YBB 00052005-2015: Halogenated Butyl Rubber Stopper for Injectable Sterile Powder---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/YBB00052005-2015
YB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
Halogenated butyl rubber stopper
for injectable sterile powder
Halogenated butyl rubber stopper
for injectable sterile powder
This standard applies to chlorinated or brominated butyl rubber stoppers
(excluding dry stopper for freezing purposes) that are in direct contact with
injectable sterile powder.
[Appearance] TAKE several of this product, PERFORM inspection in
accordance with Table 1, it shall comply with requirements.
[Identification]* (1) WEIGH 2.0 g of the product, CUT it into small particles,
PLACE it in a crucible, ADD 2.0 g of sodium bicarbonate to cover the specimen
evenly, PLACE it on the electric stove, slowly HEAT it to carbonization, LET it
cool, PLACE it in the muffle furnace to heat it to 300 °C until completely ashed.
After removal, COOL it to room temperature, ADD 10 ml of water to dissolve,
FILTER it, CONTINUE taking 1.5 ml of filtrate, PLACE it in a test tube, ADD
nitric acid, ADD 1 drop of silver nitrate solution, it shall produce white or pale
yellow precipitate.
(2) TAKE appropriate amount of this product, MAKE determination in
accordance with the method IV of Packaging materials infrared spectrometry
(YBB00262004-2015), it shall be basically consistent with the control map.
[Punch chip] TAKE appropriate amount of this product, MAKE determination
in accordance with the method II of Injection stopper and gasket chip
determination method (YBB00332004-2015). The number of chips shall not
exceed 5.
[Puncture force] TAKE 10 of this product, MAKE determination in accordance
with the method II of Rubber stopper for injection and the gasket puncture force
measurement method (YBB00332004-2015). The force required to puncture
the stopper is not more than 10 N.
[Adhesiveness between rubber stopper and container] TAKE 10 of this
product, PLACE it in a beaker, ADD water, BOIL for 5 minutes, REMOVE it,
DRY it at 70 °C for 1 hour. PREPARE for use. In addition, TAKE 10 matching
injection bottles, ADD water to the marked capacity. USE the above stopper to
plug it tightly, ADD the matching aluminum cap, PRESS the cap. PLACE it in
an autoclave at 121 °C ± 2 °C for 30 minutes, COOL it to room temperature,
ALLOW it to stand for 24 hours. Inversely PLACE the above sample, PLACE it
in a container with a 10% methylene blue solution with a suction device,
VACUUM it to a vacuum of 25 kPa, MAINTAIN this pressure for 30 minutes,
and cooled water to dissolve and dilute it to 1000.0 mL, this product shall be
prepared before use), ADD 7 ml of blank solution and 1 ml of 2 mol/L
hydrochloric acid and 3 drops of potassium ferrocyanide test control solution for
comparison, it shall not be deeper (0.0003%).
Conductivity. Within 5 hours of preparation of the test solution, USE a
conductivity meter to measure that. The conductivity of the blank solution shall
not exceed 3.0 μS/cm (20 °C ± 1 °C). The conductivity of the test solution shall
not exceed 40.0 μS/cm. If the measurement is not performed at 20 °C ± 1 °C,
the temperature shall be corrected.
[Biological test] pyrogen* TAKE this product, ADD it into the sodium chloride
injection at irregular shape ratio, PLACE it in an autoclave at 115 °C ± 2 °C for
30 minutes. MAKE determination in accordance with the pyrogen test method
(YBB00022003-2015), the results shall comply with requirements.
Acute systemic toxicity test ** TAKE this product, ADD it into the sodium
chloride injection at irregular shape ratio, PLACE it in an autoclave at 115 °C ±
2 °C for 30 minutes. MAKE determination in accordance with the Acute
systemic toxicity test method (YBB00042003- 2015), the results shall comply
with requirements.
Hemolysis** TAKE this product, MAKE determination in accordance with
Hemolysis test method (YBB00032003-2015), the hemolysis rate shall meet
the requirements.
Attachment. Inspection rules
1.Product inspection is divided into full item inspections and partial inspections.
2.When one of the following situations occurs, the full item inspection shall be
conducted in accordance with the standard requirements.
(1) Product registration.
(2) Reproduction after major product quality accidents.
3.In the case of one of the following situations, it shall perform inspections other
than those marked with “**”.
(1) Supervise random inspection.
(2) Production resumes after production suspension.
4.After product approval and registration, if the production and use enterprises
of pharmaceutical packaging materials do not change their raw material
production areas, additives, production processes, etc., they may perform
inspections other than those items marked with “*” and “**” in accordance with
...... Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Tips & Frequently Asked QuestionsQuestion 1: How long will the true-PDF of English version of YBB 00052005-2015 be delivered?Answer: The full copy PDF of English version of YBB 00052005-2015 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice. Question 2: Can I share the purchased PDF of YBB 00052005-2015_English with my colleagues?Answer: Yes. The purchased PDF of YBB 00052005-2015_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- YBB 00052005-2015 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.
How to buy and download a true PDF of English version of YBB 00052005-2015?A step-by-step guide to download PDF of YBB 00052005-2015_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD). Step 2: Search keyword "YBB 00052005-2015". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9
|