GB 22370-2008 English PDFUS$509.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 22370-2008: Fire alarm and safety system for household Status: Valid
Basic dataStandard ID: GB 22370-2008 (GB22370-2008)Description (Translated English): Fire alarm and safety system for household Sector / Industry: National Standard Classification of Chinese Standard: C81 Classification of International Standard: 13.220.20 Word Count Estimation: 22,226 Date of Issue: 2008-09-01 Date of Implementation: 2009-05-01 Quoted Standard: GB/T 156; GB 4208-1993; GB 4706.1-1998; GB 4715; GB 4716; GB 9969.1 Regulation (derived from): Announcement of Newly Approved National Standards No. 16 of 2008 (No. 129 overall) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This Chinese standard specifies the home fire safety system and the system components, general requirements, requirements and test methods, inspection rules, marks. This standard applies to home fire safety systems installed. GB 22370-2008: Fire alarm and safety system for household---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Fire alarm and safety system for household ICS 13.220.20 C81 National Standards of People's Republic of China Home Fire Safety Systems Posted 2008-09-01 2009-05-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsIntroduction Ⅲ 1 Scope 1 2 Normative references 1 3 system components 1 4 1 General requirements 5 Requirements and test methods 8 16 6 Inspection Rules 7 logo 17ForewordThe fourth through seventh chapter of this standard is mandatory, the rest are recommended. The standard proposed by the People's Republic of China Ministry of Public Security. This standard by the National Standardization Technical Committee of the Sixth Fire Technical Committee. This standard is drafted by. Ministry of Public Security Shenyang Fire Research Institute. Participated in the drafting of this standard. Qinhuangdao Fortis electronic Enterprises Ltd., Shenzhen-Anderson Electronics Co., Ltd., Gulf Security Technology Ltd., Shenzhen given the security system Limited. The main drafters of this standard. Ding Hongjun, Zhang Ying Cong, with Rui Tao, Wang Jiangang, Chen Nan, Guan Wei, Zhou, safe ice, Liu Changan, Lin Qiang. This standard is the first release. Home Fire Safety Systems1 ScopeThis standard specifies the home fire safety system, system components, general requirements, requirements and test methods, inspection rules and signs. This standard applies to fire safety systems for home installation.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 156 standard voltage GB 4208-1993 enclosure class GB 4706.1-1998 household and similar electrical appliances - Part 1. General requirements (eqv IEC 335-1.1991) GB 4715 point-type smoke detectors GB 4716 point type heat detectors GB 9969.1 Instructions General Industrial Products GB 12978 fire electronic products inspection rules GB 14287.2 electrical fire control system - Part 2. residual current electric fire detectors GB 16838 fire electronic products environment test methods and severities3 system componentsHome fire safety system in the practical application of the process according to the specific circumstances of the protected object can be divided into the following four types. --- A Class. Home Fire safety system with centralized control and centralized management functions, suitable for centralized small residential property management Area. System, automatic fire alarm system at least by the general industrial and civil use of fire alarm controller, fire Detectors, manual fire alarm switch and alarm sound composition; or at least by a fire alarm controller, household fire detectors, manual Alarm switches and other equipment. --- Class B. with a centralized regulatory functions of home fire safety systems, adapted to centralized property management of residential quarters. At least Control center monitoring equipment, home fire alarm controllers, home fire detectors, manual alarm switch composition, typically include monitoring Pipe alarm, remote control switches and other equipment. --- Class C. no centralized regulatory functions of home fire safety systems, adapted to no centralized property management has been put into residential or Residential use. At least by the home fire alarm controller, household fire detectors, manual alarm switch composition, typically include Supervision alarm, remote control switches and other equipment. --- Class D. no centralized regulatory functions of home fire safety systems, adapted to no centralized property management has been put into residential or Residential use. Independent smoke detection alarm, stand-combustible gas detectors and other equipment. Note. fire detectors including smoke detectors, heat detectors, combustible gas detectors, residual current electric fire detectors.4 General requirementsHome Fire Safety System 4.1 General Requirements 4.1.1 General Home fire safety system consisting of various types of equipment, in addition to Class A home fire safety systems fire alarm controller, fire detectors, Class D fire alarm sound and home fire safety system independent smoke detection alarm shall be otherwise provided in the relevant standards, which He Devices To comply with this standard, should first meet the relevant requirements of this chapter, then press the test specified in Chapter 5, and meet the requirements of the test. 4.1.2 The main component performance requirements 4.1.2.1 Basic requirements The main part of household fire safety systems of various types of equipment, should comply with the relevant national standards of styling products, and should meet the following Requirements. 