JB/T 9018-2011 PDF in English
JB/T 9018-2011 (JB/T9018-2011, JBT 9018-2011, JBT9018-2011)
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Name of Chinese Standard | Status |
JB/T 9018-2011 | English | 105 |
Add to Cart
|
0-9 seconds. Auto-delivery.
|
Automated storage and retrieval system. Design rules
| Valid |
JB/T 9018-1999 | English | 599 |
Add to Cart
|
4 days
|
High-bay warehouses. Design rules
| Obsolete |
Standards related to (historical): JB/T 9018-2011
PDF Preview
JB/T 9018-2011: PDF in English (JBT 9018-2011) JB/T 9018-2011
JB
NATIONAL MECHANICAL INDUSTRY STANDARD
OF THE PEOPLE’S REPUBLIC OF CHINA
ICS 53.080
J 83
Record No.. 34938-2012
Replacing JB/T 9018-1999
Automated Storage and
Retrieval System – Design Rules
ISSUED ON. DECEMBER 20, 2011
IMPLEMENTED ON. APRIL 01, 2012
Issued by. Ministry of Industry and Information Technology of PRC
Table of Contents
Foreword ... 3
1 Scope ... 5
2 Normative References ... 5
3 Terms ... 6
4 Unit-goods ... 10
5 Rack ... 10
5.1 Structure calculation ... 10
5.2 Materials ... 11
5.3 Rack load ... 11
5.4 Dimension code ... 11
6 Storage/Retrieval Machine ... 12
6.1 Rated hoisting capacity ... 12
6.2 Speed ... 12
6.3 Parameter selection for structure calculation ... 12
6.4 Type and technical requirements ... 13
6.5 Electrical equipment ... 13
6.6 Safety protection device... 14
6.7 Running environment requirements of storage/retrieval machine ... 14
7 Warehouse Building ... 14
8 Relevant Dimensions among Building Structure, Rack, and Storage/Retrieval Machine ... 15
9 The Relationship between Cell and Goods ... 16
9.1 Code ... 16
9.2 Size ... 16
10 Enter/Exit Warehouse Capability ... 18
Foreword
This Standard was drafted as per the rules specified in GB/T 1.1-2009.
This Standard replaced JB/T 9018-1999 High-Bay Warehouse – Design Rules;
compared with JB/T 9018-1999, this Standard has the major technical changes as
follows.
--- Modify the standard name from “High-Bay Warehouse – Design Rules” to
“Automated Storage and Retrieval System – Design Rules”;
--- Modify the codes of row-direction and bay-direction in the “Terms” (3.9, 3.11 of
this Edition; 3.8, 3.9 of 1999 Edition), and re-define them;
--- Modify the length and width dimension of unit-goods (4.2 of this Edition; 4.2 of
1999 Edition);
--- Modify the appearance dimension deviation of the unit-goods (4.3 of this Edition;
4.3 of 1999 Edition);
--- Expand the parameter range and increase the specifications for the lifting speed,
operating speed of stacker crane, the telescopic speed of goods fork (Table 5 of
this Edition; Table 5 of 1999 Edition);
--- Modify the requirements for the basic design of the warehouse (7.1 of this Edition;
7.2 of 1999 Edition);
--- Revise the minimum distance between the outermost side on the horizontally-
operating terminal of the storage/retrieval machine; cancel the provisions of
1800mm below parts (8.1 of this Edition; 9.1 of 1999 Edition);
--- Combine the requirements for “safety protection device” into one sub-clause (6.6
of this Edition; 8.1~8.8 of 1999 Edition);
--- Add “6.7 operating environment requirements for storage/retrieval machine”.
This Standard was proposed by China Machinery Industry Federation.
This Standard shall be under the jurisdiction of National Technical Committee for
Standardization of Machinery Industry Logistics Storage Equipment (CMIF/TC 10).
Drafting organizations of this Standard. Beijing Materials Handling Research Institute.
Chief drafting staffs of this Standard. Xu Qingcai, Chen Dixin, Zhang Chunpeng.
The historical edition replaced by this Standard is as follows.
