HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (8 Jun 2025)

PDF GB/T 2099.3-2022 English (GB/T 2099.3-2015: Older version)


Search result: GB/T 2099.3-2022 (GB/T 2099.3-2015 Older version)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 2099.3-2022English590 Add to Cart 0-9 seconds. Auto-delivery. Plugs and socket-outlets for household and similar purposes - Part 2-5: Particular requirements for adaptors Valid
GB/T 2099.3-2015English165 Add to Cart 0-9 seconds. Auto-delivery. Plugs and socket-outlets for household and similar purposes -- Part 2-5: Particular requirements for adaptors Obsolete
GB 2099.3-2015English85 Add to Cart 0-9 seconds. Auto-delivery. [GB/T 2099.3-2015] Plugs and socket-outlets for household and similar purposes -- Part 2-5: Particular requirements for adaptors Obsolete
GB 2099.3-2008English105 Add to Cart 0-9 seconds. Auto-delivery. Plugs and socket-outlets for household and similar purposes -- Part 2: particular requirements for adaptors Obsolete
GB 2099.3-1997English599 Add to Cart 3 days Plugs and socket-outlets for household and similar purposes--Part 2: Particular requirement for adaptors Obsolete

PDF Preview: GB/T 2099.3-2022                   PDF Preview: GB/T 2099.3-2015
            

GB/T 2099.3-2022: PDF in English (GBT 2099.3-2022)

GB/T 2099.3-2022 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 29.120.30 CCS K 30 Replacing GB/T 2099.3-2015 Plugs and Socket-outlets for Household and Similar Purposes - Part 2-5.Particular Requirements for Adaptors (IEC 60884-2-5.2017, MOD) ISSUED ON. OCTOBER 12, 2022 IMPLEMENTED ON. MAY 1, 2023 Issued by. State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of Contents Foreword... 4 Introduction... 10 1 Scope... 12 2 Normative References... 12 3 Terms and Definitions... 13 4 General Requirements... 15 5 General Description Regarding Tests... 16 6 Ratings... 16 7 Classification... 16 8 Markings... 16 9 Dimension Inspection... 18 10 Protection against Electric Shock... 18 11 Grounding Measures... 19 12 Terminal and Termination... 19 13 Construction of Fixed Socket-outlets... 20 14 Construction of Plugs and Movable Socket-outlets... 20 15 Interlocking Socket-outlets... 23 16 Aging Resistance, Protection Provided by Enclosures and Moisture-proof... 24 17 Insulation Resistance and Electrical Strength... 24 18 Operation of Grounding Contacts... 25 19 Temperature Rise... 25 20 Breaking Capacity... 28 21 Normal Operation... 29 22 Force Required to Pull out the Plug... 30 23 Flexible Cables and Their Connection... 33 24 Mechanical Strength... 35 25 Heat Resistance... 36 26 Screws, Current-carrying Components and Their Connections... 36 27 Creepage Distances, Clearances and Distances through Sealing Compound... 36 28 Resistance of Insulating Materials to Abnormal Heat, Fire and Tracking... 37 29 Resistance to Rusting... 38 Plugs and Socket-outlets for Household and Similar Purposes - Part 2-5.Particular Requirements for Adaptors 1 Scope Chapter 1 of GB/T 2099.1-2021 is replaced by. This document stipulates the technical requirements for the ratings, markings, protection against electric shock, construction, electrical properties and mechanical properties, etc. of adaptors. This document is applicable to adaptors for indoor or outdoor use, household and similar purposes, only for alternating current, and with a rated voltage above 50 V but not more than 440 V, a rated current not exceeding 32 A, with or without a grounding contact. This document also applies to travel adaptors (see Appendix AA). For travel adaptors, the scope is limited to adaptors with a rated voltage above 50 V but not more than 250 V, and a rated current not exceeding 20 A. Travel adaptors that simultaneously connect two or more plugs are beyond the scope of this document. This document includes the requirements for adaptors with additional functionality, but it does not include requirements for the additional functionality itself. NOTE 1.additional functionality includes electronic power supply, dimmer, timer, protection device and infrared switch, etc. This document does not apply to adaptors equipped with appliance couplers that comply with the provisions of GB/T 17465 (all parts). Adaptors that comply with the requirements of this document are suitable for normal use where the ambient temperature usually does not exceed +40 C, but the average ambient temperature within a 24 h period does not exceed +35 C, and the lower limit of the ambient air temperature is 5 C. NOTE 2.tests at temperatures below the normal range are being considered. 2 Normative References The contents of the following documents constitute indispensable clauses of this document through the normative references in the text. In terms of references with a specified date, only versions with a specified date are applicable to this document. In terms of references without a specified date, the latest version (including all the modifications) is applicable to this document. 