HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (17 May 2025)

PDF YY/T 1517-2017 English


Search result: YY/T 1517-2017
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
YY/T 1517-2017English90 Add to Cart 0-9 seconds. Auto-delivery. Detection kit for IgA antibody to epstein-barr viral capsid antigens Valid

PDF Preview: YY/T 1517-2017                   
      

YY/T 1517-2017: PDF in English (YYT 1517-2017)

YY/T 1517-2017 YY PHARMACEUTICAL INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.100 C 44 Detection Kit for IgA Antibody to Epstein-barr Viral Capsid Antigens ISSUED ON. MAY 2, 2017 IMPLEMENTED ON. APRIL 1, 2018 Issued by. China Food and Drug Administration Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative References ... 4  3 Terms and Definitions ... 4  4 Test Methods ... 6  5 Label and Instruction for Use ... 7  6 Packaging, Transportation and Storage ... 7  References ... 9  Detection Kit for IgA Antibody to Epstein-barr Viral Capsid Antigens 1 Scope This Standard specifies the technical requirements, test methods, label, instruction for use, packaging, transportation and storage of detection kit for IgA antibody to Epstein- barr viral capsid antigens (hereinafter referred to as “detection kit”). This Standard is applicable to detection kit that qualitatively detects IgA antibody to Epstein-Barr viral capsid antigens in human serum/plasma in accordance with the principle of enzyme linked immunosorbent assay, chemiluminescence and time- resolved fluorescence. 2 Normative References The following documents are indispensable to the application of this Standard. In terms of references with a specified date, only versions with a specified date are applicable to this Standard. The latest version (including all the modifications) of references without a specified date is also applicable to this Standard. GB/T 191 Packaging - Pictorial Marking for Handling of Goods GB/T 29791.2 In-vitro Diagnostic Medical Devices - Information Supplied by the Manufacturer (Labelling) - Part 2. In-vitro Diagnostic Reagents for Professional Use 3 Terms and Definitions 3.1 Appearance Appearance shall comply with the following requirements. a) The various components of detection kit shall be complete and intact; there shall be no liquid leakage; b) Chinese labels on the package shall be explicit; there shall be no abrasion. 3.2 Positive Reference Compliance Rate National-level positive reference or standardized positive reference shall be adopted for detection, and the result shall comply with corresponding requirements. NOTE 3. In accordance with product characteristics, any combination of Method a) and Method b) can be selected. However, the selected method shall be able to verify products’ stability, which can guarantee that products’ performance can comply with standard requirements within the validity. 4 Test Methods 4.1 Appearance Conduct visual inspection with normal vision or corrected vision under the natural light; the result shall comply with the requirement in 3.1. 4.2 Positive Reference Compliance Rate National-level positive reference or standardized positive reference shall be adopted for detection; operate in accordance with the instruction for use; the result shall comply with the requirement in 3.2. 4.3 Negative Reference Compliance Rate National-level negative reference or standardized negative reference shall be adopted for detection; operate in accordance with the instruction for use; the result shall comply with the requirement in 3.3. 4.4 Minimum Detection Limit National-level minimum detection limit reference or standardized minimum detection limit reference shall be adopted for detection; operate in accordance with the instruction for use; the result shall comply with the requirement in 3.4. 4.5 Repeatability Take the same batch of detection kit; national-level repeatability reference or standardized repeatability reference shall be adopted for 10 repeated detection. Calculate the average value and standard deviation of the 10 detections. Calculate the coefficient of variation CV in accordance with Formula (1) below. The result shall comply with the requirement in 3.5 Where. CV---Coefficient of variation; ---Standard deviation; ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.

Similar standards: YY/T 1516   YY/T 1518   YY/T 1515   YY/T 1514