HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (29 Sep 2024)

GB/T 37521.1-2019 PDF in English


GB/T 37521.1-2019 (GB/T37521.1-2019, GBT 37521.1-2019, GBT37521.1-2019)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 37521.1-2019English150 Add to Cart 0-9 seconds. Auto-delivery. Security check for anti-explosives at key place -- Part 1: Foundations Valid
Standards related to (historical): GB/T 37521.1-2019
PDF Preview

GB/T 37521.1-2019: PDF in English (GBT 37521.1-2019)

GB/T 37521.1-2019 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 13.200; 13.230 A 90 Security check for anti-explosives at key place - Part 1: Foundations ISSUED ON: JUNE 04, 2019 IMPLEMENTED ON: DECEMBER 01, 2019 Issued by: State Administration for Market Regulation; Standardization Administration of the PRC. Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative references ... 4  3 Terms and definitions ... 5  4 Basic requirements ... 6  5 Scheme of security check for anti-explosives ... 6  6 Agency for security check for anti-explosives ... 7  6.1 General ... 7  6.2 Responsibility setting ... 7  7 Personnel for security check for anti-explosives ... 8  7.1 General ... 8  7.2 On-site duty ... 9  7.3 Training ... 9  8 Equipment and facilities of security check for anti-explosives ... 10  8.1 General ... 10  8.2 Equipment classification ... 10  8.3 Facility setting ... 10  8.4 Other requirements ... 11  9 Equipping requirements ... 11  9.1 Security check for anti-explosives for personnel and articles ... 11  9.2 Security check for anti-explosives for vehicles ... 12  9.3 Security check for anti-explosives for sites ... 13  9.4 Security resources ... 14  Appendix A (Informative) Recommended list for equipment of security check for anti-explosives ... 15  Bibliography ... 17  Security check for anti-explosives at key place - Part 1: Foundations 1 Scope This Part of GB/T 37521 specifies the basic requirements for the implementation of security check for anti-explosives at key place and the requirements such as scheme, agency, personnel, equipment and facilities, and equipping for security check for anti-explosives. This Part applies to the security check for anti-explosives at key place. It may also be used for reference when other places need to be subjected to security check for anti-explosives. 2 Normative references The following documents are indispensable for the application of this document. For the dated references, only the editions with the dates indicated are applicable to this document. For the undated references, the latest edition (including all the amendments) are applicable to this document. GB 8624 Classification for burning behavior of building materials and products GB/T 15408 Technical requirement of power-supply for security & protection system GB/T 33170.5 Safety requirements for large-scale activities - Part 5: Security resources allocation GB/T 37521.2 Security check for anti-explosives at key place - Part 2: Capability assessment GB/T 37521.3 Security check for anti-explosives at key place - Part 3: Procedure GA/T 1155 Terminology for security check and explosive device disposal 4 Basic requirements 4.1 The responsibility main body of the key place shall be responsible for security check for anti-explosives (“security check for anti-explosives”) at this place; it shall, in accordance with the requirements of laws, regulations, and rules, formulate the system and scheme of security check for anti-explosives at key places. 4.2 The responsibility main body of the key place shall set up an agency for security check for anti-explosives or entrust a qualified agency for security check for anti-explosives to carry out security check for anti-explosives. 4.3 The capability of security check for anti-explosives at key place shall be assessed in accordance with GB/T 37521.2. 4.4 The security check for anti-explosives at key place shall be carried out in accordance with GB/T 37521.3. 5 Scheme of security check for anti-explosives The scheme of security check for anti-explosives shall include but is not limited to the following: a) Analysis of the basic situation of key places; b) Division and definition of areas for security check for anti-explosives; c) Level and method of security check for anti-explosives; d) Procedure of security check for anti-explosives; e) Qualification of agency for security check for anti-explosives; f) Information of person in charge of security check for anti-explosives; g) Personnel for security check for anti-explosives; h) Equipment and facility settings for security check for anti-explosives; i) Emergency disposal scheme. a) According to the scheme of security check for anti-explosives, CHECK the site of the key place and the personnel, articles, and vehicles entering the place; b) Maintain the order of security check for anti-explosives; c) Standardize the use of security check equipment for anti-explosives; d) According to the procedure, dispose of unexpected situations; e) Stay connected with other departments and submit information. 6.2.3 Safeguard The agency for security check for anti-explosives shall set up relevant departments to perform the safeguard duties of security check for anti- explosives, mainly including: a) Provide uniform clothing and uniform identity cards for personnel for security check for anti-explosives; b) Provide auxiliary equipment and facilities for security check for anti- explosives; c) Regularly maintain and guarantee the normal operation of on-site security check equipment for anti-explosives; d) GUARANTEE the on-site information transfer such as order transmission, information transmission, and aid decision making; e) Provide emergency supplies. 7 Personnel for security check for anti-explosives 7.1 General The conditions which the personnel for security check for anti-explosives (hereinafter referred to as security inspectors) shall meet include but are not limited to the following: a) 18 years of age or older; b) Good health; c) No record of public security or criminal punishment for acts of violence; 8 Equipment and facilities of security check for anti- explosives 8.1 General The equipment and facilities of security check for anti-explosives shall meet the following requirements: a) Have qualified report/certificate and equipment test report issued by a nationally recognized inspection/certification agency; b) Be subjected to periodic verification or calibration and have verification, calibration identification and records; c) Be subjected to regular maintenance, timely replacement of failed component; have maintenance records. 8.2 Equipment classification Equipment of security check for anti-explosives, according to their use, may be divided into four categories. See Appendix A: a) Check equipment: equipment used for security check for anti-explosives of personnel, articles, vehicles, and sites; see Table A.1; b) Disposal equipment: equipment used for on-site disposal or removal of explosives; see Table A.2; c) Protective equipment: equipment for protecting personnel and articles; see Table A.3; d) Storage and transportation equipment: equipment for the temporary storage and transportation of explosives; see Table A.4. 8.3 Facility setting 8.3.1 Facilities of security check for anti-explosives shall be arranged in the areas for security check for anti-explosives. A warning line shall be drawn on the periphery. 8.3.2 The area for normal security check and related facilities shall be arranged at the entrance of the place. It shall also set up an area for waiting for check. 9.1.1.1 Security inspector The minimum unit for normal security check for anti-explosives for personal and articles shall be equipped with not less than 4 security inspectors, no less than 1 guide, no less than 2 hand probe inspectors, and no less than 1 operator. 9.1.1.2 Equipment of security check for anti-explosives The equipment of the minimum unit for normal security check for anti- explosives for personal and articles shall mainly include but not limited to: a) X-ray security inspection system; b) Walk-through metal detector; c) Hand-held metal detector; d) Bomb suppression blanket/container (bin). 9.1.2 Sampling security check 9.1.2.1 Security inspector The number of security inspectors responsible for further sampling security check of personnel and articles with suspected explosive devices shall be no less than 3. 9.1.2.2 Equipment of security check for anti-explosives The equipment for sampling security check for anti-explosives for personal and articles shall mainly include but not limited to: a) Liquids security check instrument; b) Trace narcotics/explosives detector; c) Portable explosives testing box. 9.2 Security check for anti-explosives for vehicles 9.2.1 Normal security check 9.2.1.1 Security inspector The security check post of minimum unit for normal security check for anti- explosives for vehicles shall be equipped with not less than 3 security inspectors. ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.