3.106 travel adaptor A mobile electrical accessory intended for temporary use, allowing one or multiple types of plugs from different national systems to be connected to socket-outlets not designed for plug- in of these plugs. NOTE 1.travel adaptor does not have to be an integral unit, it may integrate additional functionality. NOTE 2.examples of the national systems are listed in IEC TR 60083. 3.107 travel adaptor with movable pins A travel adaptor with a plug pin that can slide in and out, swivel or fold in any direction, i.e., the pin is not permanently fixed, but there are measures of locking it in its normal use position. 3.108 intermediate adaptor An adaptor that allows one or multiple plugs to be connected to a socket-outlet through control devices, such as. dimmer switches and photoelectric switches, etc. The control devices are connected to the adaptors through an external flexible cable. 3.109 rewireable intermediate adaptor An intermediate adaptor with a replaceable external flexible cable construction. 3.110 non-rewireable intermediate adaptor An intermediate adaptor that is connected with the external flexible cable and assembled into an integral unit by the manufacturer. NOTE. see 14.1. 3.111 adaptor with cable outlet A rewireable or non-rewireable adaptor with a construction for connecting the external flexible cable through a flexible cable outlet. 3.112 rated power The power value specified by the manufacturer for an electrical accessory. 4 General Requirements Chapter 4 of GB/T 2099.1-2021 is applicable. The travel adaptors are not allowed to charge electric vehicles and electric bicycles. 5 General Description Regarding Tests Chapter 5 of GB/T 2099.1-2021 shall be applicable after adding the following content. For the purpose of this test, unless otherwise specified, the term “adaptor” includes fused adaptor, polarized adaptor, single-way adaptor, multi-way adaptor, intermediate adaptor and adaptor with cable outlet. It is also referred to as travel adaptor in Appendix AA. 6 Ratings Chapter 6 of GB/T 2099.1-2021 shall be applicable after adding the following content. 6.101 The rated voltage of the adaptors shall not be lower than the nominal voltage of the supply system, to which, it can be connected through a socket-outlet. NOTE. the nominal voltage is defined in GB/T 156. 6.102 The rated current of the adaptors shall take the minimum value of the following currents. ---the rated current of the plug part; or ---the arithmetic sum of the maximum rated currents of all plugs that can be simultaneously plugged into the adaptor; or ---the rated current of a built-in overcurrent protection device (if any). 6.103 When given, the rated power of the adaptors shall be calculated by multiplying the rated current (specified in 6.102) by the rated voltage (specified in 6.101) at a power factor of 1. Whether it satisfies the requirements of 6.101 ~ 6.103 can be checked by observing the signs. 7 Classification Chapter 7 of GB/T 2099.1-2021 is applicable. 8 Markings Chapter 8 of GB/T 2099.1-2021 shall be applicable after the following modifications. 8.1 The content of the first dash is modified into. ---rated current (A) or rated power (W), or both; Add the following content at the end of the sub-clause. plug of the same system with the live bushing of the adaptor, or the pin of the adaptors with the live bushing of a socket-outlet of the same system. 10.4 Paragraph 1 is modified into the following content. The external components of the plug shall be made of insulating materials; but with exceptions of assembly screws, as well as current-carrying and grounding pins, grounding strips, metal rings surrounding the pins, and easily accessible metal parts that comply with the requirements of 10.2.1 or 10.2.2 in GB/T 2099.1-2021. 10.5 Paragraph 1 is modified into the following content. The socket-outlet part of the adaptors with a shutter shall also be structurally designed to ensure that the probes shown in Figure 9 and Figure 10 of GB/T 2099.1-2021 cannot touch the live parts without being mated with the plug. For the combination jack of the adaptors with a shutter, when one plug is plugged-in and the remaining jacks are not plugged-in, the probes shown in Figure 9 and Figure 10 of GB/T 2099.1-2021 shall not touch the live parts. Add the following content. 10.101 When the adaptors is completely mated with the socket-outlet, the removal of the fuse and / or fuse holder shall not cause the live parts to become accessible. Compliance is checked by observation and, in case of doubt, when the fuse and / or fuse support is not in the normal use position and the adaptors is completely mated with the socket-outlet, by using the test tool 13 of GB/T 16842-2016 to apply a force not exceeding 5 N. The test tool shall not touch the live parts. 