GB/T 5777-2019 PDF in English
GB/T 5777-2019 (GB/T5777-2019, GBT 5777-2019, GBT5777-2019)
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Name of Chinese Standard | Status |
GB/T 5777-2019 | English | 185 |
Add to Cart
|
0-9 seconds. Auto-delivery.
|
[Including 2021XG1] Automated full peripheral ultrasonic testing of seamless and welded (except submerged arc-welded) steel tubes for the detection of longitudinal and/or transverse imperfections
| Valid |
GB/T 5777-2008 | English | 85 |
Add to Cart
|
0-9 seconds. Auto-delivery.
|
Seamless steel pipe and tubing methods for ultrasonic testing
| Obsolete |
GB/T 5777-1996 | English | 399 |
Add to Cart
|
3 days
|
Seamless steel pipe and tubing--Methods for ultrasonic testing
| Obsolete |
GB 5777-1986 | English | 199 |
Add to Cart
|
2 days
|
Methods for ultrasonic testing of seamless steel pipe and tubing
| Obsolete |
Standards related to (historical): GB/T 5777-2019
Preview PDF (Powered by Google. Reload if blank, scroll for next page)
GB/T 5777-2019: PDF in English (GBT 5777-2019) GB/T 5777-2019
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 77.040.20
H 26
Replacing GB/T 5777-2008
Automated Full Peripheral Ultrasonic Testing
of Seamless and Welded (except Submerged Arc-
Welded) Steel Tubes for the Detection of Longitudinal
and/or Transverse Imperfections
(ISO 10893-10:2011, Non-Destructive Testing of Steel Tubes – Part 10:
Automated Full Peripheral Ultrasonic Testing of Seamless and Welded
(except Submerged Arc-Welded) Steel Tubes for the Detection of Longitudinal
and/or Transverse Imperfections, MOD)
ISSUED ON: JUNE 04, 2019
IMPLEMENTED ON: MAY 01, 2020
Issued by: State Administration for Market Regulation;
Standardization Administration of PRC.
Table of Contents
Foreword ... 3
1 Scope ... 5
2 Normative References ... 5
3 Terms and Definitions ... 6
4 General Requirements ... 7
5 Test Methods ... 7
6 Reference Tube ... 8
7 Equipment Calibration and Re-Inspection ... 12
8 Acceptance ... 13
9 Test Report ... 14
Appendix A (Normative) Test of Longitudinal Defects on the Steel Tube with
Ratio between Specified Outer Diameter and Average Wall Thickness less than
5 ... 15
Appendix B (Normative) Manual/Semi-Automatic Detection of Untested Tube
Ends and Suspicious Areas ... 17
Appendix C (Informative) Technical Differences and Causes between this
Standard and ISO 10893-10:2011 ... 19
Foreword
This Standard was drafted as per the rules specified in GB/T 1.1-2009.
This Standard replaced GB/T 5777-2008 Seamless Steel Pipe and Testing Methods
for Ultrasonic Testing. Compared with GB/T 5777-2008, this Standard has the major
technical changes as follows:
--- Modify the standard name;
--- Modify the applicable scope; delete the electromagnetic sound detection method;
and add Lamb wave and phased array technical detection methods (see Clause
1 of this Edition; Clause 1 of 2008 Edition);
--- Add terms and definitions, and general requirements (see Clauses 3 and 4 of
this Edition);
--- Modify the contents of the detection method; and add Lamb wave detection
method (see Clause 5 of this Edition; Clause 4 of 2008 Edition);
--- Delete the contents of flaw detector (see 6.1 of 2008 Edition);
--- Modify the contents of the probe size (see 5.4 and 5.5 of this Edition; and 6.2 of
2008 Edition);
--- Delete the contents of the detection device, transmission device and sorting
devices (see 6.3, 6.4, 6.5 of 2008 Edition);
--- Modify the schematic diagram of the comparison sample tube (see Figures 1 and
2 of this Edition; Figures 1 and 2 and 2008 Edition);
--- Modify the requirements for the position of the groove (see 6.1.4 of this Edition;
and 5.4.2 of 2008 Edition);
--- Modify the acceptance level and identification (see Table 1 of this Edition; Table
1 of 2008 Edition);
--- Modify the requirements for the minimum depth of the groove (see Table 2 of this
Edition; Table 1 of 2008 Edition);
--- Modify the requirements for the width and length of the groove (see 6.3.1, 6.3.3
of this Edition; Table 1 of 2008 Edition);
--- Modify the requirements for the allowable deviation of the groove depth (see
6.3.2.4 of this Edition; Table 1 of 2008 Edition);
--- Modify the requirements for the calibration and re-inspection of the equipment
(see Clause 7 of this Edition; Clause 8 of 2008 Edition);
--- Delete the informative Appendixes A, B, E, and normative Appendix D from 2008
Edition;
--- Change the normative Appendix C of 2008 Edition into normative Appendix A of
this Standard (see Appendix A of this Edition; Appendix C of 2008 Edition).
