HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (30 Nov 2024)

GB/T 24521-2009 (GB/T 24521-2018 Newer Version) PDF English


GB/T 24521-2009 (GB/T24521-2009, GBT 24521-2009, GBT24521-2009)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 24521-2018English85 Add to Cart 0-9 seconds. Auto-delivery. Method for the determination of specific resistance of carbon raw materials and coke Valid
GB/T 24521-2009English180 Add to Cart 0-9 seconds. Auto-delivery. Method for the determination of specific resistance of coke Obsolete
Newer version: GB/T 24521-2018     Standards related to (historical): GB/T 24521-2018
PDF Preview

GB/T 24521-2009: PDF in English (GBT 24521-2009)

GB/T 24521-2009 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 75.160.10 H 32 Method for the determination of specific resistance of coke ISSUED ON: OCTOBER 30, 2009 IMPLEMENTED ON: MAY 01, 2010 Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of the People's Republic of China. Replaced by GB/T 24521-2018 Table of Contents Foreword ... 3 1 Scope ... 4 2 Normative references ... 4 3 Principle ... 4 4 Instruments ... 4 5 Sample preparation ... 8 6 Test procedure ... 8 7 Result calculation ... 10 8 Test report ... 11 Method for the determination of specific resistance of coke 1 Scope This Standard specifies the principle, instruments, samples, test procedure, and result calculation of the determination of specific resistance of coke. This Standard applies to the determination of specific resistance of coke, graphite, roasted crushed and calcined anthracite. 2 Normative references The following documents contain the provisions which, through reference in this Standard, become the provisions of this Standard. For dated references, their subsequent amendments (excluding corrigendum) or revisions do not apply to this Standard. However, the parties who enter into agreement based on this Standard are encouraged to investigate whether the latest versions of these documents are applicable. For undated reference documents, the latest versions apply to this Standard. GB/T 1997 Coke - Sampling and preparation of samples GB/T 8170 Rules of rounding off for numerical values & expression and judgement of limiting values 3 Principle PUT a dry sample of a certain particle size into the sample tank, PASS a certain intensity of current under a certain pressure, MEASURE the voltage drop at the two ends of the sample, and CALCULATE the specific resistance of the sample according to Ohm’s law. 4 Instruments 4.1 Specific resistance tester (see Figure 1). increased so that the line current can reach 300 mA). The detection circuit is shown in Figure 4. 6.2 Measurement of the line voltage drop: PLACE the upper movable column directly on the lower movable column, HANG the weights, TURN the handle clockwise to make the lever level, ADJUST the line current to 300 mA, and RECORD the voltmeter reading V0 (the reading shall be less than 1 mV, otherwise twist the upper movable column or gently sand the contact surface of the upper and lower movable columns with sandpaper to remove the oxide film, so that the line voltage drops below 1 mV). 6.3 Determination of the position of the spiral micrometer barrel: PLACE the standard steel column between the upper and lower movable columns, HANG the weights, TURN the handle clockwise to make the lever level, ADJUST the position of 16.0 of the spiral micrometer barrel to make it align with the pointer, TIGHTEN the jackscrew on the spiral micrometer barrel to make the spiral micrometer barrel fixed; TURN the handle counterclockwise two turns, and then TURN the handle clockwise again to make the lever level, and CHECK whether the spiral micrometer barrel is in the correct position . 6.4 ALIGN the score line on the sample tank with the upper edge of the orientation circle, TIGHTEN the jackscrew, and PLACE it on the lower movable column; PLACE the funnel on the sample tank; MEASURE the sample with a measuring cup, and slowly POUR it into the funnel, making the sample enter the sample tank in about 20 s. 6.5 REMOVE the funnel, TURN the handle so that the pointer points to the position where the 16.0 mm of the spiral micro barrel is after it rotates counterclockwise two turns, carefully PLACE the upper movable column, CONNECT the lever, HANG the weights, slowly ROTATE the handle half a turn clockwise at a uniform speed, UNSCREW the jackscrew on the orientation circle, the weights shall sink slightly, and continue to slowly ROTATE the handle clockwise at a uniform speed until the lever is level. 6.6 ADJUST the line current to 300 mA, RECORD the reading of the voltmeter, READ and RECORD the height of the sample from the position pointed by the pointer of the spiral micrometer barrel. ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.