Automated Storage and
Retrieval System – Design Rules
1 Scope
This Standard specifies the basic design requirements for the automated storage and
retrieval system (hereinafter referred to as storage and retrieval system) unit-goods,
rack, aisle stacking crane (hereinafter referred to as storage/retrieval machine),
warehouse building, cell and ability into and out of the warehouse.
This Standard is applicable to the automated storage and retrieval system with the
ability of storing (taking) unit-goods, consisted of steel structure rack, storage/retrieval
machine and handling equipment.
2 Normative References
The following documents are essential to the application of this document. For the
dated documents, only the versions with the dates indicated are applicable to this
document; for the undated documents, only the latest version (including all the
amendments) are applicable to this document.
GB/T 700-2006 Carbon Structural Steels
GB/T 783 Lifting Appliance – Range of Maximum Capacities
GB/T 3811-2008 Design Rules for Cranes
GB/T 4205 Basic and Safety Principles for Man-Machine Interface (MMI), Marking
and Identification – Actuating Principles
GB 50009 Load Code for the Design of Building Structure
GB 50016 Code of Design on Building Fire Protection and Prevention
GB 50017 Code for Design of Steel Structures
GB 50018 Technical Code of Cold-Formed Thin-Wall Steel Structure
JB/T 2960 Aisle Stacking Crane – Types and Basic Parameters
JB/T 7016 Storage/Retrieval Machine – Technical Specifications
JB/T 10823 Automated Storage and Retrieval System – Vocabulary
storage/retrieval machine [see Figure 1 b), c) and Figure 2 b), c)].
3.10 Y-direction (level-direction)
In the warehouse elevation, the direction paralleling to the lifting direction of the
storage/retrieval machine [see Figure 1 a), c) and Figure 2 a), c)].
3.11 Z-direction (row-direction)
In the warehouse plane, the direction perpendicular to the running direction of the
storage/retrieval machine [see Figure 1 a), b) and Figure 2 a), b)].
3.12 Bay
The unit of the number of locations in the X-direction [see Figure 1 b), c) and Figure 2
b), c)].
3.13 Level
The unit of the number of locations in the Y-direction [see Figure 1 a), c) and Figure 2
a), c)].
3.14 Row
The unit of the number of locations in the Z-direction [see Figure 1 a), b) and Figure 2
a), b)].
3.15 Operation cycle
The operation cycle indicates the whole process that storage/retrieval machine finishes
once goods storing and taking from the original position, then returns to the original
position. Single operation cycle indicates the whole process that the storage/retrieval
machine finishes the single storing (or taking) goods from the original position. The
compound operation cycle indicates the whole process that the storage/retrieval
machine finishes the goods storing and taking from the original position then return to
the original position.
3.16 Operation cycle time
The time required by the storage/retrieval machine for one operation cycle (in the
warehouse with lane-switching device, it shall also contain the time for the land-
switching of the storage/retrieval machine).
3.17 Original position
The position of the storage/retrieval machine before entering or exiting the warehouse.
6.5.2.3 The operating panel must be equipped with the button that can cut off and
control the main power under the emergency situations. The button shall adopt the red
mushroom shape, and installed in the right front of the operator.
6.6 Safety protection device
The safety protection device of the storage/retrieval machine shall conform to the
provisions of JB/T 11269.
6.7 Running environment requirements of storage/retrieval machine
6.7.1 The periphery of the storage/retrieval machine and the periphery of the relevant
entry/exit warehouse conveyor shall be set 1.8m-high fence, the fence can’t be opened
without permission.
6.7.2 When the storage/retrieval machine is operating, the protection device must be
set to prevent the working personnel to cross the lane; and set the warning sign for no
crossing the lane.
6.7.3 The operation terminal of the storage/retrieval machine shall be set the safety
channel for escaping.
7 Warehouse Building
7.1 The basic design of warehouse shall take into account of the geological
conditions, working load and other factors; strictly control the non-uniform settlement
and deformation of the track basic bearing panel (or bearing beam) of storage/retrieval
machine and rack. Under the maximum working load, the local deformation and slope
tan a of the basic bearing panel (or bearing beam) shall be no greater than ...
...... Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.
|