HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (13 Apr 2025)

NB/T 20318-2014 PDF English


Search result: NB/T 20318-2014
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
NB/T 20318-2014English370 Add to Cart 0-9 seconds. Auto-delivery. Pressure transmitter important to safety in nuclear power plants Valid


NB/T 20318-2014: PDF in English (NBT 20318-2014)

NB/T 20318-2014 ENERGY INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 27.120.20 F 83 Filing number: 47837-2015 Pressure transmitter important to safety in nuclear power plants ISSUED ON: OCTOBER 15, 2014 IMPLEMENTED ON: MARCH 01, 2015 Issued by: National Energy Administration Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative references ... 4  3 Terms and definitions ... 5  4 Transmitter type and electrical parameters ... 7  5 Transmitter’s function and operating conditions ... 8  6 Technical requirements ... 9  7 Inspection and test ... 17  8 Marking, packaging, transportation and storage ... 24  9 Documentation ... 24  Appendix A (Informative) Environmental conditions of pressure transmitters in the containment of nuclear power plants ... 26  Pressure transmitter important to safety in nuclear power plants 1 Scope This standard specifies the basic requirements for the design, manufacture, qualification, testing and documentation of pressure transmitters important to the safety of nuclear power plants. This standard applies to pressure transmitters important to the safety for continuous monitoring of process variables (pressure, flow, differential pressure, level) in nuclear power plants. 2 Normative references The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this standard. GB 4208-2008 Degrees of protection provided by enclosure (IP code) GB/T 12727-1991 Qualification of electrical items of the safety systems for nuclear power generating stations GB/T 13625-1992 Seismic qualification of electrical equipment of the safety system for nuclear power plants GB/T 17626.2-2006 Electromagnetic compatibility (EMC) - Testing and measurement techniques - Electrostatic discharge immunity test GB/T 17626.3-2006 Electromagnetic compatibility - Testing and measurement techniques - Radiated radio-frequency electromagnetic field immunity test GB/T 17626.4-2008 Electromagnetic compatibility - Testing and measurement techniques - Electrical fast transient/burst immunity test GB/T 18271.2-2000 Process measurement and control devices - General methods and procedures for evaluating performance - Part 2: Tests under reference conditions GB/T 18271.3-2000 Process measurement and control devices - General methods and procedures for evaluating performance - Part 3: Tests for the effects of influence quantities NB/T 20001-2013 Fabrication rules for mechanical components of PWR nuclear island NB/T 20002-2013 (All parts) welding code for mechanical components of PWR nuclear islands NB/T 20019-2010 Ageing, screening, and derating rules of electronic elements and devices in safety class instrument and control equipment of nuclear power plants NB/T 20069-2012 Performance monitoring test of instrumentation channels important to safety in nuclear power plants NB/T 20149-2012 Qualification procedure for pressure transmitter important to safety of nuclear power plants EJ/T 564-2006 Requirements for packaging, transportation, handling, receiving, storing, maintaining nuclear power plant items JJG 882-2004 Pressure transmitter HAF 603 (2007) Management provisions for welding operator qualification of civil nuclear safety equipment 3 Terms and definitions The following terms and definitions apply to this document. 3.1 Error The algebraic difference between the measured value and the true value of the measured variable. Note: When the measured value is greater than the true value, the error is a positive value. The error is usually expressed as a percentage of the corresponding ideal range. [GB/T 18271.1-2000, definition 3.8] 3.2 Accuracy 6 Technical requirements 6.1 General performance requirements 6. 1.1 Basic performance 6.1.1.1 Basic error The basic error of the transmitter shall include the hysteresis and dead band under certain conditions, which shall be at least grade 0.5. The test method is carried out in accordance with the requirements of 7.3.1. Note 1: The basic error is expressed as a percentage of the transmitter range. Note 2: When the transmitter has a field indicator, its error is not included in the transmitter's error. 6.1.1.2 Repeatability error The repeatability error of the transmitter shall not exceed 1/2 of the absolute value of the basic error. The test method is carried out in accordance with the requirements of 7.3.2. 6.1.1.3 Functional accuracy The functional accuracy of the transmitter shall be calculated according to the sum of square roots of the errors produced by various influences. Except for special requirements from users, its value shall not be greater than 2% under normal operating conditions. 6.1.1.4 Response time The response time required by the pressure transmitter shall be determined according to the system function requirements. Except for special requirements from users, it shall not be greater than 1.2s (at 90%). 6.1.2 Electrical performance 6.1.2.1 Insulation resistance The insulation resistance between the output terminal of the transmitter and the housing shall not be less than 100 MΩ. The test method is carried out in accordance with the requirements of 7.3.12. 