HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (12 Jan 2025)

GB/T 19348.1-2014 PDF English


Search result: GB/T 19348.1-2014_English: PDF (GB/T19348.1-2014)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 19348.1-2014English125 Add to Cart 0-9 seconds. Auto-delivery. Non-destructive testing -- Industrial radiographic film -- Part 1: Classification of film systems for industrial radiography Valid
GB/T 19348.1-2003English239 Add to Cart 3 days Non-destructive testing -- Industrial radiographic films -- Part 1: Classification of film systems for industrial radiography Obsolete
BUY with any currencies (Euro, JPY, GBP, KRW etc.): GB/T 19348.1-2014     Related standards: GB/T 19348.1-2014

PDF Preview: GB/T 19348.1-2014


GB/T 19348.1-2014: PDF in English (GBT 19348.1-2014)

GB/T 19348.1-2014 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 37.040.25; 19.100 J 04 Replacing GB/T 19348.1-2003 Non-destructive Testing – Industrial Radiographic Film – Part 1. Classification of Film Systems for Industrial Radiography (ISO 11699-1. 2008, MOD) ISSUED ON. JUNE 24, 2014 IMPLEMENTED ON. DECEMBER 31, 2014 Issued by. General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of the People's Republic of China. Table of Contents Foreword ... 3  1 Application Scope ... 5  2 Normative References ... 5  3 Terms and Definitions ... 5  4 Sampling and Storage ... 7  5 Test Method ... 8  6 Limiting Values for Classification ... 13  Bibliography ... 15  Foreword GB/T 19348, Non-destructive Testing – Industrial Radiographic Film, is divided into two parts. -- Part 1. Classification of Film Systems for Industrial Radiography -- Part 2. Control of Film Processing by Means of Reference Values This Part is the 1st part of GB/T 19348. This Part was drafted in accordance with the rules given in GB/T 1.1-2009. This Part replaces GB/T 19348.1, Non-destructive Testing – Industrial Radiographic Film - Part 1. Classification of Film Systems for Industrial Radiography. Compared with GB/T 19348.1-2003, the main technical changes of this Part, except editorial changes, are as follows. -- adds normative references (see Article 2); -- modifies part of test methods (see Article 5; Article 4 of Edition 2003); and -- modifies limiting values for classification. This Part was redrafted by modifying and adopting ISO 11699-1.2008, Non-destructive Testing – Industrial Radiographic Film – Part 1. Classification of Film Systems for Industrial Radiography. The main technical differences and their reasons between this Part and ISO 11699- 1.2008 are as follows. -- for normative references, some adjustments with technical differences are made in this Part, in order to suit the technical conditions of China. The details of adjustments are mainly reflected in Article 2 “Normative References”, including.  uses Chinese standard GB/T 19348.2 to replace ISO 11699-2 (Article 1 and 5.2); and  uses Chinese standard GB/T 27025 to replace ISO/IEC 17025 (see 5.5). This Part was proposed by and shall be under the jurisdiction of the National Technical Committee 56 on Non-destructive Testing of Standardization Administration of China (SAC/TC 56). The drafting organizations of this Part. Shanghai Taisi Testing Technology Co., Ltd., Shanghai Electric Nuclear Power Group Co., Ltd., Shanghai Research Institute of Materials, COMAC Shanghai Aircraft Design and Research Institute, Shanghai Key Laboratory for Application and Evaluation of Engineering Materials and Carestream Asia-Pacific Investment Management (Shanghai) Co., Ltd. Non-destructive Testing – Industrial Radiographic Film – Part 1. Classification of Film Systems for Industrial Radiography 1 Application Scope The purpose of this Part of GB/T 19348 is to establish the performance of film systems. This Part is applicable for the classification of film systems in combination with specified lead screens for industrial radiography (non-destructive testing). This Part is intended to ensure that the image quality of radiographs – as far as this is influenced by the film system – is in conformity with the requirements of other standards such as ISO 5579, ISO 17636 and EN 12681. This Part does not apply to the classification of films used with fluorescent intensifying screens. The measurement of film systems in this Part is restricted to a selected radiation quality to simplify the procedure. The properties of films will change with radiation energy, but not the ranking of film system quality. Additional methods for evaluating the photographic process are described in GB/T 19348.2, by which the performance of film systems can be controlled under the conditions given in industry. