HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (30 Nov 2024)

GB/T 41105.2-2021 PDF in English


GB/T 41105.2-2021 (GB/T41105.2-2021, GBT 41105.2-2021, GBT41105.2-2021)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 41105.2-2021English170 Add to Cart 0-9 seconds. Auto-delivery. Non-destructive testing -- Measurement and evaluation of the X-ray tube voltage -- Part 2: Constancy check by the thick filter method Valid
Standards related to (historical): GB/T 41105.2-2021
PDF Preview

GB/T 41105.2-2021: PDF in English (GBT 41105.2-2021)

GB/T 41105.2-2021 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 19.100 CCS J 04 GB/T 41105.2-2021 / ISO 16526-2:2011 Non-destructive testing - Measurement and evaluation of the X-ray tube voltage - Part 2: Constancy check by the thick filter method 性核查 (ISO 16526-2:2011, IDT) ISSUED ON: DECEMBER 31, 2021 IMPLEMENTED ON: JULY 01, 2022 Issued by: State Administration for Market Regulation; Standardization Administration of PRC. Table of Contents Foreword ... 3  Introduction ... 4  1 Scope ... 5  2 Normative references ... 5  3 Terms and definitions... 5  4 Principles and devices ... 6  5 Measurement ... 8  6 Measurement report ... 9  Appendix A (Informative) Application example ... 11  Non-destructive testing - Measurement and evaluation of the X-ray tube voltage - Part 2: Constancy check by the thick filter method 1 Scope This document specifies the method for checking the constancy of the X-ray system, mainly to check the constancy of the X-ray tube voltage and tube current, AND to check and evaluate the X-ray tube voltage and tube current changes, that may be caused by the aging of the X-ray tube anode target. The method, which is specified in this document, is to measure the dose rate, after defining a filter plate of certain thickness, based on the determined X-ray tube, the filter plate and the measuring device and the distance. The method, which is specified in this document, is very sensitive to tube voltage changes, BUT it cannot measure the absolute value of the X-ray tube voltage. Therefore, a reference value needs to be given and confirmed, for example in an acceptance test of an X-ray system. This document is intended for periodic constancy checks of X-ray systems, by testers using the thick plate filter method, which is a relatively convenient technique. This document applies to the constancy check of the X-ray system, after replacement of components, that may affect the voltage of the X-ray tube. This document applies to all types of X-ray systems, such as potentiostatic, half-wave rectified and pulsed, high-voltage generators, which have a tube current greater than 1 mA. 2 Normative references There are no normative references in this document. 3 Terms and definitions There are no terms and definitions, that need to be defined in this document. LV - Leverage factor; D95 - 95% of the test voltage value, in kilovolts (kV); D100 - 100% of the test voltage value, in kilovolts (kV). 5.2 Constancy check At a given voltage, the constancy check of the tube shall be repeated periodically. Constancy checks are performed, using the same collimator, filter plate (thickness and material), calibrated dosimeter, through the arrangement corresponding to Figure 1. If the measured dose value or dose rate value is within the range of the required deviation T (expressed in %), the constancy check of the ray tube voltage is confirmed; the deviation T is determined, through calculation by formula (2). Where: T - Deviation; LV - Leverage factor; D100measured - Measured value at 100% of the given test voltage; D100nomina - Nominal value at 100% of the given test voltage. In the reference measurement, all basic parameters (distances D1 and D2, filter material and thickness, dosimeter or dose rate meter model) shall be recorded; their arrangement shall remain unchanged, during all subsequent measurements. Appendix A gives examples. 6 Measurement report The measurement report shall contain at least the following information: a) The number of this document, that is, GB/T 41105.2-2021; b) Model and serial number of the X-ray system; c) The working conditions of the X-ray system, such as tube voltage (kV), tube current (mA) and selected focus size, preferably nominal tube voltage and maximum tube current; d) Collimator type and size; ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.