HOME   Cart(1)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (25 Oct 2025)

TB 10505-2019 PDF English

US$490.00 · In stock · Download in 9 seconds
TB 10505-2019: Code for Design of Railway Sound Barriers
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
TB 10505-2019English490 Add to Cart 0-9 seconds. Auto-delivery Code for Design of Railway Sound Barriers Valid

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: TB 10505-2019
      

Similar standards

TB 10106   TB 10101   TB 10102   

TB 10505-2019: Code for Design of Railway Sound Barriers

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/TB10505-2019
INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA UDC J 2743-2019 Code for design of railway sound barriers Issued on. JULY 31, 2019 Implemented on. DECEMBER 01, 2019 Issued by. National Railway Administration Code for design of railway sound barriers J 2743-2019 Main drafting organizations. China Railway Fourth Survey and Design Institute Group Co., Ltd. China Railway Eryuan Engineering Group Co., Ltd. Approved by. National Railway Administration Effective date. December 1, 2019 China Railway Press Co., Ltd. 2019·Beijing

Table of Contents

Foreword... 5 1 General... 7 2 Terminology... 7 3 Basic provisions... 8 4 Acoustic design... 9 4.1 General provisions... 9 4.2 Design target value... 10 4.3 Insertion loss of sound barrier... 12 5 Structural design... 16 5.1 Materials... 16 5.2 Loads and load combinations... 21 5.3 Structural calculation... 25 5.4 Construction requirements... 26 6 Auxiliary facilities... 28 7 Interface design... 29 Explanation of wording in this code... 30 References... 31

1 General

1.0.1 In order to unify the design standards of railway sound barrier engineering, make the railway sound barrier engineering design meet the requirements of safety, reliability, green, environmental protection, advanced maturity, economical application, etc., this Code is formulated. 1.0.2 This Code is applicable to the engineering design of new and reconstructed railway sound barriers. 1.0.3 The acoustic design of the sound barrier should be determined, according to the recent traffic volume of the railway project, the type of train, the number of marshalling, the number of pairs, the design speed and other factors. 1.0.4 The sound barrier is strictly prohibited from intruding into the boundary of the railway building. It shall not affect the safety of other transportation equipment. It shall meet the inspection and maintenance requirements of itself and other railway facilities. 1.0.5 The design service life of acoustic elements of sound barrier shall not be less than 25 years. The design service life of structural components shall not be less than 50 years. The structural safety level shall not be lower than level 2. 1.0.6 The new technology, new process, new material, new equipment, which is adopted in the sound barrier project, shall comply with the relevant provisions of the current national standards. 1.0.7 In addition to this Code, the engineering design of railway sound barrier shall also comply with the relevant current national standards.

2 Terminology

2.0.1 Railway sound barrier Structures, which are used to reduce the impact of train running noise, on the acoustic environment. According to its location, it is divided into subgrade sound barrier and bridge sound barrier. 2.0.2 Post and panel sound barrier A sound barrier, which is formed by inserting sound-absorbing or sound-insulating sheet, between the uprights. 2.0.6 Sound-sensitive point Noise-sensitive buildings or areas, such as hospitals, schools, institutions, scientific research organizations, residences, nature reserves, etc. 2.0.7 Background noise The noise, which is measured at the reference point or the sound receiving point, when there is no railway noise source, within the control range of the sound barrier. 2.0.8 Insertion loss of sound barrier Under the condition that the noise source, topography, landform, ground features, meteorological conditions remain unchanged, The difference between the sound pressure level of a specific location of a sound-sensitive target of the acoustic environment, before and after the installation of the sound barrier.

3 Basic provisions

3.0.1 The sound barrier facilities shall be safe and reliable, easy to construct, conducive to repair and maintenance. 3.0.2 The setting of sound barriers is strictly prohibited to interfere with railway visual signals. 3.0.3 The location of the sound barrier shall meet the following requirements. 3.0.4 The sound barriers, which are installed in towns, scenic spots, tourist resorts, shall not only coordinate with the main project, but also coordinate with the local natural environment, architectural style, humanistic environment. 3.0.5 The sound barrier shall be naturally connected and smoothly transitioned, at the cross-section change of the road and bridge connections, the station's access section, the cable well. It shall take measures to prevent sound leakage.

