HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (3 Nov 2024)

YY/T 1525-2017 PDF in English


YY/T 1525-2017 (YY/T1525-2017, YYT 1525-2017, YYT1525-2017)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
YY/T 1525-2017English115 Add to Cart 0-9 seconds. Auto-delivery. Test kit for methamphetamine (colloidal gold method) Valid
Standards related to (historical): YY/T 1525-2017
PDF Preview

YY/T 1525-2017: PDF in English (YYT 1525-2017)

YY/T 1525-2017 YY PHARMACEUTICAL INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.100 C 44 Test Kit for Methamphetamine (Colloidal Gold Method) ISSUED ON. MAY 02, 2017 IMPLEMENTED ON. APRIL 01, 2018 Issued by. China Food and Drug Administration Table of Contents Foreword ... 3 1 Scope ... 4 2 Normative References ... 4 3 Terms and Definitions ... 4 4 Requirements ... 5 5 Test Methods ... 6 6 Mark, Label, Use Instructions ... 8 7 Package, Transportation and Storage ... 8 Bibliography ... 9 Test Kit for Methamphetamine (Colloidal Gold Method) 1 Scope This Standard specifies the terms and definitions, requirements, test methods, mark, label, use instructions, package, transportation and storage of test kit for methamphetamine (colloidal gold method). This Standard is applicable to the detection kit for the qualitative detection of methamphetamine (MET) in human urine and the combined detection kit containing methamphetamine by the principle of colloidal gold immunochromatography. This Standard is not applicable to. a) The detection kit for non-human urine test; b) Kits tested by other methods. 2 Normative References The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this document. GB/T 191-2008 Packaging – Pictorial Marking for Handling of Goods GB/T 29791.2-2013 In Vitro Diagnostic Medical Devices - Information Supplied by the Manufacturer (Labelling) - Part 2. In Vitro Diagnostic Reagents for Professional Use 3 Terms and Definitions The following terms and definitions are applicable to this document. 3.1 Methamphetamine CAS No.. 537-46-2; molecular formula. C10H15N; also called desoxyephedrine The kit is stored under the specified conditions unit the end of the shelf life; test the physical properties, positive reference product compliance rate, negative reference product compliance rate, minimum detection limit, repeatability; the results shall conform to the provisions of 4.1, 4.2, 4.3, 4.4 and 4.5. b) Thermal stability test Place the kit under the specified conditions (generally 37°C) for a specified period of time (generally 21d); test the physical properties, positive reference product compliance rate, negative reference product compliance rate, minimum detection limit, repeatability; the results shall conform to the provisions of 4.1, 4.2, 4.3, 4.4 and 4.5. NOTE 1. Thermal stability cannot be used to derive the valid date of the product; unless it is from a derivation formula based on a large number of stability studies. NOTE 2. According to the product characteristics, one of the above methods a) or b) can be selected for verification; but the selected method shall be able to verify the stability of the product to ensure that the product performance meets the standard requirements during the shelf life. 5 Test Methods 5.1 Physical properties 5.1.1 Appearance Take visual examination with normal or corrected visual acuity under natural light, the results shall meet the requirements of 4.1.1. 5.1.2 Width of membrane strip Randomly take a strip of membrane strip from the kit; test with the measuring ruler; the results shall meet the requirements of 4.1.2. 5.1.3 Liquid migration speed Operate as per the instructions; add sample liquid from the sampling loading area of the kit; start timing when the liquid is moved to the reaction zone; stop timing when the liquid is moved to the end of the reaction zone; the used time is t; use the Vernier caliper to measure the length of the reaction zone, which is recorded as L; calculate the L/t, which is migration speed; the results shall meet the requirements of 4.1.3. 5.2 Positive reference product compliance rate Test once with a national positive reference product or a standardized positive ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.