HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (5 Oct 2024)

GB/T 18443.1-2010 PDF in English


GB/T 18443.1-2010 (GB/T18443.1-2010, GBT 18443.1-2010, GBT18443.1-2010)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 18443.1-2010English70 Add to Cart 0-9 seconds. Auto-delivery. Testing method of performance for vacuum insulation cryogenic equipment -- Part 1: Basic requirements Valid
GB/T 18443.1-2001English199 Add to Cart 2 days Testing method of cryo-insulation pressure vessels -- Volume measurement Obsolete
Standards related to (historical): GB/T 18443.1-2010
PDF Preview

GB/T 18443.1-2010: PDF in English (GBT 18443.1-2010)

GB/T 18443.1-2010 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 23.020 J 74 Testing method of performance for vacuum insulation cryogenic equipment - Part 1.Basic requirements ISSUED ON. SEPTEMBER 26, 2010 IMPLEMENTED ON. FEBRUARY 01, 2011 Issued by. General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the People’s Republic of China. Table of Contents Foreword... 3  1 Scope... 4  2 Normative references... 4  3 Terms and definitions... 5  4 General requirements... 6  Appendix A (Normative) Determination of standard heat-leak rate and static evaporation rate of the actually-stored medium... 9  Appendix B (Informative) Test items and sequence... 11  Appendix C (Informative) Performance test report of vacuum insulated cryogenic equipment... 12  Testing method of performance for vacuum insulation cryogenic equipment - Part 1.Basic requirements 1 Scope This Part of GB/T 18443 specifies the basic requirements for the test environment, test equipment, measured piece and test medium, test items and sequence, data processing, test record and test report of the performance test of vacuum insulated cryogenic equipment. This Part applies to the performance test of vacuum insulated cryogenic equipment other than the storage and transportation of liquid hydrogen medium; it also applies, as a reference, to the implementation of other equipment. 2 Normative references The terms in the following documents become the terms of this Part through the reference of this Part of GB/T 18443.For dated references, all subsequent amendments (not including errata content) or revisions do not apply to this Part. However, parties to agreements that are based on this Part are encouraged to study whether the latest versions of these documents can be used. For undated references, the latest edition applies to this Part. GB/T 18443.2, Testing method of performance for vacuum insulation cryogenic equipment - Part 2.Vacuum degree measurement GB/T 18443.3, Testing method of performance for vacuum insulation cryogenic equipment - Part 3.Leak rate measurement GB/T 18443.4, Testing method of performance for vacuum insulation cryogenic equipment - Part 4.Leak-outgassing rate measurement GB/T 18443.5, Testing method of performance for vacuum insulation cryogenic equipment - Part 5.Static evaporation rate measurement GB/T 18443.6, Testing method of performance for vacuum insulation cryogenic equipment - Part 6.Heat-leak rate measurement GB/T 18443.7, Testing method of performance for vacuum insulation cryogenic equipment - Part 7.Holding time measurement 3.6 Static evaporation rate The value of evaporation rate when the test evaporation rate is converted to that under the standard ambient condition, in percent per day (%/d). 4 General requirements 4.1 Environmental conditions 4.1.1 The test environment shall be clean, well ventilated, and shall be provided with anti-static and fire-proof measures. 4.1.2 The test site shall be equipped with warning areas and red signal signs. 4.1.3 The test site shall not have strong electromagnetic interference, strong vibration and shock. 4.1.4 The ambient pressure shall be the local atmospheric pressure, where the temperature range is 0 °C ~ 40 °C, and the relative humidity is less than 85%. 4.1.5 When a flammable and explosive cryogenic liquid is used as the test medium, a safe area shall be set up, and no dangerous source that may cause danger shall exit. 4.2 Test equipment 4.2.1 Basic requirements 4.2.1.1 When the test medium is a flammable and explosive cryogenic liquid, the measured piece and the measuring pipeline shall be provided with necessary anti-static measures, and no open flame shall be generated. 