HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (5 Jul 2025)

GB/T 19633.2-2024 PDF English

US$350.00 · In stock · Download in 9 seconds
GB/T 19633.2-2024: Packaging for terminally sterilized medical devices - Part 2: Validation requirements for forming, sealing and assembly processes
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid

GB/T 19633.2: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
GB/T 19633.2-2024English350 Add to Cart 0-9 seconds. Auto-delivery Packaging for terminally sterilized medical devices - Part 2: Validation requirements for forming, sealing and assembly processes Valid
GB/T 19633.2-2015English130 Add to Cart 0-9 seconds. Auto-delivery Packaging for terminally sterilized medical devices -- Part 2: Validation requirements for forming, sealing and assembly processes Valid

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: GB/T 19633.2-2024                   PDF Preview: GB/T 19633.2-2015
            


Similar standards

GB/T 19633.1   GB 18282.5   GB/T 19973.2   

GB/T 19633.2-2024: Packaging for terminally sterilized medical devices - Part 2: Validation requirements for forming, sealing and assembly processes


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT19633.2-2024
GB NATIONAL STANDARD OF THE PEOPLE'S REPUBLIC OF CHINA ICS 11.080.30 CCS C 47 GB/T 19633.2-2024 / ISO 11607-2.2019 Replacing GB/T 19633.2-2015 Packaging for terminally sterilized medical devices - Part 2. Validation requirements for forming, sealing and assembly processes (ISO 11607-2.2019, IDT) Issued on: MAY 28, 2024 Implemented on: DECEMBER 1, 2025 Issued by. State Administration for Market Regulation; Standardization Administration of PRC.

Table of Contents

Foreword... 3 Introduction... 5 1 Scope... 7 2 Normative references... 7 3 Terms and definitions... 7 4 General requirements... 14 5 Validation of packaging processes... 15 6 Assembly... 20 7 Use of reusable sterile barrier systems... 21 8 Sterile fluid-path packaging... 21 Appendix A (informative) Process development... 22 Appendix B (normative) Risk management... 24 References... 29

Foreword

This document was drafted in accordance with the provisions of GB/T 1.1-2020 Directives for standardization - Part 1.Rules for the structure and drafting of standardizing documents. This document is Part 2 of GB/T 19633 Packaging for terminally sterilized medical devices. GB/T 19633 has been published in the following parts. -- Part 1.Requirements for materials, sterile barrier systems and packaging systems; -- Part 2.Validation requirements for forming, sealing and assembly processes. This document replaces GB/T 19633.2-2015 Packaging for terminally sterilized medical devices - Part 2.Validation requirements for forming, sealing and assembly processes. Compared with GB/T 19633.2-2015, in addition to structural adjustments and editorial changes, the main technical changes are as follows. -- The description of the scope has been changed (see Chapter 1; see Chapter 1 of the 2015 edition); -- The terms "aseptic presentation", "closure", "control", "medical device", "microbial barrier", "monitoring", "process parameter", "process specification", "process variable", "seal", "seal strength", "sterile", "terminally sterilized", "hazard", "process" and "risk" and their definitions have been added (see 3.1, 3.2, 3.3, 3.7, 3.8, 3.9, 3.14, 3.15, 3.16, 3.22, 3.23, 3.24, 3.27, 3.29, 3.30 and 3.31); -- The term "process development" and its definition have been deleted (see 3.8 of the 2015 edition); -- The risk management requirements have been added (see 4.2 and Appendix B); -- The sampling requirements for materials and sterile barrier systems have been added (see 4.3); -- The requirements for determining process specifications have been added (see 5.1.3); -- The requirement that the production of preformed sterile barrier systems and sterile barrier systems shall meet the predefined sealing strength has been added in operational qualification (see 5.3.2); -- The requirements for medical devices with sterile fluid circuits marked have been deleted (see 8.2 of the 2015 edition). Packaging for terminally sterilized medical devices - Part 2. Validation requirements for forming, sealing and assembly processes

1 Scope

This document specifies requirements for the development and validation of processes for packaging medical devices that are terminally sterilized. These processes include forming, sealing and assembly of preformed sterile barrier systems, sterile barrier systems and packaging systems. It does not cover all requirements for packaging medical devices that are manufactured aseptically. Additional requirements can be necessary for drug/device combinations.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes the requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 19633.1-2024 Packaging for terminally sterilized medical devices - Part 1. Requirements for materials, sterile barrier systems and packaging systems (ISO 11607-1.2019, IDT)

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminological databases for use in standardization at the following addresses. 3.1 aseptic presentation transfer of sterile contents from its sterile barrier system using conditions and ......