GB/T 20975.2-2018 PDF English
Search result: GB/T 20975.2-2018 English: PDF (GB/T20975.2-2018)
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Name of Chinese Standard | Status |
GB/T 20975.2-2018 | English | 150 |
Add to Cart
|
0-9 seconds. Auto-delivery.
|
Methods for chemical analysis of aluminium and aluminium alloys -- Part 2: Determination of arsenic content
| Valid |
GB/T 20975.2-2007 | English | 239 |
Add to Cart
|
3 days
|
Chemical analysis methods of aluminium and aluminium alloys -- Part 2: Determination of arsenic content -- Molybdenum blue spectrophotometric method
| Obsolete |
BUY with any currencies (Euro, JPY, GBP, KRW etc.): GB/T 20975.2-2018 Related standards: GB/T 20975.2-2018
PDF Preview: GB/T 20975.2-2018
GB/T 20975.2-2018: PDF in English (GBT 20975.2-2018) GB/T 20975.2-2018
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 77.120.10
H 12
Replacing GB/T 20975.2-2007
Methods for chemical analysis of
aluminium and aluminium alloys –
Part 2. Determination of arsenic content
ISSUED ON. MAY 14, 2018
IMPLEMENTED ON. FEBRUARY 1, 2019
Issued by. State Administration for Market Regulation;
Standardization Administration of the PRC.
Table of Contents
Foreword ... 3
1 Scope ... 6
2 Method 1. Molybdenum blue spectrophotometric method ... 6
3 Method 2. Hydride generation-atomic fluorescence spectrometry ... 10
4 Quality assurance and control ... 14
5 Test report ... 14
Foreword
GB/T 20975 “Methods for chemical analysis of aluminium and aluminium alloys”
is divided into 31 parts.
- Part 1. Determination of mercury content;
- Part 2. Determination of arsenic content;
- Part 3. Determination of copper content;
- Part 4. Determination of iron content - Orthopenanthroline photometric
method;
- Part 5. Determination of silicon content;
- Part 6. Determination of cadmium content - Flame atomic absorption
spectrometric method;
- Part 7. Determination of manganese content - Potassium periodate
spectrophotometric method;
- Part 8. Determination of zinc content;
- Part 9. Determination of lithium content - Flame atomic absorption
spectrometric method;
- Part 10. Determination of tin content;
- Part 11. Determination of lead content;
- Part 12. Determination of titanium content;
- Part 13. Determination of vanadium content - N-benzoyl-
Nphenylhydroxylamine spectrophotometric method;
- Part 14. Determination of nickel content;
- Part 15. Determination of boron content;
- Part 16. Determination of magnesium content;
- Part 17. Determination of strontium content - Flame atomic absorption
spectrometric method;
- Part 18. Determination of chromium content;
Methods for chemical analysis of
aluminium and aluminium alloys -
Part 2. Determination of arsenic content
1 Scope
This Part of GB/T 20975 specifies the method for determination of arsenic
content in aluminium and aluminium alloys.
This Part applies to the determination of arsenic content in aluminium and
aluminium alloys. All coexisting elements in aluminium and aluminium alloys do
not interfere with the determination of arsenic. The measurement range of
Method 1 is. >0.0005%~0.020%. The measurement range of Method 2 is.
0.000002%~0.0005%.
2 Method 1. Molybdenum blue spectrophotometric
method
2.1 Method principle
The test portion is dissolved with a mixed acid of sulfuric acid, hydrochloric acid,
and nitric acid. The iodide of trivalent arsenic is extracted from the hydrochloric
acid solution with carbon tetrachloride, then transferred to the aqueous phase.
The trivalent arsenic is oxidized to pentavalent arsenic with iodine, to form a
colored complex with ammonium molybdate. At a wavelength of 850 nm of a
spectrophotometer, the absorbance of the complex is measured, to calculate
the mass fraction of arsenic.
2.2 Reagents and materials
Unless otherwise stated, in the analysis, only identified guaranteed reagents
and Grade 1 water are used.