4 Acoustic design

4.1 General provisions 4.1.1 The sound barrier shall be acoustically designed, according to the characteristics of railway noise source intensity and the noise control requirements of sensitive targets, in the acoustic environment. 4.1.3 The sound source equivalent height, which is used for the calculation of sound barrier insertion loss, can be determined by the following methods. 4.1.4 The length and height of the sound barrier shall be calculated and determined, according to the design target value of the insertion loss. 4.1.5 The length of the sound barrier shall include the distribution length of the acoustic environment sensitive targets, along the line, AND the additional length at both ends. The additional length can be calculated and determined according to the following formula, which should not be less than 50 m. 4.1.6 When the design target value of the insertion loss of the sound barrier is greater than 10 dB (A), the structural form of the sound barrier shall be compared, selected, demonstrated; it shall take appropriate noise control measures. 4.2 Design target value 4.2.1 It shall adopt the A sound level, for the design target value of the sound barrier. 4.2.2 The design target value of the sound barrier shall be calculated and determined, according to the following formula. 4.2.4 The relationship, between the design target value of the sound barrier and the insertion loss value of the sound barrier, shall meet the requirements of the following formula. 4.3 Insertion loss of sound barrier 4.3.1 The insertion loss of the sound barrier shall be calculated and determined, according to the following formula. 4.3.6 Where there are other barriers or obstacles, other than the proposed sound barrier, between the sound source and the sound receiving point, the sound attenuation can be determined, according to Articles 4.3.2 ~ 4.3.4 of this Code.

5 Structural design

5.1 Materials 5.1.1 In addition to the requirements of "Acoustic elements of railway sound barrier" TB/T 3122, the metallic acoustic elements of sound barriers shall also meet the following requirements. 5.1.3 In addition to complying with the requirements of "Acoustic elements of railway sound barrier" TB/T 3122, the transmission sound insulation panel of the sound barrier shall also meet the following requirements. 5.1.4 The metallic and non-metallic acoustic elements, as well as the related products of the sound barrier shall be shaped products, that meet the relevant national standards. 5.1.5 The acoustic elements of the sound barrier shall have waterproof performance; it shall have necessary drainage measures. 5.1.7 The connecting members of the sound barrier shall meet the following requirements. 5.1.8 The gravity mortar, which is used in the post and panel sound barrier, shall comply with the requirements of "Spherical bearings for railway bridges" TB/T 3320. 5.1.9 The masonry materials and mortar grades, which are used for the masonry sound barrier, shall comply with the provisions of "Code for design of masonry structures" GB 50003. 5.2 Loads and load combinations 5.2.1 The sound barrier's load shall include self-weight, natural wind load, train wind load, and other loads. Other loads shall consider seismic force, snow load, maintenance load, according to the area where the sound barrier is located AND the facade form.

6 Auxiliary facilities

6.0.1 Drainage facilities shall be provided for the subgrade sound barrier. It shall take measures to prevent sound leakage, at the drainage outlet. The drainage shall not cause erosion of the subgrade slope. 6.0.3 The sound barrier, which has safety door, shall be provided with light storage signs. It shall meet the following requirements. 6.0.4 The metal components of the sound barrier shall form an electrical connection. The grounding design shall be carried out, in accordance with the relevant provisions of "Technical code for lightning protection and earthing of railway" TB 10180. 6.0.5 The semi-enclosed and fully-enclosed sound barriers should be equipped with maintenance and anti-fall devices. Rainwater centralized collection and discharge facilities should be set up, at the locations where it crosses railways, public (roads) and other facilities.

