HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (1 Dec 2024)

GB/T 1962.2-2001 PDF in English


GB/T 1962.2-2001 (GB/T1962.2-2001, GBT 1962.2-2001, GBT1962.2-2001)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 1962.2-2001English70 Add to Cart 0-9 seconds. Auto-delivery. Conical fittings with a 6% (Luer) taper for syringes, needles and certain other medical equipment -- Part 2: Lock fittings Valid
Standards related to (historical): GB/T 1962.2-2001
PDF Preview

GB/T 1962.2-2001: PDF in English (GBT 1962.2-2001)

GB/T 1962.2-2001 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.040.20 C 31 GB/T 1962.2-2001 / idt ISO 594-2:1998 Conical fittings with a 6 % (Luer) taper for syringes, needles and certain other medical equipment - Part 2: Lock fittings 注射器, 注射针及其他医疗器械 6 %(鲁尔)圆锥接头 ISSUED ON: SEPTEMBER 18, 2001 IMPLEMENTED ON: FEBRUARY 01, 2002 Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the PRC Table of Contents Foreword ... 3  ISO Foreword ... 4  1 Scope ... 5  2 Reference standards ... 5  3 Dimensions ... 6  4 Requirements ... 10  5 Test methods ... 12  Foreword This Standard is identical to ISO 594-2:1998 "Conical fittings with 6 % (Luer) taper for syringes, needles and certain other medical equipment - Part 2: Lock fittings". This Standard was proposed by National Medical Products Administration. This Standard shall be under the jurisdiction of National Technical Committee 95 on Injector for Medical Purpose of Standardization Administration of China. Drafting organization of this Standard: Shanghai Centre for Medical Equipment Quality Supervision and Testing, National Medical Products Administration. Main drafters of this Standard: Fu Guobao, Zhao Jing. Conical fittings with a 6 % (Luer) taper for syringes, needles and certain other medical equipment – Part 2: Lock fittings 1 Scope This Standard specifies dimensions, requirements, test methods for conical lock fittings with a 6 % (Luer) taper for use with hypodermic syringes and needles and with certain other apparatus for medical use, e.g. transfusion equipment. The requirements apply to fittings made of rigid and of semi-rigid materials and include test methods, but exclude provision for more flexible or elastomeric materials. Note 1 It is not practicable to define the characteristics of rigid or semi-rigid materials with precision, but glass and metal may be considered as typical rigid materials. In contrast many plastics materials may be regarded as semi-rigid. 2 The Luer lock fitting was designed for use at pressures of the order of 300 kPa or lower. 2 Reference standards The following standards contain provisions which, through reference in this Standard, constitute provisions of this Standard. At the time of publication of this Standard, the editions shown are valid. All standards will be revised. Parties using this Standard shall explore the possibility of using the latest editions of the following standards. GB/T 1031-1995 Surface roughness - Parameters and their values GB/T 1962.1-2001 Conical fittings with a 6% (Luer) taper for syringes, needles and certain other medical equipment - Part 1: General requirement (idt ISO 594-1:1986) GB 15810-2001 Sterile hypodermic syringes for single use (eqv ISO 7886- 1:1993) ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.