--- Add normative Appendix B “Manual/ Semi-Automatic Detection of Untested Pipe
Ends and Suspicious Areas” (see Appendix B of this Edition).
Tis Standard uses the redrafting method to modify and adopt ISO 10893-10:2011 Non-
Destructive Testing of Steel Tubes – Part 10: Automated Full Peripheral Ultrasonic
Testing of Seamless and Welded (except Submerged Arc-Welded) Steel Tubes for the
Detection of Longitudinal and/or Transverse Imperfections.
This Standard conforms to the structure of ISO10893-10: 2011; and there are technical
differences compared to ISO10893-10: 2011.The terms involved in these differences
have been marked by vertical single lines (︱) on the outer margins of the terms;
Appendix C gives a list of corresponding technical differences and their causes.
This Standard was proposed by China Iron and Steel Industry Association.
This Standard shall be under the jurisdiction of National Technical Committee for
Standardization of Steel (SAC/TC 183).
Drafting organizations of this Standard: Hengyang Valin Steel Tube Co., Ltd.; Hubei
Xinyegang Steel Co., Ltd.; and China Metallurgical Information and Standardization
Institute.
Chief drafting staffs of this Standard: Deng Shirong, Tian Yan, Du Daojing, Dong Li,
Zhao Bin, and Hu Caiwang.
The historical editions replaced by this Standard are as follows:
--- GB/T 5777-1996, GB/T 5777-2008.
Automated Full Peripheral Ultrasonic Testing
of Seamless and Welded (except Submerged Arc-
Welded) Steel Tubes for the Detection of Longitudinal
and/or Transverse Imperfections
1 Scope
This Standard specifies the requirements for automated full peripheral ultrasonic
transverse wave (generated by conventional or phased array technology) testing of
seamless and welded (except submerged arc-welded) steel tubes for the detection of
longitudinal and/or transverse imperfections.
Unless the purchaser specifically requires in the contract, the method used is generally
the detection of longitudinal imperfections.
When performing longitudinal imperfection detection, manufacturers can also decide
to use Lamb waves for detection.
For seamless pipes, the supplier and the purchaser can negotiate; the detection
principle of this Standard can be used to detect imperfections in other directions.
This Standard applies to ultrasonic testing of steel pipes with an outer diameter of no
less than 6mm, and a ratio of outer diameter to wall thickness of no less than 5. For
the detection of longitudinal imperfections of steel pipes with a ratio of outer diameter
to wall thickness less than 5, see Appendix A.
The testing of circular hollow parts can be performed with reference to this Standard,
and the manual ultrasonic testing can be performed with reference to this Standard.
2 Normative References
The following documents are essential to the application of this document. For the
dated documents, only the versions with the dates indicated are applicable to this
document; for the undated documents, only the latest version (including all the
amendments) are applicable to this document.
GB/T 9445 Non-Destructive Testing - Qualification and Certification of NDT
Personnel (GB/T 9445-2015, ISO 9712:2012, IDT)
GB/T 12604.1 Non-Destructive Testing – Terminology – Terms Used in Ultrasonic
Testing (GB/T 12604.1-2005, ISO 5577:2000, IDT)
ISO 11484 Steel Products – Employer’s Qualification System for Non-Destructive
Testing (NDT) Personnel
3 Terms and Definitions
For the purpose of this document, the terms and definitions given in GB/T 12604.1 and
ISO 11484 and the following apply.
3.1 Reference standard imperfection
It is used to check the artificial imperfections of non-destructive testing equipment
(such as drilling holes, grooves, and pits).
3.2 Reference tube
It indicates the steels tube or steel sections contained reference standard
imperfections.
3.3 Reference sample
It indicates the samples (such as pipe sections, plates or strips) that contain reference
standard imperfections.
NOTE: This Standard only uses the term "reference tube", and also includes the term reference
sample.
3.4 Tube
It indicates the products with hollow long strip for the cross-section and any shapes on
the opening of both ends.
3.5 Seamless tube
Steel tube that perforate the solid product into a hollow tube; then obtain the final size
through the hot-processing and cold-processing.
3.6 Welded tube
Steel tube coiled by the flat materials into a hollow cylinder and welded the adjacent
edges; then the final size can be obtained through further hot-processing and cold-
processing after welding.