HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (22 Mar 2025)

GB/T 19633.1-2024 PDF English (GB/T 19633.1-2015: Older version)


Search result: GB/T 19633.1-2024 (GB/T 19633.1-2015 Older version)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 19633.1-2024English905 Add to Cart 0-9 seconds. Auto-delivery. Packaging for terminally sterilized medical devices - Part 1: Requirements for materials, sterile barrier systems and packaging systems Valid
GB/T 19633.1-2015English150 Add to Cart 0-9 seconds. Auto-delivery. Packaging for terminally sterilized medical devices -- Part 1: Requirements for materials, sterile barrier systems and packaging systems Valid
GB/T 19633-2005English799 Add to Cart 3 days Packaging for terminally sterilized medical devices Obsolete


PDF Preview: GB/T 19633.1-2024


PDF Preview: GB/T 19633.1-2015


GB/T 19633.1-2024: PDF in English (GBT 19633.1-2024)

GB/T 19633.1-2024 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.080.01 CCS C 47 GB/T 19633.1-2024 / ISO 11607-1:2019 Replacing GB/T 19633.1-2015 Packaging for Terminally Sterilized Medical Devices – Part 1: Requirements for Materials, Sterile Barrier Systems and Packaging Systems (ISO 11607-1:2019, IDT) ISSUED ON: MAY 28, 2024 IMPLEMENTED ON: DECEMBER 1, 2025 Issued by: State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of Contents Foreword ... 3 Introduction ... 6 1 Scope ... 8 2 Normative References ... 8 3 Terms and Definitions ... 9 4 General Requirements ... 16 5 Materials, Preformed Sterile Barrier Systems and Sterile Barrier Systems ... 18 6 Design and Development for Packaging Systems ... 24 7 Usability Evaluation for Aseptic Presentation ... 26 8 Packaging System Performance and Stability ... 27 9 Packaging System Validation and Changes ... 28 10 Inspection Immediately Prior to Aseptic Presentation ... 29 11 Information to be Provided ... 29 Annex A (Informative) Guidance on Medical Packaging ... 31 Annex B (Informative) Standardized Test Methods, Guides and Procedures That Can be Used to Demonstrate Conformity with the Requirements of This Document ... 34 Annex C (Normative) Test Method for Resistance of Impermeable Materials to the Passage of Air ... 52 Annex D (Informative) Environmental Aspects ... 53 Annex E (Informative) Draft Guidance on Ways to Differentiate a Sterile Barrier System from Protective Packaging ... 54 Annex F (Normative) Risk Management ... 59 Annex G (Informative) Risk Management for Medical Device Packaging - Rationale for Requirements ... 64 Bibliography ... 76 Foreword This Document was drafted as per the rules specified in GB/T 1.1-2020 Directives for Standardization – Part 1: Rules for the Structure and Drafting of Standardizing Documents. This Document is Part 1 of GB/T 19633 Packaging for Terminally Sterilized Medical Devices. GB/T 19633 has published the following parts: --- Part 1: Requirements for Materials, Sterile Barrier Systems and Packaging Systems; --- Part 2: Validation Requirements for Forming, Sealing and Assembly Processes. This Document replaced GB/T 19633.1-2015 Packaging for Terminally Sterilized Medical Devices - Part 1: Requirements for Materials, Sterile Barrier Systems and Packaging Systems. Compared with GB/T 19633.1-2015, the major technical changes of this Document are as follows besides the structural adjustments and editorial modifications: --- Change the description of scope (see Clause 1 of this Edition; Clause 1 of the 2015 Edition); --- Add the terms "control", "supervision", "terminally sterilized", "expiration date", "hazard", "intended use", "intended purpose", "process", "reasonably foreseeable misuse", "risk" and their definitions (see 3.5, 3.10, 3.28, 3.29, 3.32, 3.33, 3.34, 3.35 and 3.36 of this Edition); --- Delete the terms "packaging material" and "recycled material" and their definitions (see 3.9 and 3.14 of the 2015 Edition); --- Add the requirements for risk management (see 4.2, Annex F of this Edition); --- Add the sampling requirements for materials and sterile barrier systems (see 4.3 of this Edition); --- Add the requirements for the microbial barrier properties of materials [see 5.1.7h) of this Edition]; --- Add the requirements for