GB/T 32483.3-2016 English PDFUS$254.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 32483.3-2016: Energy performance of lamp controlgear -- Part 3: Controlgear for halogen lamps and LED modules -- Method of measurement to determine the efficiency of the controlgear Status: Valid
Basic dataStandard ID: GB/T 32483.3-2016 (GB/T32483.3-2016)Description (Translated English): Energy performance of lamp controlgear -- Part 3: Controlgear for halogen lamps and LED modules -- Method of measurement to determine the efficiency of the controlgear Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: K74 Classification of International Standard: 29.140.99 Word Count Estimation: 13,144 Date of Issue: 2016-02-24 Date of Implementation: 2016-09-01 Quoted Standard: IEC 61047-2004; IEC 61347-1-2007; IEC 61347-1-2007/AMD 1-2010; IEC 61347-1-2007/AMD 2-2012; IEC 61347-2-2; IEC 61347-2-13; IEC 61558-1; IEC 61558-2-6; IEC GUIDE 115-2007 Adopted Standard: IEC 62442-3-2014, IDT Regulation (derived from): National Standard Announcement No Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the method of measuring the power loss of the inductive transformer and the stand-by power loss of the electronic converter of the halogen lamp and the LED module. At the same time, a calculation method is provided for the efficiency of the control device of the halogen lamp and the LED module. This standard applies to electrical control devices consisting solely of control devices and lamps - lamp circuits. For multi-purpose power supply only consider the lighting part. This standard is applicable to the measurement of the total input power and standby power of all control devices for household and general commercial lighting, halogen lamps and LED modules, as well as for calculating the efficiency of control devices. This standard does not apply to: constitute the overall lamp control device; control circuit in the case of series capacitance; controllable wire wound inductive control device. GB/T 32483.3-2016: Energy performance of lamp controlgear -- Part 3: Controlgear for halogen lamps and LED modules -- Method of measurement to determine the efficiency of the controlgear---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Energy performance of lamp controlgear. Part 3. Controlgear for halogen lamps and LED modules.Method of measurement to determine the efficiency of the controlgear ICS 29.140.99 K74 National Standards of People's Republic of China Lamp control device efficiency requirements Part 3. halogen lamps and LED modules Method for measuring the efficiency of control devices Energyperformanceoflampcontrolgear-Part 3. Controlgearforhalogen (IEC 62442-3..2014, IDT) 2016-02-24 released 2016-09-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Management Committee released Directory Preface III 1 Scope 1 2 normative reference document 1 3 Terms and definitions 2 4 General requirements 3 4.1 Applicability 3 4.2 General precautions for testing 4 4.3 Controllable control device 4 4.4 Measurement Uncertainty 4 4.5 Sampling of the controlled control device 4 4.6 Number of samples 4 4.7 Power supply 4 4.8 Power supply voltage waveform 4 4.9 alternative load 5 4.10 Thermocouple Temperature Indicator 5 4.11 Instrument Accuracy 5 4.12 measuring circuit 5 4.13 multi-rated voltage control device 5 4.14 multi-power output control device 6 5 Halogen lamp and LED module control device (transformer, converter) the efficiency of the measurement and calculation method 6 5.1 Measuring device. input and output power 6 5.2 Inductive (transformer) and electronic (converter) control device efficiency calculation 6 5.3 Measuring device. Input power in off mode 7 5.4 Electronic control unit - Standby power measurement of the converter 7 Reference 9 Figure 1 Inductance control device (transformer) Power measurement settings and converters (electronic control device) Input and output power measuring device 6 Figure 2 Inductive control device (transformer) and converter (electronic control device) Input power measurement device 7 Figure 3 electronic control device - converter standby power measurement device 7 Table 1 Typical nominal power supply data for some areas 4 ForewordGB/T 32483 "Light control device efficiency requirements" plan to publish 3 parts. - Part 1. Fluorescent lamp control device control device line total input power and control device efficiency measurement method; - Part 2. Measurement methods for the efficiency of control devices for high intensity gas discharge lamp control devices (except fluorescent lamps); Part 3. Methods for measuring the efficiency of control devices for halogen tungsten and LED modules. This part is part 3 of GB/T 32483. