GB/T 38038-2019 PDF English
Search result: GB/T 38038-2019_English: PDF (GB/T38038-2019)
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Name of Chinese Standard | Status |
GB/T 38038-2019 | English | 100 |
Add to Cart
|
0-9 seconds. Auto-delivery.
|
Footwear -- Test methods for slide fasteners -- Resistance to repeated opening and closing
| Valid |
BUY with any currencies (Euro, JPY, GBP, KRW etc.): GB/T 38038-2019 Related standards: GB/T 38038-2019
PDF Preview: GB/T 38038-2019
GB/T 38038-2019: PDF in English (GBT 38038-2019) GB/T 38038-2019
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 61.060
Y 78
GB/T 38038-2019 / ISO 10751:2016
Footwear - Test methods for slide fasteners -
Resistance to repeated opening and closing
(ISO 10751:2016, IDT)
ISSUED ON: OCTOBER 18, 2019
IMPLEMENTED ON: MAY 01, 2020
Issued by: State Administration for Market Regulation;
Standardization Administration of the People's Republic of
China.
Table of Contents
Foreword ... 3
1 Scope ... 4
2 Normative references ... 4
3 Terms and definitions ... 4
4 Principle ... 6
5 Test equipment and materials ... 6
6 Test sample ... 7
7 Steps ... 8
8 Test report ... 9
Footwear - Test methods for slide fasteners -
Resistance to repeated opening and closing
1 Scope
This Standard specifies the test method for resistance to repeated opening and
closing of slide fasteners.
This Standard is applicable to various slide fasteners of which the teeth length
is greater than 80 mm.
2 Normative references
The following referenced documents are indispensable for the application of
this document. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any
amendments) applies.
ISO 18454, Footwear - Standard atmospheres for conditioning and testing
of footwear and components for footwear
ISO 19952, Footwear - Vocabulary
3 Terms and definitions
For the purposes of this document, the terms and definitions defined in ISO
19952 as well as the followings apply.
3.1 slide fastener
a connecting piece for fixing two pieces of flexible material; it is composed of
inter-lockable teeth attached to the opposite edges of two tapes and a movable
slider that spans the teeth; when the slider moves in one direction, the teeth
(3.5) on the two tapes (3.2) can be meshed with each other
NOTE: When the slider (3.3) moves in the opposite direction, the teeth can be separated
(see Figure 1).
teeth
4 Principle
Clip the tape at the open end of the test slide fastener to make it parallel. When
the slide fastener is opened and closed repeatedly, the length and width of the
slide fastener are tight. When the slide fastener is damaged or reaches the set
number of opening and closing, stop testing.
5 Test equipment and materials
5.1 A testing machine with one or more workstations: each workstation has the
following devices.
5.1.1 Fixed clamp: the closed end of the test slide fastener can be tightly fixed,
without damaging the teeth.
5.1.2 Movable clamp: can fix the open end of the test slide fastener and two
independent tapes, without damaging the teeth, as shown in Figure 2.
5.1.3 Clamping system: can fix the length of (25±2) mm of the edge of the test
slide fastener:
a) The center point of the fixed length is (82.5±2.0) mm from the movable
clamp (5.1.2);
b) The lateral movement of each clamp is controlled by the stop clamp. The
moving range is (6±1) mm.
5.1.4 The movable clamp (5.1.2), in a 90° direction relative to the fixed clamp
(5.1.1), applies the force specified in Table 1. Record it as F1, as shown in Figure
2.
5.1.5 Each clamp (5.1.3), in a direction that is parallel to the fixed clamp (5.1.1),
applies the force specified in Table 1. Record it as F2.
5.1.6 Device for fixing the test slider.
5.1.7 With a stroke of (63.5±1.5) mm, at a speed of (60±6) times/min, apply
regular reciprocating motion to the device (5.1.6).
5.1.8 Count the number of operations of the device (5.1.6) until the sample is
damaged.
5.2 Distance measuring equipment: the measuring range is 300 mm, to the
device is too thick to hold, then move the line onto the teeth in the middle of the
slide fastener away from the stop device. Move the first line (6.3) until it is
[D]±1mm away from the second line.
6.5 For each slide fastener, marks shall be made on the edges of the tapes at
(82.5±2.0) mm from the line (6.3).
6.6 If the test slide fastener is less than the minimum distance between the
clamps (5.1.3), then for each test slide fastener:
a) Cut the connecting ends of two leather or textile strips. The minimum width
is 25 mm. The exact length of the leather or textile strip shall be
determined by the clamping system of the machine used.
b) Sew the edge of the back of the tape to the connecting end, Make the
longitudinal centerline of the connecting end and the edge of the chain be
90° and be in accordance with the provisions of 6.5. Use double-row
suture to make the suture parallel to the edge of the test slide fastener
teeth. A suture is (7.0±0.5) mm from the teeth. The other suture is (9.0±0.5)
mm from the teeth. Both sutures shall exceed 25 mm at the end of the
connection.
7 Steps
7.1 Fix the closed end of the slide fastener or any additional strip (6.2) in the
clamp (5.1.1). Align the line (6.4) with the edge of the clamp.
7.2 Fix the open end of the slide fastener in the clamp (5.1.2). Align the line (6.3)
with the edge of the clamp.
7.3 Apply the longitudinal force F1 specified in Table 1 to the clamp. Make the
slide fastener under force in the length direction.
7.4 If the connecting end is connected to the edge of each tape as in 6.6, then
clamp the connecting end into each clamp (5.1.3). Otherwise, clamp the edge
of the tape into the clamp (5.1.3) and ensure that the point (6.5) is in the center
of the clamp. The edge of the clamp is parallel to the teeth and at least 5 mm
away from the edge of the teeth.
7.5 For two clamps (5.1.3), in a direction parallel to the edge of the clamp (5.1.1),
apply the force F2 specified in Table 1. Make the slide fastener under force in
the width direction. Ensure that the distance between the back of each clamp
(5.1.3) and the stop clamp [5.1.3b)] is (6±1) mm.
...... Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.
|