YY/T 1160-2009 (YY/T 1160-2021 Newer Version) PDF English


Search result: YY/T 1160-2009 (YY/T 1160-2021 Newer Version)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
YY/T 1160-2021English159 Add to Cart 3 days Carcinoembryonic antigen testing kit Valid
YY/T 1160-2009English135 Add to Cart 0-9 seconds. Auto-delivery. Carcinoembryonic Antigen Quantitative Detection Reagent (Kit) (Chemiluminescent Immunoassay) Obsolete
BUY with any currencies (Euro, JPY, GBP, KRW etc.): YY/T 1160-2021     Newer version: YY/T 1160-2021

PDF Preview: YY/T 1160-2009


YY/T 1160-2009: PDF in English (YYT 1160-2009)

YY/T 1160-2009 YY ICS 11.100 C 44 PHARMACEUTICAL INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA Carcinoembryonic Antigen Quantitative Detection Reagent (Kit) (Chemiluminescent Immunoassay) ISSUED ON. DECEMBER 30, 2009 IMPLEMENTED ON. JUNE 1,2011 Issued by. State Food and Drug Administration Table of Contents Foreword ... 3  1  Scope ... 4  2  Normative references ... 4  3  Terms and definitions ... 4  4  Classifications ... 6  5  Requirements ... 6  6  Test methods ... 7  7  Product inspection rules ... 9  8  Marks, labels and instructions ... 10  9  Packaging, transportation and storage ... 12  Bibliography ... 13  Foreword  The preparation of this Standard follows the basic regulations of the GB/T 1.1-2000 Directives for Standardization. Part 1. Rules for the Structure and Preparation of Standards. It is the basis for evaluating the product quality of carcinoembryonic antigen quantitative determination reagent (kit) (chemiluminescent immunoassay). This Standard was proposed by the China Food and Drug Administration. This Standard shall be under the jurisdiction of the National Medical Clinical Testing Laboratory and In Vitro Diagnostic System Standardization Technical Committee (SAC/TC 136). Participating drafting organizations of this Standard. Beijing Institute of Medical Device Testing, Beijing Chemclin Biotech Co., Ltd., Beijing Yuande Biomedical Engineering Co., Ltd., Roche Diagnostic Products (Shanghai) Co., Ltd., and Beckman Coulter Co., Ltd. Main drafters of this Standard. Zhang Xinmei, Cheng Yinghao, Sun Xudong, Hu Guomao, Ying Xitang, Cai Xiaorong, and Zhang Jinwen. Carcinoembryonic Antigen Quantitative Detection Reagent (Kit) (Chemiluminescent Immunoassay) 1  Scope  This Standard specifies the terms and definitions, classification, requirements, test methods, inspection rules, marks, labels, operating instructions, packaging, transportation, and storage of carcinoembryonic antigen (CEA) quantitative determination reagent (kit) (chemiluminescent immunoassay). This Standard applies to the quantitative determination of human carcinoembryonic antigen (CEA) quantitative detection reagent (kit) (hereinafter referred to as "CEA reagent (kit)") based on the principle of chemiluminescent immunoassay. It includes enzymatic and non-enzymatic chemiluminescent immunoassay detection reagent (box) with carriers such as microplates, pipes, magnetic particles, microbeads, and plastic beads. The Standard is not applicable to the requirements to the calibration products and quality control products in the kit. 2  Normative references  The articles contained in the following documents have become part of this Standard when they are quoted herein. For the dated documents so quoted, all the modifications (excluding corrections) or revisions made thereafter shall not be applicable to this Standard. For the undated documents so quoted, the latest editions shall be applicable to this Standard. GB/T 21415-2008 In vitro diagnostic medical devices - Measurement of quantities in biological samples - Metrological traceability of values assigned to calibrators and control materials (ISO 17511.2003, IDT) 3  Terms and definitions  For the purpose of this Standard, the following terms and definitions apply. 3.1 Chemiluminescence, CL It refers to the luminescence phenomenon – because the chemical reaction can generate the substances of which the electronic energy level is in the excited state; the electrons can generate photons and release energy through transition; therefore it causes the luminescence CALCULATE the mean. USE the Least Square Method to perform the straight-line fitting for the results’ mean and dilution proportion. CALCULATE the linear correlation coefficient r. The result shall comply with the requirements of 5.5. 6.6 Repeatability Each sample of 10ng/mL±2ng/mL and 100ng/mL±20ng/mL is repeatedly tested for 10 times. CALCULATE the mean M and standard deviation SD of the 10 measurement results. Coefficient of variation CV is calculated from Equation of CV=SD/M×100%. The results shall comply with the requirements of 5.6. 6.7 Difference between batches Repeatedly USE 3 batches of kits to test the same-sample with concentration of 100ng/mL±20ng/mL for 10 times. CALCULATE the mean M and standard deviation SD of 30-times measurement results. CALCULATE the coefficient of variation CV from Equation CV=SD/M×100%. The results shall comply with the requirements of 5.7. 6.8 Stability a) Stability within the validity. TAKE the after-expired sample. PERFORM the detection according to the methods of 6.3, 6.4, 6.5 and 6.6. It shall comply with the requirements of 5.8 a). b) Thermal stability test. TAKE the within-validity sample. PLACE for 3 days at 37°C. PERFORM the detection according to the methods of 6.3, 6.4, 6.5 and 6.6. It shall comply with the requirements of 5.8 b). 7  Product inspection rules  7.1 General provisions CEA reagent (kit) must be submitted for inspection in batches. Inspection is divided into ex-factory inspection and type inspection. 7.2 Reagent (kit) must be delivered to the Quality Inspection Department for inspection. It can be sold only after inspection is qualified. 7.3 Reagent (kit) must be submitted for ex-factory inspection in batches. Each material-feeding batch is deemed as 1 batch of products. 7.4 Ex-factory inspection 7.4.1 Amount of sampling The amount of sampling of ex-factory inspection shall be 3 times of the amount of inspection items, including the amount of inspection, amount of re-inspection and the amount of retained sample. b) Name, address and contact information of manufacturing enterprise; c) Medical device registration certificate number and product standard number; d) Product batch number; e) Period of validity; f) Storage conditions. 8.2 Each constituent of reagent (kit) It shall contain at least the following contents. a) Product name and specifications; b) Name or marks of manufacturing enterprise; c) Product batch number; d) Period of validity. 8.3 Operating instructions of reagent (kit) It shall contain at least the following contents. a) Product name; b) Packaging specifications; c) Intended use; d) Inspection principle; e) Main compositions; f) Storage conditions and period of validity; g) Applicable instrument; h) Sample requirements; i) Inspection methods; j) Reference value (reference range); k) Interpretation of the inspection results; l) Limitations of inspection methods; Bibliography  1) GB/T 191 Packaging - Pictorial marking for handling of goods 2) GB/T 9969 General principles for preparation of instructions for use of industrial products 3) YY 0466-2003 Medical devices - Symbols to be used with medical device labels labelling and information to be supplied (ISO 15223-2000, IDT) 4) GB/T 19702-2005 In vitro diagnostic medical devices - Measurement of quantities in samples of biological origin - Requirements for content and presentation of reference measurement procedures (ISO 15193.2002, IDT) 5) ISO/DIS 18113-1 Clinical laboratory testing and in vitro diagnostic medical systems - Information supplied by the manufacturer (labelling) - Part 1. Terms, definitions and general requirements ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.