4.1.2.2 Indicator 4.1.2.2.1 should be color-coded red to indicate an alarm signal; yellow indicates a fault, shielded, loop self-test system abnormality; green table It shows the main power supply and standby power supply is working properly. 4.1.2.2.2 indicator should be marked function. 4.1.2.2.3 In 5lx ~ 500lx ambient light conditions, in front of 22.5 ° angle range, function and power LEDs should 3m place clearly visible; the other indicators should be clearly visible at 0.8m. 4.1.2.2.4 use flashing mode indicator (device) is lit each time should not be less than 0.25s, which start signal indicator (unit) flashing frequency Rate should not be less than 1Hz, malfunction indicator lamp (device) flashing frequency should not be less than 0.2Hz. 4.1.2.2.5 An indicator light display simultaneous fault, shielding three functions and self-test, fault indication should be shiny, shield and self-test instructions It should be steady. 4.1.2.3 letter (character) - Digital Display In 5lx ~ 500lx ambient light conditions, the characters should be displayed in front of 22.5 ° viewing angle, 0.8m at readable. 4.1.2.4 Fuse For power line fuses or other overcurrent protection devices, the rated current value should generally be no more than 2 times the maximum operating current. When the maximum operating current is greater than 6A, the fuse rated current value can be 1.5 times. Close at fuse or other overcurrent protection devices It should be clearly marked its parameter values. 4.1.2.5 Terminals On each of the terminals should be clear, firmly marked number or symbol corresponding use shall be stated in the relevant documents. 4.1.2.6 Standby Power 4.1.2.6.1 The positive power supply wire connection is red, very negative black or blue. 4.1.2.6.2 Power backup battery charge and discharge times when, without exceeding the limits specified by the manufacturer of the discharge situation, should be able to Within 24h battery charge to more than 80% of rated capacity, then charge should be filled after 48h. 4.1.2.6.3 standby power lower than the over-discharge protection voltage battery voltage warning should be issued. 4.1.2.7 switches and buttons (button) Switches and buttons (button) (on which or near a position) should be clearly marked function. 4.1.2.8 wires and strips Home fire safety systems in the main circuit wiring a home fire alarm control parameter is greater than the operating temperature should be 105 ℃ flame guide Line (or cable), and the wires are securely; trunking should be used to connect non-combustible materials or flame retardant materials (oxygen index of not less than 28) Manufacturing. 4.1.2.9 element temperature Home fire safety systems inside various types of equipment, mainly electronic, electrical components of the maximum temperature rise should not exceed 60 ℃. Ambient temperature The maximum surface temperature (25 ± 3) ℃ under conditions built-in transformer, ballast and other heat-generating components should not exceed 90 ℃. Around the battery (do not touch And battery) Maximum ambient temperature should not exceed 45 ℃. 4.1.3 Degree of protection Enclosure class home security systems of various types of fire equipment shall comply with the requirements of IP30 in GB 4208-1993. 4.1.4 User's Guide Home fire safety systems of various types of equipment should be a corresponding Chinese instructions. Prospectus shall meet the requirements of GB 9969.1, with Consistent product performance. 4.1.5 Communication Protocol Communication between the various types of equipment household fire safety system should be adopted standard communication protocol, the agreement should meet domestic standards. 4.1.6 System Compatibility Home fire safety system operating voltage range of performance indicators of various types of devices, operating current range, alarm thresholds, etc. should be consistent, After the components of the system, the system should meet the functional and 5.14 ~ 5.19 4.2.2,4.2.3,4.10 requirements. 4.2 Household fire alarm controller 4.2.1 General requirements 4.2.1.1 household fire alarm control main power should be 220V, 50Hz AC power supply, power line input terminals should be located. 4.2.1.2 metal shell household fire alarm controller should be provided with a protective ground terminal. 