7 Interface design

7.0.1 The subgrade design shall reserve the conditions for setting up sound barriers. The sound barrier's foundation should be designed and constructed, at the same time as the subgrade. 7.0.4 The design load of the sound barrier of the bridge shall not be greater than the design load of the sound barrier, which is reserved for the bridge. 7.0.5 When the equipment positions, such as signal reinforcement, need to be reserved inside the fully-enclosed sound barrier, the installation conditions shall be reserved. 7.0.6 For the segment where the sound barrier needs to be installed in the long term, the sound barrier foundation and installation conditions shall be reserved. Explanation of wording in this code INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA UDC J 2743-2019 Code for design of railway sound barriers Issued on. JULY 31, 2019 Implemented on. DECEMBER 01, 2019 Issued by. National Railway Administration Code for design of railway sound barriers J 2743-2019 Main drafting organizations. China Railway Fourth Survey and Design Institute Group Co., Ltd. China Railway Eryuan Engineering Group Co., Ltd. Approved by. National Railway Administration Effective date. December 1, 2019 China Railway Press Co., Ltd. 2019·Beijing

Table of Contents

Foreword... 5 1 General... 7 2 Terminology... 7 3 Basic provisions... 8 4 Acoustic design... 9 4.1 General provisions... 9 4.2 Design target value... 10 4.3 Insertion loss of sound barrier... 12 5 Structural design... 16 5.1 Materials... 16 5.2 Loads and load combinations... 21 5.3 Structural calculation... 25 5.4 Construction requirements... 26 6 Auxiliary facilities... 28 7 Interface design... 29 Explanation of wording in this code... 30 References... 31

1 General

1.0.1 In order to unify the design standards of railway sound barrier engineering, make the railway sound barrier engineering design meet the requirements of safety, reliability, green, environmental protection, advanced maturity, economical application, etc., this Code is formulated. 1.0.2 This Code is applicable to the engineering design of new and reconstructed railway sound barriers. 1.0.3 The acoustic design of the sound barrier should be determined, according to the recent traffic volume of the railway project, the type of train, the number of marshalling, the number of pairs, the design speed and other factors. 1.0.4 The sound barrier is strictly prohibited from intruding into the boundary of the railway building. It shall not affect the safety of other transportation equipment. It shall meet the inspection and maintenance requirements of itself and other railway facilities. 1.0.5 The design service life of acoustic elements of sound barrier shall not be less than 25 years. The design service life of structural components shall not be less than 50 years. The structural safety level shall not be lower than level 2. 1.0.6 The new technology, new process, new material, new equipment, which is adopted in the sound barrier project, shall comply with the relevant provisions of the current national standards. 1.0.7 In addition to this Code, the engineering design of railway sound barrier shall also comply with the relevant current national standards.

2 Terminology

2.0.1 Railway sound barrier Structures, which are used to reduce the impact of train running noise, on the acoustic environment. According to its location, it is divided into subgrade sound barrier and bridge sound barrier. 2.0.2 Post and panel sound barrier A sound barrier, which is formed by inserting sound-absorbing or sound-insulating sheet, between the uprights. 2.0.6 Sound-sensitive point Noise-sensitive buildings or areas, such as hospitals, schools, institutions, scientific research organizations, residences, nature reserves, etc. 2.0.7 Background noise The noise, which is measured at the reference point or the sound receiving point, when there is no railway noise source, within the control range of the sound barrier. 2.0.8 Insertion loss of sound barrier Under the condition that the noise source, topography, landform, ground features, meteorological conditions remain unchanged, The difference between the sound pressure level of a specific location of a sound-sensitive target of the acoustic environment, before and after the installation of the sound barrier.

3 Basic provisions

3.0.1 The sound barrier facilities shall be safe and reliable, easy to construct, conducive to repair and maintenance. 3.0.2 The setting of sound barriers is strictly prohibited to interfere with railway visual signals. 3.0.3 The location of the sound barrier shall meet the following requirements. 3.0.4 The sound barriers, which are installed in towns, scenic spots, tourist resorts, shall not only coordinate with the main project, but also coordinate with the local natural environment, architectural style, humanistic environment. 3.0.5 The sound barrier shall be naturally connected and smoothly transitioned, at the cross-section change of the road and bridge connections, the station's access section, the cable well. It shall take measures to prevent sound leakage.

