GB 21551.3-2010 PDF English
Search result: GB 21551.3-2010_English: PDF (GB21551.3-2010)
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Name of Chinese Standard | Status |
GB 21551.3-2010 | English | 70 |
Add to Cart
|
0-9 seconds. Auto-delivery.
|
Antibacterial and cleaning function for household and similar electrical appliances -- Particular requirements of air cleaner
| Valid |
BUY with any currencies (Euro, JPY, GBP, KRW etc.): GB 21551.3-2010 Related standards: GB 21551.3-2010
PDF Preview: GB 21551.3-2010
GB 21551.3-2010: PDF in English GB 21551.3-2010
GB
ICS 97.030
Y 60
National Standard
of the People’s Republic of China
Antibacterial and cleaning function for household and similar
electrical appliances — Particular requirements of air cleaner
ISSUED ON. JANUARY 14, 2011
IMPLEMENTED ON. SEPTEMBER 15, 2011
Issued by. State Administration for Quality Supervision,
Inspection and Quarantine;
Standardization Administration Committee.
Table of Contents
Foreword ... 3
1 Scope ... 4
2 Normative reference document ... 4
3 Terms and definitions ... 4
4 Health and functional requirements ... 5
5 Inspection methods ... 6
6 Marking ... 6
Appendix A ... 7
Foreword
All technical contents in this part are mandatory.
Series of standard GB 21551 “Antibacterial and cleaning function for household and
similar electrical appliances" consist of several parts. Part 1 is general rule. And the other
parts are the special requirements.
This part is Part 3 of GB 21551.
This part shall be read together with GB 21551.1-2008 “Antibacterial and cleaning
function for household and similar electrical appliances - General”.
Appendix A of this part is normative.
This part was proposed by China National Light Industry Council.
This Part shall be centralized by National Household Appliances Standardization
Technical Committee (SAC/TC 46).
The drafting organizations of this part. China Household Electrical Appliances Research
Institute, Environment and Health Related Product Safety Institute of China Disease
Control and Prevention Center, and Beijing Yadu Science and Technology Corporation.
Main drafters of this part. Zhang Tieyan, Liu Fan, Zhang Liubo, and Chen Hui.
This part is the first-time release.
Antibacterial and cleaning function for household and similar electrical
appliances — Particular requirements of air cleaner
1 Scope
This part of GB 21551 specifies health requirements, inspection methods and marking of
antibacterial, sterilization functional aspects for indoor air cleaner (hereinafter referred to
as "air cleaner").
This part applies to household and similar use of the air cleaner with sterilizing function.
2 Normative reference document
The provisions in the following documents constitute provisions of this part, through
reference in GB 21551. For dated reference documents, the subsequent amendments
(excluding corrigendum) or revisions are not applicable to this part. However, all parties
who have entered into agreement based on this part are encouraged to study the
possibility of applying the latest editions. For the undated reference documents, the latest
edition shall be applicable to this part.
GB/T 18801 Air cleaner
GB/T 18883-2002 Indoor air quality standard
GB 19258 Ultraviolet sterilizing lamp
GB 21551.1-2008 General requirement of antibacterial and cleaning function for
household and similar electrical appliances
GB 21551.2-2010 Special requirements of antibacterial and cleaning function for
household and similar electrical appliances
WS/T 206 Method for determination of inhalable particulate in air of public place —
Light scattering method
Technical Standard for Disinfection (Ministry of Health 2002 Edition)
3 Terms and definitions
The following terms and definitions are applicable to this part.
3.1
Air cleaner
In a container, air cleaner is the device that uses of certain technologies or methods (such
as filtration, adsorption, degradation) to significantly reduce the air particles, gaseous
pollutants.
3.2
5 Inspection methods
5.1 Health and safety inspection
5.1.1 Air cleaner itself may produce harmful factors during testing. The test result
value shall be the laboratory testing value MINUS the laboratory environment background
concentration value.
5.1.2 Ozone concentration test at outlet of air cleaner shall adopt UV
spectrophotometer method as specified in Appendix A of GB/T18883-2002.
5.1.3 Ultraviolet leakage strength of air cleaner shall use the test method as specified
in GB19258.
5.1.4 The test of TVOC concentration at outlet of air cleaner shall adopt the thermal
desorption/capillary gas chromatography method in Appendix C of GB/T18883-2002.
5.1.5 The test of PM10 particle concentration at outlet of air shall adopt the light
scattering method as specified in WS/T 206.
