HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (14 Jun 2025)

PDF HJ/T 56-2000 English


Search result: HJ/T 56-2000
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
HJ/T 56-2000English85 Add to Cart 0-9 seconds. Auto-delivery. Determination of sulphur dioxide from exhausted gas of stationary source - Iodine titration method  

PDF Preview: HJ/T 56-2000                   
      

HJ/T 56-2000: PDF in English (HJT 56-2000)

HJ/T 56-2000 HJ STANDARD OF STATE ENVIRONMENTAL PROTECTION ADMINISTRATION Determination of sulphur dioxide from exhausted gas of stationary source - Iodine titration method ISSUED ON. DECEMBER 07, 2000 IMPLEMENTED ON. MARCH 1, 2001 Issued by. State Environmental Protection Administration of PRC Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative references ... 4  3 Determination method-principle, determination range and determination error ... 4  4 Influential factors ... 4  5 Apparatus ... 5  6 Reagents ... 5  7 Sampling ... 7  8 Determination ... 8  9 Calculation ... 8  10 Calculation of sulfur dioxide emission rate ... 8  Foreword This Standard specifies the iodine titration method to determine the concentration of sulphur dioxide from exhausted gas of stationary source as well as its total emission. During the formulating, this Standard referred to the national standard. GB/T 16157- 1996 “The determination of particulates and sampling methods of gaseous pollutants emitted from exhaust gas of stationary source” and parts of “Air and waste gas monitoring analysis method” issued by State Environmental Protection Administration in 1990. It also referred to relevant sampler’s technical indicators and domestic-foreign enterprise standards. This Standard was proposed by Department of Science, Technology and Standards of State Environmental Protection Administration. This Standard was drafted by China National Environmental Monitoring Center. This Standard shall be interpreted by State Environmental Protection Administration. Determination of sulphur dioxide from exhausted gas of stationary source - Iodine titration method 1 Scope This Standard specifies the iodine titration method to determine the concentration of sulphur dioxide from exhausted gas of stationary source as well as the determination of sulfur dioxide emission rate. 2 Normative references The following standard contains the provisions which, through reference in this Standard, constitute the provisions of this Standard. It has the same effect as this Standard. GB/T 16157-1996 The determination of particulates and sampling methods of gaseous pollutants emitted from exhaust gas of stationary source 3 Determination method-principle, determination range and determination error Sulfur dioxide from exhausted gas is absorbed by the mixed solution of ammonium sulfamate. Use iodine standard solution to titrate. Calculate the sulfur dioxide concentration according to the titration. Reactions are shown as follows. Determination range. 100 ~ 6000 mg/m3; within the determination range, the batch error of the method shall not be greater than ± 6%. 4 Influential factors 4.1 When boiler fuel is burning under normal conditions, the content of reducing substances such as H2S in the exhausted gas is very little; its influence to the determination is negligible. 4.2 Ammonium sulfamate in absorption solution can eliminate the influence of carbon 7.3 Sampling frequency Under same working conditions, it shall determine three times in a row; take the average value as determination result. 8 Determination After sampling, it shall titrate the sample as soon as possible. The sample shall not be placed for more than 1h. Move all samples in two absorption bottles into the iodine bottle. Use a small amount of absorption solution (6.1) to respectively wash the absorption bottle twice. Move the washing solution into the iodine bottle as well. Shake well. When adding 50 ml of 2 g/L starch solution (6.3), use 0.010 mol/L iodine standard solution (6.8) to titrate to blue. Record the consumption V (ml). Separately, take the absorption solution (6.1) of same volume. Conduct blank titration in the same method. Record the consumption V0 (ml). If the sulfur dioxide concentration of the gas is high, it shall take part of absorption solution to titrate. At this time, the result calculated according the equation listed in Clause 9 shall be divided by the ratio of partial absorption solution accounting for total absorption solution. 9 Calculation Where, c’ - sulfur dioxide concentration of dry gas under standard conditions (mg/m3); c(1/2 I2) - concentration of iodine stock solution (mol/L); Vnd - sampling volume of dry gas under standard conditions (L); 32.0 - the mass (g) of sulfur dioxide (1/2 SO2) that is equal to 1 L of 1 mol/L iodine standard solution (1/2 I2). 10 Calculation of sulfur dioxide emission rate 10.1 Determination and calculation of exhausted gas flow According to provisions in 7.1 ~ 7.5 of GB/T 16157-1996, measure the exhaust flow rate. According to provisions in 7.6, calculate dry exhaust gas flow Qsn (m3/h) under standard conditions. Where, Qsn - dry exhaust gas flow under standard conditions. 10.2 Calculation of sulfur dioxide emission rate 10.2.1 When sulfur dioxide concentration is represented in ppm (V/V), its concentration c can be converted to sulfur dioxide concentration of dry gas under standard conditions, according to the following equation. Where, c’ - sulfur dioxide concentration of dry gas under standard conditions (mg/m3). 10.2.2 Calculation of sulfur dioxide emission rate G ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.