YY/T 1474-2016 PDF in English


YY/T 1474-2016 (YY/T1474-2016, YYT 1474-2016, YYT1474-2016)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
YY/T 1474-2016English1210 Add to Cart 0-9 seconds. Auto-delivery. Medical devices-Application of risk management to medical devices Valid
Standards related to (historical): YY/T 1474-2016
PDF Preview

YY/T 1474-2016: PDF in English (YYT 1474-2016)

YY/T 1474-2016 YY PHARMACEUTICAL INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.040 C 30 YY/T 1474-2016 / IEC 62366:2007 Medical Devices - Application of Usability Engineering to Medical Devices (IEC 62366:2007, IDT) ISSUED ON: JANUARY 26, 2016 IMPLEMENTED ON: JANUARY 01, 2017 Issued by: China Food and Drug Administration Table of Contents Foreword ... 4 Introduction ... 5 1* Scope ... 6 2 Normative References ... 6 3 Terms and Definitions ... 6 4* Principles ... 11 4.1 General requirements ... 11 4.1.1* USABILITY ENGINEERING PROCESS ... 11 4.1.2 RESIDUAL RISK ... 12 4.1.3 Information for SAFETY ... 12 4.2* USABILITY ENGINEERING FILE ... 13 4.3 Scaling of the USABILITY ENGINEERING effort ... 13 5* Usability Engineering Process ... 14 5.1* Application specification ... 14 5.2* Frequently used functions ... 14 5.3 Identification of HAZARDS and HAZARDOUS SITUATIONS related to USABILITY ... 15 5.3.1 Identification of characteristics related to SAFETY ... 15 5.3.2* Identification of known or foreseeable HAZARDS and HAZARDOUS SITUATIONS ... 15 5.4 PRIMARY OPERATING FUNCTIONS ... 16 5.5* USABILITY SPECIFICATION ... 17 5.6 USABILITY VALIDATION plan ... 18 5.7* USER INTERFACE design and implementation ... 19 5.8* USABILITY VERIFICATION ... 19 5.9* USABILITY VALIDATION ... 20 6* Accompanying Document ... 21 7 * Training and Materials for Training ... 21 Annex A (Informative) General Guidance and Rationale ... 23 Annex B (Informative) Categories of USER Action ... 39 Annex C (Informative) Examples of USE ERRORS, ABNORMAL USE and Possible Causes ... 41 Annex D (Informative) Guidance on the USABILITY ENGINEERING PROCESS ... 45 Annex E (Informative) Questions that can be Used to Identify MEDICAL DEVICE Characteristics Associated with USABILITY that could Impact on SAFETY ... 78 Annex F (Informative) Examples of Possible USABILITY Related HAZARDOUS SITUATIONS ... 83 Annex G (Informative) USABILITY goals: Illustrative Example for a Home Parenteral Infusion Pump ... 86 Annex H (Informative) Sample USABILITY SPECIFICATION and its Inputs . 98 Annex I (Informative) Recommended Reading List... 114 Annex J (Informative) Reference to the Essential Principles ... 124 Bibliography ... 125 Index of Defined Terms ... 128 Foreword This Standard was drafted as per the rules specified in GB/T 1.1-2009. This Standard used the translation method to equivalently adopt IEC 62366:2007 Medical Devices – Application of Usability Engineering to Medical Devices. Terms are shown in bold in this Standard. The clauses and articles with an asterisk (*) in this Standard have explanations on their reasons in Annex A. Please note some contents of this Document may involve patents. The issuing agency of this Document does not assume the responsibility to identify these patents. This Standard was proposed by China Food and Drug Administration. This Standard shall be under the jurisdiction of Management Centre of the Standards for Medical Devices, China Food and Drug Administration. Drafting organizations of this Standard: Beijing Hua Guang Certification of Medical Devices Co., Ltd.; and Shanghai Testing & Inspection Institute for Medical Devices. Chief drafting staffs of this Standard: Wang Huifang, Mi Lanying, He Jun, Lu E, Zheng Yihan, and Chen Zhigang. Medical Devices - Application of Usability Engineering to Medical Devices 1* Scope This Standard specifies a PROCESS for a MANUFACTURER to analyse, specify, design, VERIFY and VALIDATE USABILITY, as it relates to SAFETY of a MEDICAL DEVICE. This USABILITY ENGINEERING PROCESS assesses and mitigates RISKS caused by USABILITY problems associated with CORRECT USE and USE ERRORS, i.e., NORMAL USE. It can be used to identify but does not assess or mitigate RISKS associated with ABNORMAL USE. NOTE: For the purposes of this standard, USABILITY (see 3.17) is limited to characteristics of the USER INTERFACE. If the USABILITY ENGINEERING PROCESS detailed in this Standard has been complied with and the acceptance criteria documented in the USABILITY VALIDATION plan have been met (see 5.9), then the RESIDUAL RISKS, as defined in ISO 14971, associated with USABILITY of a MEDICAL DEVICE are presumed to be acceptable, unless there is OBJECTIVE EVIDENCE to the contrary (see 4.1.2). This Standard does not apply to clinical decision-making relating to the use of a MEDICAL DEVICE. 2 Normative References The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) is applicable to this document. NOTE: Informative references are listed in the “Bibliography”. YY/T 0316-2016 Medical Devices – Application of Risk Management to Medical Devices (ISO 14971:2007 revised edition, IDT) 3 Terms and Definitions For the purpose of this document, the terms and definitions given in YY/T 0316-2016 and the following apply. ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.