GB 7260.1-2008 PDF in English
GB 7260.1-2008 (GB7260.1-2008) PDF English
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Name of Chinese Standard | Status |
GB 7260.1-2008 | English | 155 |
Add to Cart
|
0-9 seconds. Auto-delivery.
|
[GB/T 7260.1-2008] Uninterruptible power systems (UPS) -- Part 1-1: General and safety requirements for UPS used in operator access areas
| Valid |
GB/T 7260.1-2023 | English | 1194 |
Add to Cart
|
8 days
|
Uninterruptible power systems (UPS) -- Part 1: Safety requirements
| Valid |
Newer version: GB 7260.1-2023 Standards related to: GB 7260.1-2023
PDF Preview
GB 7260.1-2008: PDF in English GB/T 7260.1-2008 (GB 7260.1-2008)
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 29.200
K 85
GB/T 7260.1-2008
Uninterruptible power systems (UPS) –
Part 1-1. General and safety requirements
for UPS used in operator access areas
(IEC 62040-1-1.2002, MOD)
ISSUED ON. MAY 20, 2008
IMPLEMENTED ON. APRIL 01, 2009
Issued by. General Administration of Quality Supervision, Inspection and
Quarantine of the People’s Republic of China;
Standardization Administration of the People’s Republic of
China.
Table of Contents
Foreword ... 3
1 Scope and specific applications ... 5
2 Normative references ... 6
3 Definitions ... 7
4 General conditions for tests ... 12
5 Fundamental design requirements ... 19
6 Wiring, connections and supply ... 27
7 Physical requirements ... 28
8 Electrical requirements and simulated abnormal conditions ... 33
9 Connection to telecommunication networks ... 35
Annex A (normative) Test for resistance to heat and fire ... 36
Annex B (normative) Motor tests under abnormal conditions ... 36
Annex C (normative) Transformers ... 36
Annex D (normative) Measuring instruments for touch-current tests ... 36
Annex E (normative) Temperature rise of a winding ... 36
Annex F (normative) Measurements of clearances and creepage distances . 37
Annex G (normative) Alternative method for determining minimum clearances.
... 37
Annex J (informative) Table of electrochemical potentials ... 37
Annex K (normative) Thermal controls ... 37
Annex H (informative) Guidance on protection against ingress of water and
foreign objects ... 38
Annex L (normative) Backfeed protection test ... 40
Annex M (normative) Examples of reference load conditions ... 42
Annex N (normative) Ventilation of battery compartments ... 47
Annex X (informative) Guidance for disconnection of batteries during shipment
... 51
Foreword
All technical contents of this Part are mandatory.
GB 7260 “Uninterruptible power systems (UPS)” consists of the following parts.
- Part 1-1. General and safety requirements for UPS used in operator access areas;
- Part 1-2. General and safety requirements for UPS used in restricted access
locations;
- Part 2. Electromagnetic compatibility (EMC) requirements;
- Part 3. Method of specifying the performance and test requirements.
This Part of is Part 1-1 of GB 7260.
This Part modifies IEC 62040-1-1.2002 “Uninterruptible power systems (UPS) - Part
1-1. General and safety requirements for UPS used in operator access areas”.
Compare this Part with IEC 62040-1-1.2002, there are the following technical
differences.
4.5.15 of this Part is revised to “Unless otherwise required by the user, the documents,
human-machine interfaces and markings provided to the end user shall use the
standard Chinese.”
In this Part, annexes A, B, C, D, E, F, G, K, L, M and N are normative, annexes H, J
and X are informative.
This Part was proposed by China Electrical Equipment Industry Association.
This Part shall be under the jurisdiction of National Technical Committee on Power
Electronics of Standardization Administration of China (SAC/TC 60).
Responsible drafting organizations of this Part. Emerson Network Power Co., Ltd.,
Shanghai Forward Technology Co., Ltd.
Participating drafting organizations of this Part. Delta Electronic Communications Co.,
Ltd., Qingdao Rectifier Manufacturing Co., Ltd., Xi’an Power Electronics Research
Institute, Qingdao Economic and Technological Development Zone Chuangtong
Technology Development Co., Ltd.
Main drafters of this Part. Qiu Jianqing, Wang Aosheng, Jiang Weishi, Zhang Xifan,
Wei Hongqi, Sui Xueli, Wu Shengzhang, Shao Mingle, Zhou Guanyun, Wang Ying,
Wang Weihui.
Uninterruptible power systems (UPS) –
Part 1-1. General and safety requirements
for UPS used in operator access areas
1 Scope and specific applications
1.1 Scope
This Part of GB 7260 applies to electronic uninterruptible power systems with an
electrical energy storage device in the d.c. link. This Part refers to the relevant contents
of GB 4943-2001 and IEC 60950-1.2001.
The primary function of the uninterruptible power systems (UPS) covered by this Part
is to ensure continuity of an alternating power source. The UPS may also serve to
improve the quality of the power source by keeping it within specified characteristics.
Notes on regional differences in relevant clauses of GB 4943-2001 and IEC 60950-1.
2001 also apply.
This Part is applicable to UPS which are movable, stationary, fixed or for building-in,
for use on low-voltage distribution systems and intended to be installed in any operator
accessible area. This Part specifies requirements to ensure safety for the operator and
layman who may come into contact with the equipment and, where specifically stated,
for the service person.
This Part is intended to ensure the safety of installed UPS, both as a single UPS unit
or as a system of interconnected UPS units, subject to installing, operating and
maintaining the UPS in the manner prescribed by the manufacturer.
This Part does not cover d.c. supplied electronic ballasts (IEC 60924 and IEC 60925),
UPS intended to be installed in separated electrical locations and UPS based on
rotating machines.
The relevant general and safety requirements for UPS installed in restricted access
locations are given in GB 7260.4; electromagnetic compatibility (EMC) requirements
and definitions are given in GB 7260.2.
1.2 Specific applications
Even if this Part does not cover all types of UPS, it may be taken as a guide for such
equipment. Requirements additional to those specified in this Part may be necessary
for specific applications, for example.
...... Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.
|