4.2.1.3 household fire alarm controller should be able to connect to its power supply components (except wireless systems), DC voltage should be consistent GB/T 156 provides priority DC 12V or 24V. 4.2.1.4 household fire alarm control test performance should be consistent with the provisions of 5.11 ~ 5.26. 4.2.1.5 household fire alarm control function should have Chinese labels; text display when using the information, you should use Chinese. 4.2.2 Fire Alarm 4.2.2.1 household fire alarm controller should be set up for special fire alarm status indicator, no matter what kind of home fire alarm controller is like State, as long as there is a fire alarm signal is input, the LED should light up. 4.2.2.2 household fire alarm controller should be able to receive and display are smoke detectors in the system, heat detectors, combustible Gas detectors, residual current detectors and manual alarm switch triggers fire alarm and other items send out a fire alarm signal in the 10s within Issued a fire alarm sound and light signals, and to keep the manual reset. 4.2.2.3 fire alarm signal should be able to eliminate the manual, and then when there is a fire alarm signal input, should be able to start again. After 4.2.2.4 household fire alarm controller will send a fire alarm signal, at least two output contacts should be initiated at a predetermined time, the contact parameters Number shall comply with the product specification requirements. 4.2.2.5 household fire alarm controller has inbound and voice answering function and/or image display function, a fire alarm signal is issued , It should be able to control its corresponding anti-theft locks open automatically. 4.2.3 regulatory functions 4.2.3.1 Regulatory alarm function (only applicable to domestic fire alarm controller has this feature) 4.2.3.1.1 household fire alarm controller has a regulatory function should have set alarm and alert features deregulation and signifier It shows regulatory state of alert. 4.2.3.1.2 after the regulatory state of alert, home fire alarm controller alarm signal in the regulatory alarms, monitoring should be issued in the 10s Pipe alarm sound and light signal indicating the type of alarm, and to keep the manual reset. 4.2.3.1.3 supervision alarm signal should be able to eliminate the manual, and then when there is supervision alarm signal input, should be able to start again. 4.2.3.1.4 household fire alarm controller after deregulation alert, should not receive regulatory alarm alarm signal is issued, and It should not affect the fire alarm. 4.2.3.1.5 household fire alarm controller when setting up the regulatory state of alert is not successful, there should be sound cue, the acoustic signal should be able to manually eliminate. 4.2.3.2 household management function (only applicable to domestic fire alarm controller has this feature) 4.2.3.2.1 household fire alarm controller has a video image display should be within 3s after receipt of a trigger signal corresponding to the display Image information; image information should be clear, the use of analog audio and video image processing should meet the requirements of Table 1, the use of digital audio and video image processing Shall comply with the requirements of Table 2. Table 1 images require processing of analog audio and video Display Type black and white display color LCD Image Requirements Video signal. PAL standard composite video signal of the video signal. PAL standard composite video signal Signal amplitude. 1VP-P signal amplitude. 1VP-P Input impedance. 75Ω input impedance. 75Ω Full screen maximum brightness. ≥100cd/m2 maximum brightness full screen. ≥250cd/m2 Gradation. ≥8 grade Contrast. ≥250.1 Horizontal Resolution. ≥320 TV Lines pixel matrix. horizontal ≥480 points in the vertical direction ≥234 point Requirements Table 2 image processing of digital audio and video Video signals JPEG, M-JPEG, MPEG2MPEG4 ≥320 × 234 resolution Frame rate ≥1 frames/s BER ≤10-6 Full screen maximum brightness ≥250cd/m2 Audio signal rate ≤128kBps Audible mention within 3s after 4.2.3.2.2 home fire alarm controller has the audio and answer the incoming call function should trigger signal is received Shown signal, and can answer after manual operation and a voice message, call audio performance should be consistent with the requirements in Table 3. Table 3 Audio talk performance Audio talk performance requirements Call the main channel, the transponder channel audio response within the range of 300Hz ~ 3400Hz, 1000Hz relative amplitude variation should be ± 3dB Call the main channel, the channel response harmonic distortion harmonic distortion should be less than 5% SNR Response channel signal to noise ratio should not be less than 35dB Call the main channel signal to noise ratio should not be less than 40dB Audio output power without distortion Response channel audio output without distortion power should not be less than 100mW Call the main channel audio output without distortion power should not be less than 5mW Channel input level requirements Response channel input level should be less than 40mV Call the main channel input level should be less than 30mV Ringing voltage is not less than 70dB (A) 4.2.3.3 lighting, electrical control 4.2.3.3.1 household fire alarm controller with lighting control, electrical control functions should be able manual, timing, and other remote control Achieve lighting, household appliances turned off, and manufacturers meet the proposed control requirements. 