YY/T 1141-2017 PDF in English
YY/T 1141-2017 (YY/T1141-2017, YYT 1141-2017, YYT1141-2017)
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Name of Chinese Standard | Status |
YY/T 1141-2017 | English | 150 |
Add to Cart
|
0-9 seconds. Auto-delivery.
|
General technique requirements for osteotome
| Valid |
Standards related to (historical): YY/T 1141-2017
PDF Preview
YY/T 1141-2017: PDF in English (YYT 1141-2017) YY/T 1141-2017
YY
PHARMACEUTICAL INDUSTRY STANDARD
OF THE PEOPLE’S REPUBLIC OF CHINA
ICS 11.040.40
C 35
Replacing YY/T 91141-1999, YY 91071~91073-1999
General technique requirements for osteotome
ISSUED ON. SEPTEMBER 25, 2017
IMPLEMENTED ON. OCTOBER 1, 2018
Issued by. China Food and Drug Administration
Table of Contents
Foreword ... 3
1 Scope ... 5
2 Normative references ... 5
3 Terms and definitions ... 5
4 Requirements ... 5
5 Test methods ... 7
6 Marking ... 8
References ... 9
Foreword
This Standard is drafted in accordance with the rules given in GB/T 1.1-2009.
This Standard replaces YY/T 91141-1999 “General technical conditions for
osteotomes”, YY 91071-1999 “Osteotomes”, YY 91072-1999 “Gouges”, and
YY 91073-1999 “Methods of test for cutting performance of chisels -
Osteotomes Gouges”. As compared with YY/T 91141-1999, YY 91071-1999,
YY 91072-1999, and YY 91073-1999, the main technical changes are as
follows.
- MODIFY the requirements for material of osteotome;
- MODIFY hardness requirements;
- DELETE the surface finish requirement of osteotome, and CHANGE to the
surface roughness requirement;
- MODIFY the use performance method of osteotome;
- DELETE the requirements for inspection rules, packaging, transport, and
storage.
Attention is drawn to the possibility that some of the elements of this document
may be the subject of patent rights. The issuing authority of this document shall
not be held responsible for identifying any or all such patent rights.
This Standard was proposed by China Food and Drug Administration.
This Standard shall be under the jurisdiction of National Technical Committee
110 on Implants for Surgery and Orthopedic Devices of Standardization
Administration of China (SAC/TC 110).
Drafting organizations of this Standard. Tianjin Medical Device Quality
Supervision and Inspection Center, Beijing Fule Science & Technology
Development Co., Ltd., Naton Intl. Orthopaedic Research Center.
Main drafters of this Standard. Zhang Zhenghui, Zhang Wenhui, Qiu Wanyu,
Guo Zixue, Jiang Yao, Li Renyao.
This Standard replaces YY/T 91141-1999, YY 91071~91073-1999.
The previous versions of YY/T 91141-1999 were released as follows.
- WS 2-302-1983, YY/T 91141-1999.
General technique requirements for osteotome
1 Scope
This Standard specifies the type and basic dimensions, material, requirements,
test methods, and marking of osteotome.
This Standard applies to surgical instruments used in orthopedic chisel.
2 Normative references
The following documents are indispensable for the application of this document.
For the dated references, only the versions with the dates indicated are
applicable to this document. For the undated references, the latest version
(including all the amendments) are applicable to this document.
GB/T 230.1-2004 Metallic Rockwell hardness test - Part 1. Test method
(scales A, B, C, D, E, F, G, H, K, N, T)
GB/T 1220 Stainless steel bars
GB/T 4340.1 Metallic materials - Vickers hardness test - Part 1. Test method
GB/T 10610 Geometrical product specifications (GPS) - Surface texture.
Profile method - Rules and procedures for the assessment of surface texture
YY/T 0149-2006 Medical instruments of stainless steel - Test methods of
corrosion resistance
YY/T 0294.1 Surgical instruments - Metallic materials - Part 1. Stainless steel
YY/T 1052 Marking requirements for surgical instruments
3 Terms and definitions
The following terms and definitions are applicable to this document.
3.1 Osteotome
A chisel tool used to cut bones in orthopedic surgery.
4 Requirements
4.3.1.2.2 Gouge with bent head
When the head diameter is 6 mm or 8 mm, APPLY to the test piece with an
acting force of 14000 N (test material with a hardness of not less than 28 HV1
or higher hardness, such as a flat fuse of 40 mm×15 mm×3.2 mm); the cutting
depth shall be ≥1.9 mm.
When the head diameter is 10 mm or 12 mm, APPLY to the test piece with an
acting force of 14000 N (test material with a hardness of not less than 28 HV1
or higher hardness, such as a flat fuse of 40 mm×15 mm×3.2 mm); the cutting
depth shall be ≥1.7 mm.
4.3.2 Osteotome strength
The cutting edge of osteotome shall have good chiseling performance. The
osteotome is hammered 10 times with a 1180 g drop hammer falling from a
height of 260 mm. After chiseling, there shall be no curved blade or broken
blade.
4.4 Hardness
The hardness of the head of osteotome shall not be less than 35 HRC or 350
HV10. The enterprise shall also specify the maximum hardness.
4.5 Dimensions
It shall comply with the technique requirements of the product.
4.6 Corrosion resistance
It shall not be lower than the requirements of Grade b of boiling water test
method for corrosion resistance of medical instruments of stainless steel in
YY/T 0149-2006.
5 Test methods
5.1 Material
The chemical composition shall be sampled on the final product. The test shall
be carried out in accordance with the method specified in the standard of the
selected material. It shall comply with the provisions of 4.1.
5.2 Surface quality
5.2.1 It shall be observed by eyesight or touched by hand. It shall meet the
requirements of 4.4.1.
...... Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.
|