SN/T 2262-2009: Determination of aluminum, arsenic, calcium, copper, magnesium, manganese, phosphorus, lead, zincum in iron ores - Inductively coupled plasma atomic emission spectrometry
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
SN/T 2262-2009English165 Add to Cart 0-9 seconds. Auto-delivery Determination of aluminum, arsenic, calcium, copper, magnesium, manganese, phosphorus, lead, zincum in iron ores - Inductively coupled plasma atomic emission spectrometry Valid

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: SN/T 2262-2009
      

Similar standards

GB/T 6730.1   GB/T 6730.10   SN/T 5632.2   

SN/T 2262-2009: Determination of aluminum, arsenic, calcium, copper, magnesium, manganese, phosphorus, lead, zincum in iron ores - Inductively coupled plasma atomic emission spectrometry


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/SNT2262-2009
ENTRY-EXIT INSPECTION AND QUARANTINE INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA Determination of aluminum, arsenic, calcium, copper, magnesium, manganese, phosphorus, lead, zincum in iron ores - Inductively coupled plasma atomic emission spectrometry ISSUED ON: FEBRUARY 20, 2009 IMPLEMENTED ON: SEPTEMBER 01, 2000 Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China

Table of Contents

Foreword ... 3 1 Scope ... 4 2 Normative references ... 4 3 Method summary ... 5 4 Reagents ... 5 5 Instruments and apparatuses ... 5 6 Sample ... 6 7 Analysis steps ... 6 8 Results calculation and expression ... 7 9 Precision ... 7 Appendix A (Informative) Instrument working conditions ... 8 Appendix B (Informative) Element analytical line and detection-limit ... 9 Appendix C (Informative) Microwave digestion program ... 10 Determination of aluminum, arsenic, calcium, copper, magnesium, manganese, phosphorus, lead, zincum in iron ores - Inductively coupled plasma atomic emission spectrometry

1 Scope

This Standard specifies the method for the determination of aluminum, arsenic, calcium, copper, magnesium, manganese, phosphorus, lead, and zincum in iron ore by inductively coupled plasma atomic emission spectroscopy (ICP- AES). This Standard applies to the determination of aluminum, arsenic, calcium, copper, magnesium, manganese, phosphorus, lead, and zincum in iron ore. The determination range of each element is shown in Table 1. Table 1 -- Determination items and determination range Element Determination range /% Element Determination range /% Al 0.05 ~ 6.00 Mn 0.002 ~ 1.20 As 0.02 ~ 0.30 P 0.01 ~ 0.60 Ca 0.01 ~ 1.20 Pb 0.004 ~ 0.30 Cu 0.005 ~ 0.30 Zn 0.003 ~ 1.20 Mg 0.005 ~ 1.20

2 Normative references

The terms in the following documents become the terms of this Standard by reference to this Standard. For dated references, all subsequent amendments (not including errata content) or revisions do not apply to this standard. However, parties to agreements that are based on this Standard are encouraged to study whether the latest versions of these documents can be used. For undated references, the latest edition applies to this Standard. GB/T 6730.1, Iron ores - Preparation of predried test samples for chemical analysis GB/T 6682, Water for analytical laboratory use - Specification and test methods 5.2 High-pressure closed microwave digestion system: adjustable and self- controlled pressure (0 MPa ~ 4 MPa).

6 Sample

Prepare the sample according to GB/T 6730.1; dry it in an oven at (105 ± 5)°C for 2 h; place it in a desiccator to cool to room temperature.

7 Analysis steps

7.1 Weigh 0.2 g (accurate to 0.000 1 g) of sample; put it in an about 100 mL polytetrafluoroethylene digestion tank; add a small amount of water to wet; add 6 mL of hydrochloric acid (4.1), 2 mL of nitric acid (4.2), 1 mL of hydrofluoric acid (4.4); shake gently; cover the digestion tank tightly; put it into the microwave digestion furnace; close the furnace door; operate according to the set procedure (see Appendix C) according to the microwave digestion system operating procedures; after the sample is completely digested, remove for cooling; open the digestion tank; add 10 mL of boric acid solution (4.5); then, tightly close the digestion tank; put it in the microwave digestion furnace; heat for 3 min; take out for cooling; transfer all the test solution into a 100 mL volumetric flask; use water to fix-volume; shake well; after the test solution is clarified, test. Weigh two samples at the same time for parallel determination; take the average value as the result. Carry out a blank test along with the sample. 7.2 Turn on the instrument in accordance with the operating procedures; optimize the instrument's operating parameters; perform the determination after the instrument is stable. 7.3 Determine the spectral line intensity of each element in the mixed standard series solution according to the analysis conditions of the corresponding instruments; prepare the corresponding calibration working curve. The linear correlation coefficient of the curve is required to be greater than 0.999. See Table 2 for the standard solution series concentration. 7.4 Determine the spectral line intensity of each test element in the blank solution and the sample solution according to the conditions of the corresponding instrument; calculate the concentration of each test element from the calibration working curve. ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of SN/T 2262-2009 be delivered?

Answer: The full copy PDF of English version of SN/T 2262-2009 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of SN/T 2262-2009_English with my colleagues?

Answer: Yes. The purchased PDF of SN/T 2262-2009_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- SN/T 2262-2009 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of SN/T 2262-2009?

A step-by-step guide to download PDF of SN/T 2262-2009_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "SN/T 2262-2009".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9