confirming compliance with ISO11607-2 and the sub-clause for reversible seals or closures [see 5.1.9 a), f) of this Edition]; --- Add requirements for aseptic access (see 6.1.2 of this Edition); --- Add performance evaluation requirements for selection and confirmation of materials and preformed aseptic barrier systems (see 6.2.2 of this Edition); --- Add labeling requirements on protective packaging of aseptic liquid products (see 6.2.5 of this Edition); --- Add requirements for usability evaluation of aseptic access (see Clause 7 of this Edition); --- Add general requirements for performance and stability of packaging systems (see 8.1 of this Edition); --- Change the test objects of performance tests (see 8.2.2 of this Edition; 6.3.4 of the 2015 Edition); --- Add requirements for forming documents to determine the worst-case principle (see 8.2.3 of this Edition); --- Change the time when real-time aging starts (see 8.3.4 of this Edition; 6.4.4 of the 2015 Edition); --- Add packaging system validation and changes (see Clause 9 of this Edition); --- Add requirements for inspection immediately prior to aseptic presentation (see Clause 10 of this Edition). This Document equivalently adopted ISO 11607-1:2019 Packaging for Terminally Sterilized Medical Devices – Part 1: Requirements for Materials, Sterile Barrier Systems and Packaging Systems. The following minimal editorial changes were made to this Document: --- Incorporate the amendments of ISO11607-1:2019/Amd.1:2023, and the outer margins of the involved clauses are marked with vertical double lines (‖); --- Add NOTE 2 to 3.8; --- Adjust the format of Table B.1, adding a column "Chinese standard number corresponding to the reference standard", and merged "reference standard" and "name" into one column; --- Added NOTE to Annex E; --- Change the numbers of the NOTEs in F.2 and F.7. Please note some contents of this Document may involve patents. The issuing agency of this Document shall not assume the responsibility to identify these patents. This Document was proposed by National Meical Products Administration. This Document shall be under the jurisdiction of National Technical Committee on Disinfection Technology and Equipment of Standardization Administration of China (SAC/TC 200). Drafting organizations of this Document: Guangdong Medical Devices Quality Surveillance and Test Institute; Shanghai MicroPort Medical (Group) Co., Ltd.; DuPont (China) Research & Packaging for Terminally Sterilized Medical Devices – Part 1: Requirements for Materials, Sterile Barrier Systems and Packaging Systems 1 Scope This Document specifies requirements and test methods for materials, preformed sterile barrier systems, sterile barrier systems and packaging systems that are intended to maintain sterility of terminally sterilized medical devices until the point of use. This Document does not cover all requirements for sterile barrier systems and packaging systems for medical devices that are manufactured aseptically. Additional requirements can be necessary for drug/device combinations. This Document does not describe a quality assurance system for control of all stages of manufacture. This Document does not apply to packaging materials and/or systems used to contain a contaminated medical device during transportation of the item to the site of reprocessing or disposal. 2 Normative References The provisions in following documents become the essential provisions of this Document through reference in this Document. For the dated documents, only the versions with the dates indicated are applicable to this Document; for the undated documents, only the latest version (including all the amendments) is applicable to this Document. ISO 5636-5 Paper and board – Determination of air permeance (medium range) – Part 5: Gurley method ISO 11607-2 Packaging for terminally sterilized medical devices – Part 2: Validation requirements for forming, sealing and assembly processes NOTE: GB/T 19633.2-2024 Packaging for terminally sterilized medical devices - Part 2: Validation requirements for forming, sealing and assembly processes (ISO 11607-2:2019, IDT) ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.