11 Grounding Measures Chapter 11 of GB/T 2099.1-2021 is applicable. 12 Terminal and Termination Chapter 12 of GB/T 2099.1-2021 shall be applicable after the following modifications. 12.1.2 Replaced by. Rewireable adaptors and rewireable intermediate adaptors with cable outlets shall be equipped with the screw-clamp type terminals. 14.23.101 The adaptors shall be able to withstand lateral stresses that may be exerted by devices inserted into them. Compliance is checked by the following test through the device shown in Figure 13 of GB/T 2099.1-2021. Firstly, the specimen is mounted on a vertical surface, so that the plane passing through the live bushing is in a horizontal direction. The test surface shall be in a vertical position and parallel to the vertical mounting surface. Then, completely insert the device and apply a force of 5 N in the vertical downward direction. After 1 min, remove the device and swivel the adaptor by 90 on the mounting surface. Test four times and swivel the mating surface by 90 each time. During the test, the device shall not be completely disengaged. The test shall be repeated for each socket-outlet part of the adaptor. After the test, the adaptor shall not be damaged within the meaning of this document and shall, in particular, comply with the requirements of Chapter 22. 14.24 Modified into. The shape of the adaptors and / or the material they are made of shall make it easy to pull out the adaptors from the corresponding socket-outlets. In addition, the gripping surface shall be designed so that the adaptors can be pulled out without pulling on the flexible cable. Compliance is checked by observation. In case of doubt, check by test. NOTE. an example of the test is provided in Appendix C, and the “adaptors” are used instead of the “plugs”. 14.25 This clause of GB/T 2099.1-2021 does not apply. Add the following content. 14.101 If any of the socket-outlets in the socket-outlet part of the adaptors has a grounding bushing or contact, then, the plug part of the adaptors shall also have a grounding pin or contact. Adaptors connecting socket-outlets with grounding contacts to plugs without grounding contacts for Category-0 equipment are not allowed. Compliance is checked by observation and the test of 11.5. 14.102 The adaptors used in polarized socket-outlets shall be designed so that their internal connections shall ensure that the plug pins, and bushings and terminals (if any) of the socket- outlets maintain the same polarity for the input and output parts of the adaptors. Compliance is checked by observation and, if necessary, an electrical continuity test. 14.103 If the insulation of the external flexible cable does not satisfy the requirements of the corresponding national standards, and the electrical strength test between the flexible cable and the metal foil wrapped outside the insulation layer specified in 17.3 of GB/T 2099.1-2021 does not comply with the requirements, then, the flexible cable shall be considered as a bare conductor. 14.104 The body of the fused adaptors shall be equipped with suitable fuse links that comply with the relevant requirements of GB/T 13539.3, GB/T 9364.2 or GB/T 9364.3. The fuse link shall be connected between the adaptor plug pin and its corresponding socket- outlet bushing. In polar systems, the fuse link shall be installed between the phase line plug pin and the corresponding phase line socket-outlet bushing. The fuse links shall not be installed in grounded circuits. The adaptors shall be designed so that when assembled, they will not leave the fuse links in a poor contact condition. Compliance is checked by observation. 14.105 The adaptors shall not have an enclosure shaped or decorated to resemble a toy. NOTE. examples of such enclosures are those representing animals, people, characters or scale models. Spraying is not included. Compliance is checked by observation. 14.106 The socket-outlet part of the adaptors shall not allow plugs with a rated current higher than the rated current of the plug part on the adaptors to be plugged in, unless the adaptors are equipped with an overcurrent protection device with a rated current less than or equal to the rated current of the plug part on the adaptors. Compliance is checked by observation. 