6.1.2.2 Insulation strength The pressure transmitter shall be subjected to insulation strength test under various operating environment conditions, without breakdown, flashover or 0.25%/6.9 MPa of the range. The test method is carried out according to the requirements of 7.3.9. 6.1.3.7 Impact of one-way overload Enter the maximum working pressure into the negative (or positive) cavity of the differential pressure transmitter. After the pressure is removed, the change in its lower limit value shall be corrected by zero adjustment. Enter the maximum overload pressure for the relative pressure transmitter and the absolute pressure chamber. After the pressure is removed, it will not cause a permanent drift of more than ± 0.5% on the calibration curve. The test method is carried out in accordance with the requirements of 7.3.10. 6.1.3.8 Impact of ambient temperature When the ambient temperature is from 20 °C ± 2 °C to -25 °C ~ 70 °C or any other temperature in the specified temperature range, the impact on accuracy shall meet the requirements of 6.1.1.3 for the functional accuracy through calculation. For remote capillary pressure transmitters, the impact of ambient temperature is determined by the manufacturer. The test method is carried out in accordance with the requirements of 7.3.5. 6.1.3.9 Humidity impact Under the conditions of temperature of 40 °C ± 2 °C and relative humidity of 91% ~ 95%, the insulation resistance of the transmitter shall not be less than 2MΩ; meanwhile its temperature influence and residual change shall meet the requirements of 6.1.3.8. The test method is carried out in accordance with the requirements of Chapter 6 of GB/T 18271.3-2000. 6.1.3.10 Impact of output load When the load resistance changes from the minimum value to the maximum value as specified by the manufacturer, the change of its output signal shall not exceed one half of the basic error. The test method is carried out in accordance with the requirements of 7.3.8. 6.1.3.11 Impact of mechanical vibration Except for the special requirements of the user, under the mechanical vibration of the frequency range of the transmitter of 10 Hz ~ 60 Hz, the peak amplitude of 0.07 mm, the frequency range of 60 Hz ~ 150 Hz, the acceleration of 9.8 m/s2, the change of output signal shall not exceed 1/2 of the basic error. The test is carried out at 50% of the maximum range according to the requirements of Chapter 7 of GB/T 18271.3-2000. environment. For the related requirements of electromagnetic compatibility test, for pressure and differential pressure transmitters, it shall at least carry out electrostatic discharge immunity test, radio frequency electromagnetic field radiation immunity test, electrical fast transient pulse group immunity test; the severity level of the test shall be at least level 2. If the user has special requirements, it is defined in the technical specifications. The test method is carried out in accordance with the requirements of 7.3.17. 6.1.7 Ripple If the user has no special requirements, the ripple value in the output signal of the transmitter shall not exceed 0.1% of the range. The test method is carried out in accordance with the requirements of 7.3.4. 6.1.8 Impact of accelerated working life test After the transmitter has input alternating signals for 105 cycles, the change of lower limit value and range shall not exceed the absolute value of the basic error limit of the maximum range. The test method is carried out in accordance with the requirements of Chapter 23 of GB/T 18271.3-2000. 6.1.9 Shift The functional accuracy of the transmitter after the range shift shall meet the functional accuracy requirements in 6.1.1.3. The test method is carried out in accordance with the requirements of 7.3.14. 6.2 Nuclear safety-related performance requirements 6.2.1 Aging impact The transmitter shall be subjected to aging test according to NB/T 20149-2012. After the test, it shall be adjusted to meet the basic error requirements. 6.2.2 Irradiation impact For the transmitters important to safety installed in a containment, they shall be able to withstand a radiation test with a cumulative dose of 6 x 105 Gy in an accident environment. Except for the special requirements of the user, the maximum allowable error during and after the test shall not exceed ± 8% of the maximum range. The test method is carried out according to the requirements of NB/T 20149- 2012. the reactor coolant. If the user has other special requirements, it shall be clarified in the technical specifications. 6.3.1.4 Material procurement and inspection When outsourcing basic materials (such as sheet metal, Bourdon pipe), manufacturers need to prepare technical specifications for procurement, use materials standards that meet the contract requirements or are agreed upon, meanwhile meet the following requirements: In addition to the standard and necessary inspections, the following tests are required: a) Complete melting chemical analysis and composition analysis (C, Cr, Ni, Mo); b) Mechanical test: For the parts that need to bear the load, it shall carry out the yield strength and Charpy V-notch impact strength test at 20 °C (when the size of the base material is allowed for testing) c) It shall perform the ultrasonic inspection of rods with a diameter greater than 50 mm, perform the liquid penetration inspection of rods with a diameter less than 50 mm but greater than 25 mm. For acceptance criteria, see NB/T 20001-2013. 6.3.2 Welding For the welding material procurement, welding process qualification and welding of the transmitter, see NB/T 20002.1 ~ 7-2013. Welders and welding operators shall be qualified and assessed in accordance with HAF 603 (2007). 