HJ 101-2019 PDF English (HJ/T 101-2003: Older version)


Search result: HJ 101-2019 (HJ/T 101-2003 Older version)
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
HJ 101-2019225 Add to Cart Auto, < 3 mins Technical specifications and test procedures for water quality on-line automatic monitoring equipment of ammonia Valid
HJ/T 101-2003359 Add to Cart 3 days The technical requirement for water quality automatic analyzer of ammonia Obsolete

Similar standards: GB 5085.7   GB 5085.1   HJ 609   

HJ101-2019: PDF in English

HJ/T 101-2019 NATIONAL ENVIRONMENTAL PROTECTION STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA Replacing HJ/T 101-2003 Technical specifications and test procedures for water quality on-line automatic monitoring equipment of ammonia ISSUED ON: DECEMBER 24, 2019 IMPLEMENTED ON: MARCH 24, 2020 Issued by: Ministry of Ecology and Environment Table of Contents Foreword ... 3 1 Scope ... 5 2 Normative references ... 5 3 Terms and definitions ... 6 4 Technical specifications ... 9 5 Performance indexes and test methods ... 13 6 Operating manual ... 22 Technical specifications and test procedures for water quality on-line automatic monitoring equipment of ammonia 1 Scope This Standard specifies the technical specifications, performance indexes and test methods for water quality on-line automatic monitoring equipment of ammonia. This Standard applies to guiding production and design, guiding to application type- selection and implementing performance test. The measuring range of water quality on-line automatic monitoring equipment of ammonia shall include 0.1 mg/L ~ 150 mg/L, which can satisfy the monitoring requirements for underground water, surface water, domestic wastewater and industrial wastewater. 2 Normative references This Standard referenced the following documents or clauses therein. For undated references, the latest edition of the referenced documents (including all amendments) applies to this document. GB/T 9969, General principles for preparation of instructions for use of industrial products GB/T 13306, Plate HJ 212, Data transmission standard for online monitoring systems of pollutant HJ 535, Water quality – Determination of ammonia nitrogen – Nessler reagent spectrophotometry HJ 536, Water quality-Determination of ammonia nitrogen – Salicylic acid spectrophotometry expressed as relative standard deviation, provided that no unplanned artificial maintenance and correction is carried out for instruments. 3.7 low level drift in 24 h The mean value of the deviation absolute value between measured value and initial value of instruments for the continuous measurement (0 ~ 20%) of upper limit of the test range of a low concentration reference solution at specified periods, provided that no unplanned artificial maintenance and correction is carried out for instruments. 3.8 high level drift in 24 h The percentage of the mean value, in relation to the upper limit of the test range (80% ~ 100%), of the deviation absolute value between measured value and initial value of instruments for the continuous measurement (0 ~ 20%) of upper limit of the test range of a high concentration reference solution at specified periods, provided that no unplanned artificial maintenance and correction is carried out for instruments. 3.9 memory effect The degree of interference of the residues in the tubes of instruments on the next result of measurement after the measurement of some reference solution or sample using instruments. 3.10 interference of voltage The deviations of measured values, which are obtained in the measurement of the same reference solution using instruments under different supply voltages, from measured value under reference voltage (220 V). 3.11 interference of pH The deviation of measured values, which are obtained from the measurement of a reference solution using instruments under different pH values, from measured value from the measurement of a neutral reference solution (pH = 7). 3.12 management, data and running log query and output, and so on; meanwhile, they have such functions as sample reservation triggering sampling. Control units are capable of providing corresponding communication protocols when performing the above- mentioned functions, and such communication protocols satisfy the requirements of HJ 212. 4.2 Environmental conditions for service Environmental temperature: 5°C ~ 40°C; Relative humidity: 65% ± 20%; Supply voltage: alternating voltage 220 V ± 22V; Supply frequency: 50 Hz ± 0.5 Hz; Water sample temperature: 0°C ~ 50°C. 4.3 Appearance requirements 4.3.1 The marking of instruments shall be as specified in GB/T 13306. Plates shall be affixed to an appropriate, visible position. Plates shall include the following content: a) category of power supply; b) name and address of manufacturer; c) name and specifications of instruments; d) factory number; e) manufacturing date; f) test range and limit of quantitation; g) limit of quantitation; h) environmental conditions for service. 4.3.2 The monitor shall be free from stains and damages. All display interfaces shall be in Chinese and the characters uniform and clear; the screen shall be free from dark corners, black spots, rainbows, bubbles, flickers, etc.; it is capable of finishing all operations according to the instructions of the monitor. 