5.2 Functional checkout
Sterilization performance’s test method for air cleaner is shown in Appendix A.
6 Marking
6.1 Marking principle
6.1.1 Air cleaner’s product marking shall comply with the requirements of Chapter 5 of
GB21551.1-2008.
6.1.2 In the product instructions, air cleaner shall specifically indicate that the product
possesses the functions, indicators, and cleaning materials replacement OR regeneration
cycle and methods - as specified by this part.
6.2 The using of antibacterial (sterilization), air cleaning function marking
6.2.1 Air cleaner with use marking must meet the related health and safety
requirements of 4.1;
6.2.2 The air cleaner complying with the requirements of 4.2.2 can use the word
"antimicrobial (sterilization)" on the product packaging box and the product nameplate.
Appendix A
(Normative)
Antibacterial (sterilization) function evaluation of air cleaner
A.1 Scope
This Appendix specifies a method to evaluate air cleaner sterilization function.
A.2 Test principle
Within the specified time, respectively determine the bacteria-number’s initial value and
ending value in the contrast group and the test group. And in accordance with the
following 2 formula, calculate the antibacterial and sterilization rate of bacteria and
microorganisms in the air.
Natural extinction rate (%) =
Initial bacteria-number in contrast group - ending bacteria-number in contrast group
×100(%)
Initial bacteria-number in contrast group
Antimicrobial (sterilization) rate (%) =
Initial bacteria-number in test group (1 - natural extinction rate) - ending
bacteria-number in test group
×100(%)
Initial bacteria-number in test group (1 - natural extinction rate)
A.3 Simulation field test
A.3.1 simulation test chamber
a) Ambient temperature of test chamber is 20°C~25°C; relative humidity is RH 50%
~70%
b) Structural requirements of test chamber. Use a pair of aerosol compartments
adjacent to each other. The environment of both compartments (including
temperature, humidity, cleanness, light, sealing and ventilation conditions, etc.)
shall be consistent. And maintain them stable during the experiment. The design
and structure of the test compartments shall ensure that the microbial aerosol is
not compromised; the materials used shall be corrosion resistant, and easy to
clean.
— Volume of the chamber. (3.5mX3.4mX2.5m=30m3);
— Envelop enclosure (including wall, ceiling, floor). It shall use low pollution or
non-pollution and low-adsorption materials (such as stainless steel, PTFE,
tempered glass, etc.);
— The sealing filling materials. Use silicon rubber and glass sealant;
— Air stirring device. Fan;
A.3.3.3 Preparation of bacterial suspension
Staphylococcus albsp suspension is conducted according to disinfection technology
standard (2002 Edition) 2.1.1.2.
A.3.3.4 Test group prototype installation
According to the installation instructions of the measured prototype, install the prototype at
the far-end of the test compartment.
A.3.3.5 The installation of the blank-contrast group prototype
Install one product that is same-model and same-batch as the tested prototype. And
remove all components which have antibacterial and sterilization functions; or set the
functions of antibacterial and sterilization to be “not working” state.
A.3.4 Test procedures
A.3.4.1 Sterilization. The test vessel used in the test is sterilized.
A.3.4.2 The aerosol compartment’s air is cleaned and sterilized through high efficiency
filter. The cleanliness is not less than grade-7 (grade-10000).
A.3.4.3 Adjust temperature and relative humidity of the aerosol compartment. Maintain
stability for a period of time (so as to ensure that the entire experiment is relatively
constant for temperature and relative humidity). Then seal the aerosol compartment. It
must not be opened during the test.
A.3.4.4 Open the air supply device in the operating room. Blow in the circulating air
which has been filtered by high efficiency filter, Maintain the air pressure in operating room
at positive pressure (15Pa ~ 30Pa), so as to prevent microbial aerosol in test
compartment from leakage.
A.3.4.5 Take the test bacterial suspension. Dilute to the desired concentration with
nutrient broth. According to with the setting pressure, gas flow rate and spray time of the
spraying bacteria device, spray bacteria. It is required to stir with air stirring equipment
(such as fans) while spraying. After bacterial spraying is complete, it is required to stir for
10 min. Then stand for 15 min.
A.3.4.6 At the same time, respectively conduct bacterial concentration sampling to the
experimental group and contrast group. Sampling time is 1 min ~ 5 min Sampling head
shall be upward when sampling. The positive contrast bacteria-number in the air of
aerosol chamber is requ...
...... Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.
|