Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
YY/T 0506.2-2016English135 Add to Cart 0-9 seconds. Auto-delivery. Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment. Part 2: Performance requirements and test methods Obsolete
YY/T 0506.2-2009English279 Add to Cart 3 days Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment. Part 2: Performance requirements and performance levels Obsolete
Standards related to (historical): YY/T 0506.2-2016
PDF Preview

YY/T 0506.2-2016: PDF in English (YYT 0506.2-2016)

YY/T 0506.2-2016 PHARMACEUTICAL INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.040 C 46 Replacing YY/T 0506.2-2009, YY/T 0506.3-2005 Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment - Part 2: Performance requirements and test methods ISSUED ON: JANUARY 26, 2016 IMPLEMENTED ON: JANUARY 01, 2017 Issued by: China Food and Drug Administration Table of Contents Foreword ... 3  Introduction ... 5  1 Scope ... 6  2 Normative references ... 6  3 Terms and definitions ... 7  4 Performance requirements ... 8  Appendix A (Normative) Test method ... 11  Appendix B (Informative) Optional test method ... 14  References ... 16  Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment - Part 2: Performance requirements and test methods 1 Scope This part of YY/T 0506 specifies the performance requirements and test methods of surgical drapes, surgical gowns and clean air suits. 2 Normative references The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this standard. GB/T 4744 Textile fabrics - Determination of resistance to water penetration - Hydrostatic pressure test GB/T 6529 Textiles - Standard atmospheres for conditioning and testing GB/T 7742.1 Textiles. Bursting properties of fabrics - Part 1: Hydraulic method for determination of bursting strength and bursting distension GB/T 24218.3 Textiles - Test methods for nonwovens - Part 3: Determination of tensile strength and elongation (strip method) YY/T 0506.1 Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment - Part 1: General requirements for manufacturers processors and products YY/T 0506.4 Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment - Part 4: Test method for linting in the dry state YY/T 0506.5 Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment - Part 5: Test method for resistance to dry microbial penetration YY/T 0506.6 Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment - Part 6: Test method to determine the resistance to wet bacterial penetration Classification of various characteristics of products used as medical devices as minimum performance requirements during traumatic surgery. 3.3.2 High performance Classification of various characteristics of products used as medical devices as stricter performance requirements during traumatic surgery. Note: Examples of surgical procedures that shall be considered to improve the performance level are those that are excessively exposed to fluids, mechanical stress, or longer surgical procedures. 3.4 Product Surgical gowns, surgical drapes and clean air suits. Note: For surgical kits, each surgical gown or drape is considered a product. 3.5 Sterile field The area covered by the sterile surgical drape for aseptic procedures. Note: The sterile area can be located, such as the instrument table. 4 Performance requirements The product must comply with the YY/T 0506 series of standards. When tested according to this standard, it shall meet the requirements specified in Table 1, Table 2 or Table 3. See Appendix A for detailed information on the corresponding test method and its application. If the medical device is intended to be used in a sterile area, then the surgical drape and instrument drape shall meet the requirements of Table 2. Note 1: YY/T 0506.1 gives manufacturers, processors and products, information to be provided and general requirements for production, processing and testing. Note 2: Performance requirements are as specified in accordance with product area and performance level. However, the performance requirements of some features will apply to all performance levels of medical devices and product areas of medical devices. Appendix A (Normative) Test method A.1 General Unless otherwise specified, the atmosphere for pre-conditioning, conditioning and testing shall be carried out in accordance with GB/T 6529. Before the test, the sample shall be state-conditioned without restrictions. A.2 Cleanliness-microbial evaluation test method It shall follow the test method given in YY/T 0506.7 to evaluate the cleanliness- microbial. A.3 Test method for the evaluation of cleanliness-particulate matter It shall follow the test method given in YY/T 0506.4 to estimate the cleanliness- particulate matter. Note: YY/T 0506.4 allows the test to be carried out in a laminar flow hood. If the instruments required for the test are placed in the hood, it is necessary to confirm the occurrence of laminar flow. In order to estimate the cleanliness-particulate matter, the following changes apply to this document. a) It shall calculate the particle count in the range of 3 μm ~ 25 μm. Note: Particles in this specification range are considered to carry microbial. b) Add the particulate matter counts obtained from the first three time points 30s, 60s and 90s according to the following formula to calculate the particulate matter (PM): PM = C30 + C60 + C90 The test results shall be reported in terms of the index of particulate matter (IPM), which is usually expressed in logarithmic values for particulate matter: IPM = log10 PM. Note: This test procedure cannot distinguish between particulate matter and lint in this period of time, so these two parts are included. A.4 Test method for evaluation of lint Appendix B (Informative) Optional test method B.1 Test method for evaluation of liquid control If the manufacturer claims that the liquid control of the product depends on its absorption to achieve its purpose, it is recommended to evaluate it according to GB/T 24218.11 and make the following modifications: a) Distilled water or deionized water is used as the test liquid; b) It shall use the overflow percentage (w) to calculate the liquid retention percentage as follows: Percentage of fluid retention = 1 - w The percentage of liquid retention is the amount of liquid absorbed by the material. Note: Other tests to evaluate absorption such as GB/T 24218.6 or GB/T 24218.12. B.2 Test method for evaluation of breathability It is recommended to evaluate the breathability of the product according to the test of GB/T 5453. The applicable test parameters are: a) Test area: 20 cm2; b) Pressure drop: 100 Pa. Note: Breathability is an important aspect of evaluating the comfort of surgical gowns and surgical drapes (see also Appendix A of YY/T 0506.1), which is a contradiction between protective performance. B.3 Laser resistance It may use the test method as specified in the YY/T 0855 series of standards to give the primary ignition level, penetration level, secondary ignition level of the surgical drapes, so that the doctor can take appropriate protective measures. B.4 Drapability It may follow GB/T 23329 to evaluate the drapability of the surgical gowns and ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.