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 19348.2, Non-destructive Testing – Industrial Radiographic Films – Part 2. Control of Film Processing by Means of Reference Values (GB/T 19348.2-2003, ISO 11699-2.1998, IDT) GB/T 27025, General requirements for the competence of testing and calibration laboratories (GB/T 27028-2008, ISO/IEC 17025.2005, IDT) 3 Terms and Definitions For the purpose of this document, the following terms and definitions apply. layers. The granularity value shall be determined in terms of diffuse density. If the optical density is measured as specular density, it shall be converted into diffuse optical density, using the plot of the curve of diffuse density versus specular density at the mean density value of the granularity film specimen. The diffuse density of each step shall be measured with the calibrated densitometer. Determine this curve using a film having a stepped series of densities, which is prepared using the same type of film, exposure, and processing techniques as used for the granularity film specimen. The specimen film shall be scanned using identical microdensitometer settings. A limited range of densities can typically be measured for a given microdensitometer gain setting. The stepped series of densities shall lie within that range. The calibration shall be made from the diffuse versus specular density plot with at least 5 values between diffuse density 1.5 and 2.8 (including fog and base). The conversion can be performed on basis of a linear regression analysis of the log (diffuse density) versus log (specular density) plot. The determined coefficients shall be used for the conversion of the specular density into diffuse density values. The conversion shall be performed before the numerical determination of the standard deviation, σD, which is a measure of the granularity. σD is calculated as follows. The diffuse optical density of the measured film shall be D = 2.00 ± 0.05 above fog and base. The determined value of σD shall be corrected on the basis of the diffuse mean density D above fog and base of this film. The corrected value of σD (σD,corr) is calculated as follows. As an alternative, three or more samples of the film specimen at different density levels may be measured within the range from 1.80 to 2.20, and the granularity value at a diffuse density of 2.0 above base plus fog shall be taken from a linear regression analysis of the plot of granularity as a function of the square root of diffuse density above fog and base. The scanning length on the radiographic film shall be at least 116 mm. The diameter of a circular measuring aperture of the microdensitometer shall be (100 ± 5) μm. A square aperture of 88.6 μm × 88.6 μm has the same area as a circular one of 100 μm diameter. The measured granularity is equivalent to that of a circular one with 100 μm diameter. the median value σD,med is multiplied by . In the case of 20 observations, the median value σD,med is multiplied by 1.017 9 for statistical correction. NOTE 2 An increased number of data points and groups yields a better (lower) uncertainty of the result. It is important not to modify the group length of 1.9 mm (plus 0.1 mm distance between groups) and the statistical correction if using 1.017 9 as correction value. Subdivision of the scanned data in groups, determination of σD and median procedure have an inherent filter effect which is equivalent to the described high-pass filter of scanned data. Therefore, the high-pass filtering may be omitted if the median procedure is applied. Differences in the determined granularity will be less than ± 1.5 %. At least six measurements shall be made on different samples to estimate the mean value of granularity. The determined granularity mean value shall not exceed an uncertainty of ± 10 % at a confidence level of 95 %. Measurement laboratories, which certify film systems, shall participate in a proficiency test on a periodical basis. A new film, exposed in accordance with this Part of GB/T 19348, shall be used in all participating laboratories and for each periodical test. 5.4 Measurement of ISO speed S The ISO speed S is determined for a diffuse optical density (D − D0 = 2) above fog and base D0. The ISO speed shall be given in accordance with Table 2. 5.5 Other equipment and procedures Measurement equipment other than that described above can be used for classification if that equipment and the corresponding procedures provide the same results ۛ with an uncertainty of less than 5 % and a confidence of 95 % for gradient G2, ۛ with an uncertainty of less than 7 % and a confidence of 95 % for gradient G4, and ۛ with an uncertainty of less than 10 % and a confidence of 95 % for granularity. The requirements of GB/T 27025 shall be met with respect to the test method of 5.1 t... ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.