4.2.3.3.2 household fire alarm control after lighting, electrical control signal is issued, the accused device shall act within 3s. 4.2.3.3.3 controller short circuit breaker and its control cable lighting, electrical devices should not affect the control and monitoring of fire alarm Pipe alarm. 4.2.3.4 cell information communication Household fire alarm controller having a communication function of the cell should be able to have two-way communication between the household and community management center, and communication When using a text message, it should include Chinese; household fire alarm controller with voice mail should be able to meet the requirements made by the manufacturer. 4.2.4 Communication Function 4.2.4.1 household fire alarm controller should have at least two phone numbers are stored and automatically dial function. 4.2.4.2 household fire alarm controller under fire alarms and alarm state regulators should be able to automatically dial telephone in accordance with the design process. 4.2.4.3 household fire alarm controller should be able (through the relevant parts) with a control center monitoring devices to communicate, the system's various newspaper Police send status information to the control center monitoring equipment; information control center monitoring equipment and household fire alarm controller should be synchronized; household fire Disaster alarm controller before receiving the control center monitoring equipment should continue to transmit a predetermined reply signal information. 4.2.4.4 household fire alarm controller in communication distance specified by the manufacturer shall be associated components, control centers monitoring equipment properly communication. 4.2.5 Fault alarm 4.2.5.1 When the following faults occur when using wired communications household fire alarm controller should a fault audible signal in the 100s, And indicates the type of fault; failure sound and light signals using wireless home fire alarm controller should be sent within 24h, and indicate a fault class Type; fault acoustic signal should be able to eliminate the manual, then a fault signal is input, it should start again; fault signal light should be kept to troubleshooting. a) the communication failure to the connection between the parts; b) to alternate between the power source (battery) charger for charging and standby power cable open circuit, short circuit; c) between its load standby power cable open circuit, short circuit; d) the main power supply undervoltage. Fault signal 4.2.5.2 household fire alarm controller in troubleshooting, you should be able to automatically or manually reset. After the reset, the reported home fire Police should re-display controller, there are still faults within 24h. 4.2.5.3 household fire alarm controller when the main power fails, should be able to automatically switch to standby power supply; the standby power supply can not be guaranteed Their normal work, should a fault acoustic signal and holding more than 1h; when the main power is restored, should automatically switch to the main power supply; the Lord, Backup power conversion should not cause it to false alarm or malfunction. 4.2.5.4 household fire alarm control any of the fault shall not affect the normal operation of the non-defective part. 4.2.5.5 household fire alarm controller and cable fault between the non-fire alarm device shall not affect the fire alarm. 4.2.6 Self-test function During a home fire alarm controller should be able to perform a functional check of the unit (hereinafter referred to as self-test), self-test, subject to the external device and output control The contacts are not movement; self-test or self-test can not be longer than 1min automatically stop its non-self-test site, the detection area and the fire itself Alarm function should not be affected. 4.2.7 information display, query functions Using numbers, letters, display the working status of household fire alarm controller should show fire alarm, alarm and other state regulatory sequence Arrangement information display in descending grade, high-grade display status information should be given priority, low-grade status display shall not affect the high-level state Information display, information display should be consistent with the corresponding state and easy to identify. When home fire alarm controller is a high-level state Display, should be able to manually query othe...... |