HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (5 Oct 2024)

SN/T 1588.3-2013 PDF in English


SN/T 1588.3-2013 (SN/T1588.3-2013, SNT 1588.3-2013, SNT1588.3-2013)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
SN/T 1588.3-2013English150 Add to Cart 0-9 seconds. Auto-delivery. Rules for the inspection of luminaires for import and export. Part 3: Particular requirements of luminaries for swimming pools and similar applications Valid
SN/T 1588.3-2006English279 Add to Cart 3 days Particular requirements for the import and export of lighting for the inspection of Part 3: swimming pools and similar fixtures Obsolete
Standards related to (historical): SN/T 1588.3-2013
PDF Preview

SN/T 1588.3-2013: PDF in English (SNT 1588.3-2013)

SN/T 1588.3-2013 GB ENTRY-EXIT INSPECTION AND QUARANTINE INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA Replacing SN/T 1588.3-2006 Rules for the inspection of luminaires for import and export - Part 3. Particular requirements of luminaries for swimming pools and similar applications ISSUED ON. NOVEMBER 6, 2013 IMPLEMENTED ON. JUNE 1, 2014 Issued by. General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China Table of Contents Foreword ... 3  Introduction ... 5  1 Scope ... 6  2 Normative references ... 6  3 Terms and definitions ... 7  4 General requirements ... 7  5 Inspection... 7  6 Qualified batch determination and validity period ... 13  Rules for the inspection of luminaires for import and export - Part 3. Particular requirements of luminaries for swimming pools and similar applications 1 Scope This Part of SN/T 1588 specifies the requirements, sampling, inspection as well as determination of inspection results of import-export luminaries for swimming pools and similar applications. This Part is applicable to the import and export inspection of stationary luminaires used in or in contact with water, such as swimming pool sinks, fountains, paddling pools and garden pools, of luminaires using tungsten filament lamps and LEDs. This Part is not applicable to the import and export inspection of luminaires that are not in contact with water (e.g., installed behind glass panels that are part of the fixture) or portable luminaires. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 2828.1, Sampling procedures for inspection by attributes - Part 1. Sampling schemes indexed by acceptance quality limit(AQL) for lot-by-lot inspection GB 5013.1, Rubber insulated cables of rated voltages up to and including 450/750 V - Part 1. General requirements GB 7000.1-2007, Luminaires - Part 1. General requirements and tests GB 7000.218-2008, Luminaires - Part 2-18. Particular requirements - Luminaries for swimming pools and similar application GB 17625.1, Electromagnetic compatibility – Limits - Limits for harmonic current emissions (equipment input current ≤16 A per phase) GB 17743, Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment GB/T 20145, Photobiological safety of lamps and lamp systems SN/T 1588.2, Rules for the inspection of luminaires for export and import - Part 2. General requirements 3 Terms and definitions For the purposes of this document, the terms and definitions defined in SN/T 1588.2 as well as the followings apply. 4 General requirements 4.1 Safety requirements The safety requirement for luminaries for swimming pools and similar applications shall comply with the provisions of GB 7000.218-2008 and GB 7000.1-2007. Country (regional) differences shall be considered when applicable. 4.2 Electromagnetic compatibility requirements When applicable, the electromagnetic compatibility requirements for luminaries for swimming pools and similar applications shall comply with the provisions of GB 17743 and GB 17625.1. Country (regional) differences shall be considered when applicable. 4.3 Optical radiation safety requirements When applicable, the optical radiation safety requirements for luminaries for swimming pools and similar applications shall comply with the provisions of GB/T 20145-2006. Country (regional) differences shall be considered when applicable. 4.4 Other requirements When applicable, it shall also meet the energy efficiency and environmental protection requirements of the technical regulations of the country (region) used. 5 Inspection 5.1 Selection of inspection supervision mode The inspection supervision mode for particular requirements for import-export luminaries for swimming pools and similar applications shall be either the sampling inspection mode, the type test mode or the conformity verification mode according to relevant national regulations and specific situation. 5.2 Inspection method The inspection method under different inspection and supervision modes is. - sampling inspection mode. batch-by-batch or random batch sampling inspection; - type test mode. type test + random batch sampling inspection; - conformity verification mode. conformity verification + random batch sampling inspection. 5.3 Type test 5.3.1 Sampling Randomly take representative samples from the stereotyped products according to the quantity specified in the product standard for testing. 5.3.2 Inspection content and requirements 5.3.2.1 Safety testing Test all applicable items according to the requirements of GB 7000.218-2008. When applicable, country (regional) differences shall be considered. 5.3.2.2 Electromagnetic compatibility testing When applicable. Test all applicable items according to the requirements of GB 17743 and GB 17625.1. Country (regional) differences shall be considered. 5.3.2.3 Optical radiation safety testing When applicable. Test all applicable items according to the requirements of GB/T 20145. Country (regional) differences shall be considered. 5.3.2.4 Other testing When applicable, it shall also be tested for energy efficiency and environmental protection in accordance with the technical regulations of the country (region) in use. 5.3.3 Result determination and validity period If all tests are qualified, the type test shall pass, otherwise it shall fail. ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.