2.2.1 Hydrochloric acid (ρ=1.19 g/mL).
2.2.2 Hydrochloric acid (1+1).
2.2.3 Sulfuric acid (1+1).
dilute to volume, and MIX well. PLACE at 20 °C~30 °C for 40 min.
2.5.4.4 Part of the test solution (2.5.4.3) and the blank test solution (2.5.3) are
transferred into a 5 cm absorption cell. With water as a reference, at a
wavelength of 850 nm of the spectrophotometer, the absorbance is measured.
The absorbance of the blank test solution (2.5.3) is subtracted from the
absorbance of the test solution (2.5.4.3), and the corresponding amount of
arsenic is found from the working curve.
2.5.5 Drawing of working curve
2.5.5.1 PIPETTE 0 mL, 1.00 mL, 2.00 mL, 3.00 mL, 4.00 mL, 5.00 mL, 10.00
mL of arsenic standard solution (2.2.13) into 50 mL volumetric flasks; and
operate as specified in 2.5.4.3.
2.5.5.2 MOVE some of the series of standard solutions (2.5.5.1) into the 5 cm
absorption cell. With water as a reference, at a wavelength of 850 nm of the
spectrophotometer, the absorbance is measured. The arsenic content is taken
as the abscissa; the absorbance, obtained by subtracting the absorbance of the
“zero” concentration solution in the series of standard solutions from the
absorbance of the standard solution, is taken as the ordinate; and the working
curve is drawn.
2.6 Calculation of analytical results
The mass fraction w(As) of arsenic is calculated according to formula (1).
Where.
m1 - The arsenic content found from the working curve, in micrograms (μg);
m0 - The mass of the test portion, in grams (g).
The calculation result retains 2 significant figures.
2.7 Precision
2.7.1 Repeatability
The absolute difference between the two independent determination results
obtained under repeated conditions, within the average range given below,
does not exceed the repeatability limit (r). The situations where the repeatability
limit (r) is exceeded do not exceed 5%. The repeatability limit (r), according to
3.2.5 Mixed acid. Hydrochloric acid (3.2.3) and nitric acid (3.2.4) are mixed in
an equal volume ratio.
3.2.6 Hydrochloric acid (5+95).
3.2.7 Potassium borohydride solution (10 g/L). WEIGH 2.5 g of potassium
borohydride in a beaker; USE sodium hydroxide solution (5 g/L) to dilute to 250
mL and SHAKE well. Prepared when used.
3.2.8 Thiourea-ascorbic acid solution (100 g/L). WEIGH 25 g of thiourea and 25
g of ascorbic acid into a 300 mL beaker; USE water to dissolve and dilute to
250 mL, SHAKE well; and TRANSFER to a brown bottle. Prepared when used.
3.2.9 Standard stock solution of arsenic (1.0 mg/mL). WEIGH 1.320 g of arsenic
trioxide dissolved in 5 mL of sodium hydroxide solution (200 g/L); USE
hydrochloric acid (3.2.3) to acidify until the Congo red paper is blue;
TRANSFER the solution to a 1000 mL volumetric flask; USE water to dilute to
volume, and MIX well. 1 mL of this solution contains 1.0 mg of arsenic.
3.2.10 Arsenic standard solution A (10 μg/mL). PIPETTE 1.00 mL of standard
stock solution of arsenic (3.2.9) into a 100 mL volumetric flask; USE
hydrochloric acid (3.2.6) to dilute to volume, and MIX well. 1 mL of this solution
contains 10 μg of arsenic. Prepared when used.
3.2.11 Arsenic standard solution B (0.1 μg/mL). PIPETTE 1.00 mL of arsenic
standard solution A (3.2.10) into a 100 mL volumetric flask; USE hydrochloric
acid (3.2.6) to dilute to volume, and MIX well. 1 mL of this solution contains 0.1
μg of arsenic. Prepared when used.
3.3 Instrument
Atomic fluorescence spectrometer, with arsenic hollow cathode lamp.
3.4 Sample
The sample is processed into chips having a thickness of no more than 1 mm.
3.5 Analytical procedures
3.5.1 Test portion
Sample (3.4) is weighed according to Table 4, accurate to 0.0001 g.
...... Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.
|