14.107 Chinese socket-outlets used on the adaptors shall adopt shutters or other protective measures to prevent electric shock. NOTE 1.other protective measures, such as. electronic, mechanical and interlocking, etc. Other protective measures are indicated on the relevant product instructions. NOTE 2.examples of the adaptors are shown in Appendix BB. 15 Interlocking Socket-outlets Chapter 15 of GB/T 2099.1-2021 shall be applicable after the following modifications. assembly screws, the measurement shall be conducted with the plug mated. b) When the plug is in the mated condition, the measurement shall be conducted successively between each pole and all other poles, which are connected together to a metal foil in contact with the outer surface of external accessible parts made of insulating materials, including external assembly screws. c) For the adaptors with cable outlet and the rewireable intermediate adaptors, the measurement shall be conducted between any metal parts of the flexible cord fixing part, including the clamping screws, and the grounding pins or grounding terminals (if any). d) For the adaptors with cable outlet and the rewireable intermediate adaptors, the measurement shall be conducted between any metal parts of the flexible cord fixing part and a metal rod inserted as thick as the maximum diameter (Table 17 in GB/T 2099.1-2021) of a flexible cable (or cord) in its normal position. For this test, the assembled elements connected in parallel with the live bushing shall be disconnected, and, if necessary, the specimens shall be prepared by the manufacturer. While using a metal foil to wrap the outer surface of the insulating material component or placing the metal foil in contact with the inner surface of the insulating material component, use an unobvious force and the test tool 11 of GB/T 16842-2016 to press the metal foil into the hole or groove. 17.2.3 This clause of GB/T 2099.1-2021 does not apply. 18 Operation of Grounding Contacts Chapter 18 of GB/T 2099.1-2021 is applicable. 19 Temperature Rise Chapter 19 of GB/T 2099.1-2021 is replaced by. The construction of the adaptors shall comply with the following temperature rise test requirements. All adaptors shall be tested in accordance with 19.101.The adaptors with assembled elements shall be additionally tested in accordance with 19.102. For the test of 19.101, if necessary, the specimens shall be prepared by the manufacturer. 19.101 The adaptors shall be tested in an unventilated environment at the center of the surface of a wooden block, which is at least 20 mm thick, 500 mm wide and 500 mm high. The socket-outlet part of the adaptors shall be tested with a test plug, whose pins shall be of brass and shall have the specified minimum dimensions. Clamping elements complying with the dimensional requirements in Figure 44 of GB/T 2099.1- 2021 shall be installed on each live pin and grounding pin (if any) of the plug part of the adaptors. Each clamping element shall be equipped with a thermocouple, which may be mounted on a pin together with the clamping element or permanently fixed in the point area as shown in Figure 44 of GB/T 2099.1-2021. If due to the design of the plug, it is not possible to use the clamping elements of Figure 44 of GB/T 2099.1-2021, for the purpose of carrying out this test, the clamping device may be modified. Under this circumstance, the diameter of the screw, the threaded hole and the total volume of the modified clamping elements shall be the same as Figure 44 of GB/T 2099.1-2021. Then, place the screw approximately at the center of the exposed pin part and use a torque of 0.8 N  m to tighten it. Next, pass the AC power specified below for 60൅50 min. The adaptors with side grounding contacts or elastic grounding contacts in the plug part shall be tested with a fixed socket-outlet that complies with the relevant national standards and has as average characteristics as possible, but the size of the grounding pin (if any) shall be minimum. Under the latter circumstance, plug the adaptor under test into the fixed socket-outlet and pass the AC power specified below for 60൅50 min. The adaptors with assembled elements shall be tested in accordance with the following method. ---assembled elements connected in series to the live bushings shall be short-circuited; ---assembled elements connected in parallel to the live bushings shall be disconnected. The non-rewireable adaptors and the non-rewireable intermediate adaptors with cable outlet shall be tested with the supplied cables. The rewireable adaptors and the rewireable intermediate adaptors with cable outlet shall be connected to polyvinyl chloride insulated flexible wires with a nominal cross-sectional area as shown in Table 101. The adaptors with cable outlet shall be tested in accordance with the requirements for multi- way adaptors, considering the flexible cable outlet as the socket-outlet part of the adaptors. In this clause, In is the rated current of the adaptors. 