HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (17 May 2025)

PDF YS/T 1028.4-2015 English


Search result: YS/T 1028.4-2015
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
YS/T 1028.4-2015English115 Add to Cart 0-9 seconds. Auto-delivery. Methods for chemical analysis of lithium iron phosphate. Part 4: Determination of carbon content. High frequency combustion with infrared absorption method Valid

PDF Preview: YS/T 1028.4-2015                   
      

YS/T 1028.4-2015: PDF in English (YST 1028.4-2015)

YS/T 1028.4-2015 YS NONFERROUS INDUSTRY STANDARD OF THE PEOPLE'S REPUBLIC OF CHINA ICS 77.120.99 H 71 Methods for chemical analysis of lithium iron phosphate - Part 4: Determination of carbon content - High frequency combustion with infrared absorption method ISSUED ON: APRIL 30, 2015 IMPLEMENTED ON: OCTOBER 1, 2015 Issued by: Ministry of Industry and Information Technology of PRC Table of Contents Foreword ... 3 1 Scope ... 4 2 Method summary ... 4 3 Reagents and materials ... 4 4 Instruments ... 5 5 Samples ... 5 6 Analysis steps ... 5 7 Precision... 6 8 Test report ... 7 Methods for chemical analysis of lithium iron phosphate - Part 4: Determination of carbon content - High frequency combustion with infrared absorption method 1 Scope This part of YS/T 1028 specifies the method for determining the carbon content in lithium iron phosphate. This part applies to the determination of carbon content in lithium iron phosphate. Measuring range: 0.5%~5.0%. 2 Method summary The sample and flux are put into a porcelain crucible and heated with a high-frequency induction furnace in the oxygen flow. The carbon is burned to generate carbon dioxide, which is carried by the oxygen to the infrared absorption cell. The change of carbon dioxide concentration on infrared absorption energy follows Beer's law. The analysis results of carbon content are directly displayed on the display as a percentage. 3 Reagents and materials 3.1 Oxygen: The purity is not less than 99.5%. 3.2 Desiccant: Anhydrous magnesium perchlorate with a particle size of 0.7 mm~1.2 mm. 3.3 Purifying agent: Soda asbestos with a particle size of 0.7 mm~1.2 mm. 3.4 Pure iron: The purity is greater than 99.8%, and the carbon content is less than 0.002%. 3.5 Tungsten particles: The carbon content is less than 0.002%. 3.6 Porcelain crucible: Before use, the porcelain crucible shall be placed in a muffle furnace and burned at 1200 °C for no less than 2 hours. After it is taken out and cooled slightly, it is stored in a desiccator. Weigh 0.35 g of pure iron (3.4) and 2.0 g of tungsten particles (3.5) and place them in a porcelain crucible (3.6). Measure them in the same range or channel according to 6.5. Repeat the measurement until the reading is stable. Record the smallest, relatively stable and consistent three readings, calculate the average value, and enter it into the instrument. The instrument will automatically deduct the blank value when measuring the specimen. 6.4 Calibration test Select a certified reference material with a carbon content greater than that of the specimen to be tested to calibrate the instrument. Conduct 3 ~ 5 analyses on the selected channel, linearly adjust the system, and obtain the correction coefficient. Then, use a reference material with content similar to that of the specimen for verification, and the sample can be analyzed only within the allowable variation range. 6.5 Determination 6.5.1 Add 0.35 g of pure iron (3.4) to the porcelain crucible (3.6), place the crucible on the electronic balance, and weigh it. Then, add the specimen (6.1) into the porcelain crucible, weigh it, enter the mass of the specimen, and take it down. Add about 2.0 g of tungsten particles (3.5) to cover the specimen, and move the porcelain crucible to the crucible base. NOTE: The dosage of pure iron and tungsten particles depends on the characteristics of the instrument. The dosage shall ensure that the specimen can be completely burned. 6.5.2 Operate according to the instructions of the instrument. The instrument will automatically perform analysis. After the analysis is completed, the mass fraction of carbon will be recorded. 7 Precision 7.1 Repeatability The measured values of two independent test results obtained under repeatability conditions are within the average value range given below; the absolute difference between the two test results does not exceed the repeatability limit (r), the probability of exceeding the repeatability limit (r) does not exceed 5%, and the repeatability limit (r) is obtained by linear interpolation according to the data in Table 1: ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.

Similar standards: GB/T 4295   GB/T 7160   YS/T 1028.2