GB/T 38301-2019: Determination of Limiting Oxygen Concentration (LOC) of Flammable Gases and Vapors
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
GB/T 38301-2019English210 Add to Cart 0-9 seconds. Auto-delivery Determination of Limiting Oxygen Concentration (LOC) of Flammable Gases and Vapors Valid

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: GB/T 38301-2019
      

Similar standards

GB/T 40237   GB/T 16840.2   GB/T 20284   GB/T 41382   

GB/T 38301-2019: Determination of Limiting Oxygen Concentration (LOC) of Flammable Gases and Vapors


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT38301-2019
GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 13.220.01 C 80 Determination of Limiting Oxygen Concentration (LOC) of Flammable Gases and Vapors ISSUED ON: DECEMBER 10, 2019 IMPLEMENTED ON: APRIL 01, 2020 Issued by: State Administration for Market Regulation; Standardization Administration of PRC.

Table of Contents

Foreword ... 3 Introduction ... 4 1 Scope ... 5 2 Normative References ... 5 3 Terms and Definitions ... 5 4 Reagents and Materials ... 8 5 Test Device ... 8 6 Test Methods ... 8 7 Calibration of Test Device ... 12 8 Test Report ... 12 Appendix A (Informative) Example of LAC Determination ... 13 Bibliography ... 15 Determination of Limiting Oxygen Concentration (LOC) of Flammable Gases and Vapors Warning - After igniting the flammable gas, inert gas and air mixture in accordance with the method specified in this Standard, even if flame propagation is not formed, it cannot be completely assumed that the mixture shall not explode.

1 Scope

This Standard specifies the method for determining the limiting oxygen concentration of flammable gas (vapor). This Standard is applicable to the determination of the limiting oxygen concentration of flammable gas (vapor) under normal pressure.

2 Normative References

The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) is applicable to this document. GB/T 803 Determination of Explosion Indices of Combustible Gases in Air GB/T 5907.1 Fire Protection Vocabulary - Part 1: General Terms GB/T 5907.2 Fire Protection Vocabulary - Part 2: Fire Prevention GB/T 12474 Method of Test for Explosion Limits of Combustible Gases in Air GB/T 16425 Determination for Minimum Explosive Concentration of Dust Cloud GB/T 21844 Standard Test Method for Concentration Limits of Flammability of Chemicals (Vapors and Gases)

3 Terms and Definitions

For the purpose of this document, the terms and definitions given in GB/T 5907.1, GB/T

4 Reagents and Materials

The air used in the test shall be purified; if it is synthetic air, it shall be indicated in the report. The purity of the inert gas used in the test shall be no less than 99.8% (volume fraction). If it is a mixed inert gas, it shall be stated in the report. The flammable gas (vapor) determined in the test may be a single substance, a mixture or process-sampling (known or unknown composition); thereof, the purity of the single substance and the single substance in the mixture shall be no less than 99.8% (volume fraction). If a large amount of gas volatilizes in the liquid mixture, and the gas and liquid phase components change with time, liquid phase substances shall be used for testing and sampling.

5 Test Device

The test device of limiting oxygen concentration adopts tubular device (T) or ball device (B, including cylindrical). The tubular device shall meet the requirements of test devices specified in GB/T12474. The ball device may be a 20L spherical stainless-steel explosion tank, a 1m3 cylindrical container, a 5L or 12L short-ring-necked bottle, which shall meet the requirements of test devices specified in GB/T 16425, GB/T 803, and GB/T 21844, respectively.

6 Test Methods

6.1 Test principle Use tubular device or ball device to test and determine the explosion area of flammable gas (vapor), air and inert gas. By increasing the volume fraction of inert gas, test and determine the limiting air concentration, LAC, of flammable gas (vapor); and then further calculate and determine the limiting oxygen concentration, LOC, of the flammable gas to be tested. 6.2 Test procedures 6.2.1 General requirements According to the following test procedures, repeat the test four times to determine the limiting air concentration, LAC, of the flammable gas to be tested. After the gas is equipped, it shall be stirred evenly: --- Step 1: Determine the lower explosion limit, LEL, and upper explosion limit, UEL, concentration LOC ± 0.2% [calculated value by Formula (1)]. The concentration of oxygen analysis equipment shall be calibrated within the range of 0%~21% volume fraction. When measuring by the tubular device specified in GB/T 12474, the oxygen concentration shall be measured at the outlet of the container before starting ignition. When measuring by the ball device specified in GB/T 16425 and GB/T 803, the mixture shall be measured in the ball to be evenly mixed and sampled for oxygen concentration measurement before ignition.

7 Calibration of Test Device

The test device is calibrated according to the requirements of GB/T 12474, GB/T 16425, and GB/T 803. The installed device is calibrated by ethylene with a purity of no less than 99.9% (the volume fraction of the lower explosion limit of ethylene is 2.7%, and the volume fraction of the upper explosion limit is 36%) before the formal measurement. If the measured result meets the following requirements, that is to say, the device is operating normally: a) The error of the repeatability test results measured by the same laboratory shall not exceed 5%; b) The error of the repeatability test results measured by the different laboratories shall not exceed 10%.

8 Test Report

The test report shall include the following contents: a) The type and purity of the flammable gas (vapor) to be tested; b) The type and purity of the inert gas; and the composition, purity and source, etc. of the air; c) Environmental conditions during the test; d) Test device, tubular device or ball device, test device container shape, volume and ignition method, etc.; e) The explosion limit is determined according to relevant standards or by using explosion area diagrams; f) The Limiting oxygen concentration, LAC [Translator Note: here it should be LOC]; g) If the test operation deviates from this Standard, it shall be explained; h) Test date. ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of GB/T 38301-2019 be delivered?

Answer: The full copy PDF of English version of GB/T 38301-2019 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of GB/T 38301-2019_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 38301-2019_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- GB/T 38301-2019 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of GB/T 38301-2019?

A step-by-step guide to download PDF of GB/T 38301-2019_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "GB/T 38301-2019".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9