2) For the multi-way adaptors with overcurrent protection devices, the total test current is the agreed tripping current / fusing current 1 hour after the overcurrent protection devices are installed, but it cannot be higher than the value of the test value in b) 1). For the non-rewireable adaptors, special care shall be taken when approaching the termination of the adaptors to minimize the impact on the construction / design / performance of the adaptors. For adaptors with three or more poles, during the test, the current must pass through the phase contacts. In addition, the current must pass through the neutral contacts and the nearby phase contacts (if any), and the current must also pass through the grounding contacts and the closest phase contact (if any). When conducting this test, the grounding contacts, regardless of their number, are considered to be one pole. Use thermocouples to determine the temperature rise of terminals, terminations and clamping elements that comply with Figure 44 of GB/T 2099.1-2021, and the temperature rise shall not exceed 45 K. When carrying out the test of 25.4 in GB/T 2099.1-2021, the temperature rise of external parts of insulating materials that are not necessary to maintain current-carrying components and grounding circuit components in their normal positions shall also be determined, even if they are in contact with the current-carrying components and grounding circuit components. 19.102 In addition to the test of 19.101, the adaptors with assembled elements shall also be tested in accordance with the test method described in a) of 19.101, provided that the assembled elements are not short-circuited or disconnected, and the test current is the minimum of the following two. the rated current of the overcurrent protection devices (if any) and the rated current of the corresponding plug that can be plugged into the adaptors. During the test, except for the overcurrent protection devices, the assembled elements shall operate under the most unfavorable conditions of power loss. When the assembled elements must operate at the rated voltage, the test voltage shall be their rated voltage. During the test, in addition to the temperature rise of terminals, terminations and clamping elements that comply with Figure 44 of GB/T 2099.1-2021, the maximum temperature rise of the accessible metal parts shall be measured and it shall not exceed 30 K; the temperature rise of the accessible non-metallic components shall not exceed 40 K. For the non-rewireable adaptors, special care shall be taken when approaching the termination of the adaptors to minimize the impact on the construction / design / performance of the adaptors. 20 Breaking Capacity Chapter 20 of GB/T 2099.1-2021 shall be applicable after the following modifications. Paragraph 2 is modified into the following content. Compliance is checked by using the test equipment shown in Figure 16 of GB/T 2099.1-2021 to test the socket-outlet part of the adaptors and the plug part with non-solid pins. Paragraph 4 is modified into the following content. The socket-outlet part of the adaptors shall be tested with a test plug. The pins of the test plug shall be made of brass, and if applicable, shall have an insulating sheath. The pins of the test plug shall have a maximum specified size, with a tolerance of 00.06 mm, and the space between the pins is the nominal distance, with a tolerance of ൅ 0.050 mm. However, as far as insulating sheaths are concerned, it is sufficient as long as their dimensions are within the tolerance range provided in the relevant standards. Paragraph 8 is modified into the following content. Plug (in) the plug part and pull (out) from the socket-outlet for 50 times (100 strokes). The plug- in and pull-out rate is. ---For adaptors with a rated current not greater than 16 A and a rated voltage not greater than 250 V, 30 strokes per minute; ---For other adaptors, 15 strokes per minute. Paragraph 9 is modified into the following content. The test voltage is 1.1 times the rated voltage of the plug that can be plugged into the socket- outlet part of the adaptors. The test current is 1.25 times the rated current of the plug that can be plugged into the socket-outlet part of the adaptors. Add before the second to last paragraph. Each socket-outlet part and plug part of the adaptors shall be independently tested. The adaptors with assembled elements shall be tested in accordance with the following method. ---assembled elements connected in series to the live bushings shall be short-circuited; ---assembled elements connected in parallel to the live bushings shall be disconnected. 21 Normal Operation Chapter 21 of GB/T 2099.1-2021 shall be applicable after the following modifications. Paragraph 2 is modified into. Compliance is checked by using the test equipment shown in Figure 16 of GB/T 2099.1-2021 to test the socket-outlet part of the adaptors and the plug part with elastic grounding bushings ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.