4.3.3 The enclosure shall be made of corrosion resistant materials; the surface shall be free from crack, deformation, contamination, burr, etc.; the coating of the surface shall be uniform, without corrosion, rust, shedding or abrasion. 4.4.4.2 The output signals of test modules shall be stable. 4.4.4.3 Signal converters shall have the function to convert measured values into a corresponding quantity of electric signals (4 mA ~ 20 mA DC or RS232/RS485 interfaces). 4.4.4.4 The test period shall not be greater than 60 min. 4.4.5 Control units 4.4.5.1 They shall have the timed test function. 4.4.5.2 They shall have the manual and automatic cleaning function for the units including sample introduction/measurement, physical/chemical pretreatment and analysis and test. 4.4.5.3 They shall have the manual and automatic correction function; they are capable of setting automatic correction period. 4.4.5.4 They shall have the automatic reference sample inspection function. 4.4.5.5 If they have multiple measuring ranges, they shall have the automatic measuring range switching function; instruments display the final results of measurement. 4.4.5.6 They shall be capable of automatic acquisition, storage, processing, query, display, output, etc. of all data, instruments’ parameters and running logs. 4.4.5.7 They shall store initial data and running logs for at least 12 months. 4.4.5.8 They shall have the function to add marks for different test data; the specific marks shall be as specified in HJ 212. 4.4.5.9 The unit of measured results of instruments shall be mg/L, which shall be rounded off to the second decimal place. 4.4.5.10 They shall have the digital quantity communication interfaces; output instructions, relevant data and running logs through the digital quantity communication interfaces; can receive the remote control instructions of the platform, at least including remote start, remote time setting function. 4.4.5.11 Data transmission shall be accompanied by communication protocols, as specified in HJ 212. 4.4.5.12 They shall realize the serial port output and internet access output of monitored data. of ammonia standard stock solution. 5.3.3 Other reagents: to be provided by the manufacturer of instruments. 5.4 Test preparation and correction 5.4.1 Check all parts of instruments; adjust instruments to the normal working condition. 5.4.2 Check all reagents of instruments; ensure they are sufficient and that their quality is as specified. 5.4.3 After switching on, preheat in accordance with the preheating time specified in the operating manual provided by the manufacturer of instruments, making all parts function stably. 5.4.4 In accordance with the correction method specified in the operating manual provided by the manufacturer of instruments, use ammonia standard stock solution (5.3.2) to prepare standard solution of the concentration specified for instruments. 5.5 Test method for basic test range 5.5.1 Indication error During the normal running period of instruments, test three standard solutions of ammonia concentrations about 2 mg/L, 5 mg/L and 8 mg/L; test each solution consecutively for n (n = 6) times; calculate the relative error of the mean value of the n (n = 6) measured values in relation to the concentration of standard solution. Calculate the indication error Re for each time. where, Re – the indication error, in %; x – the mean value of n measurements for each concentration, in mg/L; ρ – the concentration of ammonia standard solution, in mg/L. 5.5.2 Limit of quantitation During the normal operating period of instruments, test standard solution of ammonia concentration about 0.1 mg/L for n (n = 7) times; in accordance with Equation (1), calculate the indication error Re of n (n = 7) measured values; in accordance with Equation (2), calculate the standard deviation S of the n (n = 7) measured values; in accordance with Equation (3), calculate the limit of quantitation of instruments LOQ. where, T – the memory effect, in mg/L; Xi – the measured value of the ith measurement, in mg/L. 5.5.7 Interference of voltage test During the normal operating period of instruments, use standard solution of ammonia concentration about 8 mg/L to carry out measurement for 3 times under the initial voltage 220 V; adjust the voltage to 242 V and measure the same standard solution for 3 times; adjust the voltage once again to 198 V and measure the same standard solution for 3 times. Use the mean value of 3 measured values under 220 V; in accordance with Equation (8), calculate respectively the relative error ΔV of the mean value Vi of 3 measured values under 242 V and 198 V, in relation to Vs; use the larger absolute value as the value of interference of voltage test. where, ΔV – the interference of voltage, in %; Vi – the mean value of 3 measured values under some voltage, in mg/L; Vs – the mean value of 3 measurements under 220 V, mg/L. 5.5.8 Interference of pH test During the normal operating period of instruments, use standard solution of ammoni.......
Source: https://www.ChineseStandard.net/PDF.aspx/HJ101-2019