation and reference materials Pharmacopeia of the People's Republic of China (2015) 3 Terms and definitions The following terms and definitions apply to this document. 3.1 Leachable substance The substance which can be released from a medical device or material during clinical use. [GB/T 16886.12-2017, definition 3.10] 3.2 the greatest risk to the patient in the intended use of the product. 4.1.2 Methods for preparation of extract liquid 4.1.2.1 Preparation of extract liquid using drug Take the equipment and drugs to be studied; according to the common infusion method given in the drug instruction manual or clinical investigation, prepare the extract liquid. Preparation parameters need to consider the dosage, infusion carrier (such as sodium chloride injection, glucose injection, etc.), dilution method, infusion method (such as gravity drip, infusion pump administration, administration from injection parts) , infusion rate, infusion temperature. If necessary, use clinically applicable infusion carrier to prepare 3 parts of drug infusion liquid in line with clinical practice. Among which, infuse 2 of the infusion liquids through the infusion equipment according to the common infusion methods given in the drug instruction manual or clinical investigation; collect the effluent as the test solution. Another prepared drug infusion liquid is stored under the same conditions for the same time as the drug control solution. 4.1.2.2 Preparation of extract liquid using alternative solvents If simulated-use extraction is performed, it shall comprehensively consider the parameters and conditions of the medical device in actual clinical use, such as time, temperature, mode of action, etc. First, the preparation method of extract liquid shall be demonstrated, to prove that the extraction conditions selected by the device represent the greatest risk to the patient in the intended use of the product. The selection of simulated solvent shall comprehensively consider other characteristics such as the polarity and pH of the device to be studied in clinical contact with pharmaceutical product. 4.2 Study on known leachable substance 4.2.1 Methodological investigation items 4.2.1.1 Overview Confirmed test methods should be used to determine known substances in leachables. Generally, methods recommended by national standards or industry standards or methods of determination that have been peer-reviewed are preferred. At present, the commonly-used analytical methods mainly include HPLC, LC-MS, GC-MS, GC, AAS, and ICP-MS. The first four methods are mainly used to evaluate organic leachable substance. The latter two methods are mainly used for the qualitative and quantitative determination of inorganic migratory substances, especially metal elements. 4.2.1.2 Specificity Excipients in pharmaceutical preparations, related substances, infusion carriers in the preparation of extract liquid, and potential soluble substances in infusion equipment may interfere with the determination of the dissolution amount of the analyte. Appropriate methods should be used to verify specificity. 4.2.1.3 Linear range Linearity refers to the degree to which the measured response value is proportional to the concentration of the analyte in the sample within the designed range. The range refers to the range of high-low concentrations or quantities when the analytical method can achieve certain precision, accuracy and linearity requirements. The selected method shall ensure that the concentration in the sample to be tested is within its linear range. At the same time, the setting of the range shall consider the toxicological evaluation value. It is recommended to use at least 5 concentrations. 4.2.1.4 Detection limit The detection limit refers to the minimum amount of the analyte in the sample that can be detected. The detection limit of the method shall meet the requirements of toxicological evaluation value of the analyte. Appropriate methods shall be used to examine the detection limit. It shall meet the requirements of its toxicological evaluation value. The evaluation method should be carried out in accordance with "Pharmacopeia of the People's Republic of China" (2015) Volume IV 9101. 4.2.1.5 Quantitation limit The quantification limit refers to the minimum amount of the analyte in the sample that can be quantitatively determined. The determination results shall meet the requirements of accuracy and precision. Appropriate methods shall be used to examine the quantification limit. The evaluation method should be carried out in accordance with "Pharmacopeia of the People's Republic of China" (2015) Volume IV 9101. 4.2.1.6 Precision Appropriate methods should be used to examine the precision of the proposed method for determination of the content. The evaluation method should be carried out in accordance with "Pharmacopeia of the People's Republic of China" (2015) Volume IV 9101. 4.2.1.7 Accuracy Appropriate methods should be used to verify the accuracy of the results. Take the standard-addition recovery test as an example; add a quantitative standard substance to the blank sample matrix without the tested substance; according ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.