4 Acoustic design

4.1 General provisions 4.1.1 The sound barrier shall be acoustically designed, according to the characteristics of railway noise source intensity and the noise control requirements of sensitive targets, in the acoustic environment. 4.1.3 The sound source equivalent height, which is used for the calculation of sound barrier insertion loss, can be determined by the following methods. 4.1.4 The length and height of the sound barrier shall be calculated and determined, according to the design target value of the insertion loss. 4.1.5 The length of the sound barrier shall include the distribution length of the acoustic environment sensitive targets, along the line, AND the additional length at both ends. The additional length can be calculated and determined according to the following formula, which should not be less than 50 m. 4.1.6 When the design target value of the insertion loss of the sound barrier is greater than 10 dB (A), the structural form of the sound barrier shall be compared, selected, demonstrated; it shall take appropriate noise control measures. 4.2 Design target value 4.2.1 It shall adopt the A sound level, for the design target value of the sound barrier. 4.2.2 The design target value of the sound barrier shall be calculated and determined, according to the following formula. 4.2.4 The relationship, between the design target value of the sound barrier and the insertion loss value of the sound barrier, shall meet the requirements of the following formula. 4.3 Insertion loss of sound barrier 4.3.1 The insertion loss of the sound barrier shall be calculated and determined, according to the following formula. 4.3.6 Where there are other barriers or obstacles, other than the proposed sound barrier, between the sound source and the sound receiving point, the sound attenuation can be determined, according to Articles 4.3.2 ~ 4.3.4 of this Code.

5 Structural design

5.1 Materials 5.1.1 In addition to the requirements of "Acoustic elements of railway sound barrier" TB/T 3122, the metallic acoustic elements of sound barriers shall also meet the following requirements. 5.1.3 In addition to complying with the requirements of "Acoustic elements of railway sound barrier" TB/T 3122, the transmission sound insulation panel of the sound barrier shall also meet the following requirements. 5.1.4 The metallic and non-metallic acoustic elements, as well as the related products of the sound barrier shall be shaped products, that meet the relevant national standards. 5.1.5 The acoustic elements of the sound barrier shall have waterproof performance; it shall have necessary drainage measures. 5.1.7 The connecting members of the sound barrier shall meet the following requirements. 5.1.8 The gravity mortar, which is used in the post and panel sound barrier, shall comply with the requirements of "Spherical bearings for railway bridges" TB/T 3320. 5.1.9 The masonry materials and mortar grades, which are used for the masonry sound barrier, shall comply with the provisions of "Code for design of masonry structures" GB 50003. 5.2 Loads and load combinations 5.2.1 The sound barrier's load shall include self-weight, natural wind load, train wind load, and other loads. Other loads shall consider seismic force, snow load, maintenance load, according to the area where the sound barrier is located AND the facade form.

6 Auxiliary facilities

6.0.1 Drainage facilities shall be provided for the subgrade sound barrier. It shall take measures to prevent sound leakage, at the drainage outlet. The drainage shall not cause erosion of the subgrade slope. 6.0.3 The sound barrier, which has safety door, shall be provided with light storage signs. It shall meet the following requirements. 6.0.4 The metal components of the sound barrier shall form an electrical connection. The grounding design shall be carried out, in accordance with the relevant provisions of "Technical code for lightning protection and earthing of railway" TB 10180. 6.0.5 The semi-enclosed and fully-enclosed sound barriers should be equipped with maintenance and anti-fall devices. Rainwater centralized collection and discharge facilities should be set up, at the locations where it crosses railways, public (roads) and other facilities.

7 Interface design

7.0.1 The subgrade design shall reserve the conditions for setting up sound barriers. The sound barrier's foundation should be designed and constructed, at the same time as the subgrade. 7.0.4 The design load of the sound barrier of the bridge shall not be greater than the design load of the sound barrier, which is reserved for the bridge. 7.0.5 When the equipment positions, such as signal reinforcement, need to be reserved inside the fully-enclosed sound barrier, the installation conditions shall be reserved. 7.0.6 For the segment where the sound barrier needs to be installed in the long term, the sound barrier foundation and installation conditions shall be reserved. Explanation of wording in this code ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of TB 10505-2019 be delivered?

Answer: The full copy PDF of English version of TB 10505-2019 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of TB 10505-2019_English with my colleagues?

Answer: Yes. The purchased PDF of TB 10505-2019_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- TB 10505-2019 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of TB 10505-2019?

A step-by-step guide to download PDF of TB 10505-2019_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "TB 10505-2019".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9