6.3.3 Installation and protection 6.3.3.1 Impact of installation The transmitter's detection diaphragm is set to the normal working position when it is perpendicular to the horizontal plane; it is tilted by 10° from front to back and left to right at normal working position. After adjusting the zero point, the lower limit value and upper limit value shall comply with the basic error requirements. The test method is carried out in accordance with the requirements of 7.3.11. 6.3.3.2 Seal protection level The dustproof and waterproof protection level of the transmitter’s housing shall at least meet the requirements of IP55 as specified in GB 4208-2008. and range immediately after the test. Long-term drift is the change of range and he the lower limit of the range before and after the test. 7.3.4 Ripple test The ripple test is performed on load resistances of 100 Ω and 500 Ω. When the input value is 10%, 90%, and the midpoint of its range, measure the output ripple content. 7.3.5 Test of impact of ambient temperature The test is carried out in a temperature control box. The test temperature sequence is: starting from 20 °C to the lower limit and upper limit of the selected ambient temperature. Each temperature range is specified by the manufacturer. The tolerance of each temperature range is ± 2 °C; the temperature is maintained for 3 hours, so that the internal temperature of the transmitter is thermally stable. Measure the output signal value at each temperature point, as well as the change of the output signal of the transmitter at 20 °C before and after the test (i.e. residual changes). 7.3.6 Response time test The test of the response time of the transmitter is performed in accordance with 7.1 of NB/T 20069-2012. If the user specifies the test method and parameters of the response time, it shall be performed according to the user's requirements. 7.3.7 Test of power supply change The test is performed at two points of 10% and 90% of the range. When the load resistance is 100Ω, the voltage is directly changed from the minimum voltage value corresponding to the 100 Ω load to 45 V DC or the voltage change range required by the user, measure the change of the output signal. 7.3.8 Output load test The test is performed at the 50% point of the range. When the voltage is 45 V DC, the change of the output signal is measured when the load resistance changes from the minimum to the maximum load. 7.3.9 Test of impact of static pressure Verification of the impact of transmitter’s static pressure shall be performed in accordance with 6.2.3.5 of JJG 882-2004. 7.3.10 Unidirectional overload test For differential pressure transmitters, first enter the specified working pressure into the negative pressure cavity; hold it for 1 minute and then remove the maintenance of the transmitter. The operation specifications of nuclear power plants specify the test cycle. The operation & maintenance personnel shall perform the test and record. 8 Marking, packaging, transportation and storage 8.1 Marking The transmitter shall be marked of the following in a prominent position: a) The model and name of the transmitter; b) The accuracy level, measurement range; c) Manufacturer name and trademark; d) Serial number and exit-factory date; e) License mark and number of the transmitter. 8.2 Packaging, transportation and storage Unless the user has special requirements, the packaging of the transmitter shall comply with the requirements of grade B packaging in 5.2.3 of EJ/T 564-2006. The transport of the transmitter shall comply with the provisions of 6.1 of EJ/T 564-2006. The storage of the transmitter shall comply with the requirements for the storage location of grade B items in 9.1.2 of EJ/T 564-2006. 9 Documentation During the design, manufacture, qualification, acceptance, use of pressure transmitter important to safety, it shall retain the necessary documents and inspection and test reports, including factory tests and type tests: a) The manufacturer shall submit quality documents such as quality assurance documents and detailed quality plans applicable to equipment design and construction in accordance with the quality assurance requirements proposed by the purchaser; b) Documents such as qualification outlines and reports; c) Manufacturing, inspection, installation and commissioning documents such as raw material procurement certification documents, raw material re-inspection records, factory test procedures, equipment operation & maintenance manuals; d) Acceptance documents such as acceptance test reports; Appendix A (Informative) Environmental conditions of pressure transmitters in the containment of nuclear power plants A.1 Environmental conditions during installation and before operation In this case, the performance and structure of the device are not permanently affected: a) Ambient temperature limit value: -25 °C ~ + 40 °C; b) Maximum humidity: 100%; c) Water: Splashing; d) Salt: Salty air; e) Dust: Large amount. A.2 Environmental conditions during operation A.2.1 Normal environmental conditions a) Climatic environment 1) Normal value of ambient temperature: (1) Ring corridor: 15 °C ~ + 40 °C; (2) Other areas: 5 °C ~ +55 °C. 2) Atmospheric pressure: 86 kPa ~ 106 kPa, 3) Heat radiation and heat conduction: (1) In repeated circulating air: 0K; (2) In a small ventilation area: +5K. 4) Maximum humidity: 95%. b) Impurities in the air 1) Salt: None; 2) Water: None; ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.

Similar standards: GB/T 13286   NB/T 20149   NB/T 20634   

PDF Preview: NB/T 20318-2014