4.2.1.2 The performance, range and accuracy of the instruments and equipment shall meet the test requirements. Measuring instruments and equipment shall be calibrated or verified to be qualified by the national legal measure institute, and shall be used within the validity period of the calibration. 4.2.1.3 After the vacuum insulated cryogenic equipment is filled with cryogenic liquid, in the preparation stage of standing still, an air pipe shall be used to guide the vaporized gas from the vent of the cryogenic container to a designated safe area. The air pipe and each connector shall be well sealed and shall not leak. 4.2.1.4 When the test medium is a flammable medium, use nitrogen or inert gas to replace the relevant connecting pipes first. The vents of the vacuum insulated cryogenic equipment and the exhaust pipes of the safety valve vents shall be connected to the prepared airbags, recycling devices, or safety vents by pipelines. 4.2.1.5 The allowable measurement error of the thermometer is ±1 °C. 4.2.1.6 The allowable measurement error of the atmospheric pressure gauge is ±50 Pa. 4.2.2 Vacuum unit 4.2.2.1 The final vacuum degree of the vacuum unit shall be at least one order of magnitude higher than the vacuum degree of the seal of the measured piece. 4.2.2.2 The effective pumping speed of the vacuum unit shall meet the gas load of the measured piece. 4.2.3 Vacuum gauge and vacuometer 4.2.3.1 The rubber seal connector of the vacuum gauge shall comply with the regulations of JB/T 8105.1; the metal seal connector of the vacuum gauge shall comply with the regulations of JB/T 8105.2. 4.2.3.2 The type and measurement range of the vacuum gauge and the supporting vacuometer shall meet the requirements for vacuum degree of the interspace in the tested vacuum insulated cryogenic equipment; the uncertainty of measurement of the vacuum degree shall be less than 50%. 4.2.3.3 Hot-cathode and cold-cathode ionization vacuum gauges are not allowed to be used in high-vacuum multi-layer insulated cryogenic equipment that is loaded with liquid oxygen or flammable medium. 4.2.3.4 The vacuum interspace of the high-vacuum multi-layer insulated cryogenic equipment - which is loaded with liquid oxygen or flammable medium - can be equipped with a composite gauge combining resistance gauge and ionization vacuum gauge, or be installed with a resistance gauge and an ionization vacuum gauge in parallel. The ionization vacuum gauge can be started for measurement only when the vacuum degree is greater than 10-1 Pa. 4.2.4 Vacuum valve 4.2.4.1 The diameter of the air extraction pipeline connected with the evacuation unit and the vacuum valve on the measured piece shall be larger than that of the vacuum valve on the measured piece. 4.2.4.2 The leak rate of the vacuum valve shall not exceed 1×10-9 Pa·m3/s. 4.2.5 Connecting pipeline The material of the connecting pipeline should be stainless steel, copper or aluminum alloy. 4.3 Measured piece and test medium Appendix A (Normative) Determination of standard heat-leak rate and static evaporation rate of the actually-stored medium A.1 Determine the standard heat-leak rate of the actually-stored medium Where. Qs – standard heat-leak rate of the actually-stored medium, in watts (W); Q20 – standard heat-leak rate of the test medium, in watts (W); Tcos – saturation temperature of the actually-stored medium under standard atmospheric pressure (101.325 kPa), in Kelvins (K); Tcot – saturation temperature of the test medium under standard atmospheric pressure (101.325 kPa), in Kelvins (K). A.2 Determine the static evaporation rate of the actually-stored medium Where. αs – static evaporation rate of the actually-stored medium, in percent per day (%/d); αt – static evaporation rate of the test medium, in percent per day (%/d); Tcos – saturation temperature of the actually-stored medium under standard atmospheric pressure (101.325 kPa), in Kelvins (K); hGot – gas specific enthalpy of the test medium under standard atmospheric pressure (101.325 kPa), in joules per kilogram (J/kg); hLot – liquid specific enthalpy of the test medium under standard atmospheric pressure (101.325 kPa), in joules per kilogram (J/kg); Ft – maximum allowable filling mass of the test medium, in kilograms (kg); ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.