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This part uses the translation method equivalent to the use of IEC 62442-3..2014 "Lamp control device efficiency requirements Part 3. Halogen lamps and LED module control device efficiency measurement method ". In this part of the normative reference to the international documents have a consistent correspondence between the following documents. Performance requirements for dc/AC electronic buck converters for tungsten filament GB/T 19654-2005 (IEC 61047..1991, IDT) Control devices for lamps - Part 1. General requirements and safety requirements (IEC 61347-1..2007, IDT) Control device for lamps - Part 3. Particulars for DC/AC electronic buck converters for tungsten filament lamps GB/T (IEC 61347-2-2..2006, IDT) Control devices for lamps - Part 14. Particulars for DC or AC electronic control devices for LED modules Special requirements (IEC 61347-2-13..2006, IDT) Safety of power transformers, power supplies, reactors and similar products - Part 1. General requirements and tests - GB 19212.1-2008. (IEC 61558-1..2005, IDT) --- GB 19212.7-2012 Transformers, reactors, power supply units and similar products with supply voltage of 1100V and below Part 7. Particular requirements and tests for power isolators for safety isolating transformers and built-in safety isolating transformers (IEC 61558-2-6..2009, IDT) This part is made by the China Light Industry Federation. This part of the National Lighting Standardization Technical Committee (SAC/TC224) centralized. This part of the drafting unit. Hangzhou heyday Technology Instrument Co., Ltd., Hengdian Group was state Lighting Co., Ltd., Shenzhen Yu Fu lighting Co., Ltd., Wenzhou City Quality and Technical Supervision and Inspection Institute, Hangzhou Hongyan Electric Co., Ltd., Hangzhou Anderson Electronics Co., Ltd., Zhejiang crystal day lighting Technology Co., Ltd., Beijing Electric Light Source Research Institute. The main drafters of this part. Hou Minxian, Nie Lixun, Huang Shanshi, Cao Xiaobing, Sun Quanming, Wu Zhaoming, Yu Jianming, Fu Chuangye, Duan Yanfang, Zheng yanfeng Lamp control device efficiency requirements Part 3. halogen lamps and LED modules Method for measuring the efficiency of control devices1 ScopeThis part of GB/T 32483 specifies the power loss of the inductive transformers of the halogen and LED modules and the standby of the electronic converter Measurement of power loss. At the same time, for the halogen lamp and LED module control device efficiency defines a calculation method. This section applies to the electrical control unit - lamp line consisting only of the control unit and the lamp. For the multi-purpose power supply only consider the part of the lighting. Note. It is not included in the production process to test the requirements of individual control devices. This section applies to the total input power and standby power of all control devices for home and general commercial lighting, halogen lamps and LED modules The measurement method, and the calculation method of the control device efficiency. This section does not apply to. - a control device that constitutes a monolithic lamp; --- control circuit in the case of series capacitance; --- Controlled wire wound inductive control device.2 normative reference documentsThe following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. IEC 61047..2004 DC/AC electronic buck converter for tungsten filament performance requirements (DCorAC.suppliedelectronic step-downconvertorsforfilamentlamps-Performancerequirements) IEC 61347-1..2007 Lamp control devices - Part 1. General requirements and safety requirements (Lampcontrolgear - Part 1. Generalandsafetyrequirements) AMD1..2010 AMD2..2012 IEC 61347-2-2 Lamp controlgear - Part 2-2. Particular requirements for dc or AC powered electronic buck converters for tungsten filament lamps (Lampcontrolgear-Part 2-2. Particularrequirementsford.c.ora.c.suppliedelectronicstep-downcon- vertorsforfilamentlamps IEC 61347-2-13 Lamp control devices - Part 2-13. Particular requirements for DC or AC electronic control devices for LED modules (Lampcontrolgear-Part 2-13. Particularrequirementsford.c.ora.c.suppliedelectroniccontrolgear forLEDmodules) IEC 61558-1 Safety of power transformers, power supplies, reactors and similar products - Part 1. General requirements and tests ofpowertransformers, powersupplies, reactorsandsimilarproducts-Part 1. Generalrequirements andtests) IEC 61558-2-6 Safety of transformers, reactors, power supply units and similar products with supply voltages of 1100V and below Section 2-6 of Safety . Special requirements and tests for safety isolating transformers and power supply units with built-in safety isolating transformers (Safetyoftransformers, re- ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 32483.3-2016_English be delivered?Answer: Upon your order, we will start to translate GB/T 32483.3-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 32483.3-2016_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 32483.3-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |