HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (11 Oct 2025)

GB 50222-2017 PDF English

US$115.00 · In stock · Download in 9 seconds
GB 50222-2017: Code for fire prevention in design of interior decoration of buildings
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid

GB 50222: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
GB 50222-2017English115 Add to Cart 0-9 seconds. Auto-delivery Code for fire prevention in design of interior decoration of buildings Valid
GB 50222-1995English85 Add to Cart 0-9 seconds. Auto-delivery [GB 50222-2001 Edition] Code for fire prevention in design of interior decoration of buildings Obsolete

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: GB 50222-2017
      

Similar standards

GB 50261   GB 50116   GB 50281   GB 55036   

GB 50222-2017: Code for fire prevention in design of interior decoration of buildings

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB50222-2017
GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA UDC P GB 50022-2017 Code for fire prevention in design of interior decoration of buildings Issued on. JULY 31, 2017 Implemented on. APRIL 01, 2018 Issued by. Ministry of Housing and Urban-Rural Development of PRC; General Administration of Quality Supervision Inspection and Quarantine of PRC. NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA Code for fire prevention in design of interior decoration of buildings Main drafting department. Ministry of Public Security of PRC Approving department. Ministry of Housing and Urban-Rural Development of PRC Date of implementation. April 1, 2018 2017 Beijing Announcement of Ministry of Housing and Urban-Rural Development No.1632

Table of Contents

Foreword... 5 1 General provisions... 7 2 Terms... 8 3 Types and classification decoration materials... 9 4 Typical places... 10 5 Civil buildings... 13 5.1 Single-storey and multi-storey civil buildings... 13 5.2 High-rise civil buildings... 15 5.3 Underground civil buildings... 17 6 Factory buildings and warehouses... 19 Explanation of wording in this standard... 21 List of quoted standards... 22

1 General provisions

1.0.1 This Code is formulated to standardize the design of interior decoration of buildings, reduce fire hazards, and protect personal and property safety. 1.0.2 This Code is applicable to the design of fire prevention in interior decoration of industrial and civil buildings. It is not applicable to the design of fire prevention in interior decoration of ancient buildings and wooden structures. 1.0.3 The design of interior decoration for the building shall actively adopt non- combustible materials and flame-retardant materials, avoid the use of materials that generate a large amount of smoke or poisonous gases during combustion, so that it is safe and applicable, advanced in technology and economical. 1.0.4 The design in fire prevention of interior decoration of the building shall comply with the provisions of the relevant current national standards in addition to the provisions of this Code.

2 Terms

2.0.1 Interior decoration of buildings Such activities as decoration, protection, installation of fixed facility which are performed for the interior space of building for the purposes to meet the functional needs. 2.0.3 Partition A fixed vertical vertical partition, which does not reach to the roof, inside the building. 2.0.4 Fixed furniture Furniture that is fixed to the building structure or that is not easy to change position, such as the closet, wall cabinets, display stands, large shelves and so on inside the building.

3 Types and classification decoration materials

3.0.1 Decoration materials may, according to the location of use and the function, be divided into seven categories. decoration materials for ceiling, decoration materials for wall, decoration materials for floor, decoration materials for partition, fixed furniture, decorative fabrics, other decoration materials. 3.0.2 The decoration materials shall, according to their combustion performance, be divided into four grades. They shall also comply with the provisions of Table 3.0.2 of this Code. 3.0.4 The gypsum plaster board and mineral-wool acoustic board which have a combustion performance of grade B1 and are installed on the metal joist can be used as the grade A decoration materials. 3.0.5 For the paper and cloth wallpaper which has a mass per unit area of less than 300 g/m2, when it is directly pasted onto the grade A substrate, it can be used as the grade B1 decoration material.

4 Typical places

4.0.1 Interior decoration of buildings shall not arbitrarily reduce, alter, remove, obstruct the fire-fighting facilities, evacuation signs, safety exits, evacuation exits, evacuation walkways, fire compartments, smoke compartments, etc. 4.0.2 The fire hydrant box’s door inside the building shall not be sheltered by the decoration. The color of the decoration material around the fire hydrant box’s door shall be clearly different from the color of the fire hydrant box’s door; or otherwise it shall provide the illuminating sign on the surface of the fire hydrant box’s door. 4.0.4 For the horizontal evacuation walkways and the safe exit’s halls of the above-ground buildings, the ceiling shall use the grade A decoration materials; the other parts shall use the decoration materials which are not lower than grade B1. 4.0.5 The ceiling, wall, and floor of the evacuation stairwell and the front room shall use the grade A decoration materials. 4.0.8 The combustion performance grade of the interior decoration materials of the windowless room shall be increased by one grade in addition to the grade A, based on the provisions of Table 5.1.1, Table 5.2.1, Table 5.3.1, Table 6.0.1, Table 6.0.5. 4.0.12 For the restaurant and scientific research laboratories that often use open flame appliances, the combustion performance grade of the decoration materials shall be increased by one grade, based on the provisions in Table 5.1.1, Table 5.2.1, Table 5.3.1, Table 6.0.1, Table 6.0.5. 4.0.13 For the warehouse or storage room in the civil building, all the interior decoration shall comply with the provisions for the corresponding locations, the decoration materials shall be not lower than grade B1. 4.0.19 The interior of the building should not be equipped with wall hangings, fabrics, etc., which are made of grade B3 decoration materials. When it is necessary to set up, it shall not be close to electrical lines, fire sources or heat sources; or otherwise it shall take isolation measures. 4.0.20 For the places which are not specified in this Code, the internal decoration shall be carried out in accordance with the relevant provisions of this Code.

5 Civil buildings

5.1 Single-storey and multi-storey civil buildings 5.1.1 The combustion performance grade of the decoration materials in various parts of single-storey and multi-storey civil buildings shall not be lower than the provisions of Table 5.1.1 of this Code. 5.2 High-rise civil buildings 5.2.1 The combustion performance grade of the decoration materials of various parts inside the high-rise civil building shall not be lower than the provisions of Table 5.2.1 of this Code. 5.3 Underground civil buildings 5.3.1 The combustion performance grade of the decoration materials of various parts inside the underground civil building shall not be lower than the provisions of Table 5.3.1 of this Code. 5.3.2 Except for the places as specified in clause 4 of this Code and the locations as specified in item No.6 ~ 8 of Table 5.3.1 of this Code, for the above- ground part of the underground civil building which is constructed separately, the combustion performance grade of the interior decoration materials for the foyer, lounge, office, etc.

6 Factory buildings and warehouses

6.0.1 The combustion performance grade of the decoration materials of various parts inside the factory building shall not be lower than the provisions of Table 6.0.1 of this Code. 6.0.3 When the floor of the factory building is an elevated floor, the floor shall use the decoration materials of not lower than grade B1. 6.0.4 For the supporting rooms for office, research and development, catering, etc., which are attached inside industrial buildings, when using the fire separation and evacuation facilities as specified in the current national standard “Code of design on building fire protection and prevention” GB 50016, the combustion performance grade of the interior decoration materials may follow the provisions for civil buildings. 6.0.5 The combustion performance grade of the decoration materials in various locations inside the warehouse shall not be lower than the provisions of Table 6.0.5 of this Code. ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of GB 50222-2017 be delivered?

Answer: The full copy PDF of English version of GB 50222-2017 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of GB 50222-2017_English with my colleagues?

Answer: Yes. The purchased PDF of GB 50222-2017_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- GB 50222-2017 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

Question 5: Should I purchase the latest version GB 50222-2017?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 50222-2017 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.

How to buy and download a true PDF of English version of GB 50222-2017?

A step-by-step guide to download PDF of GB 50222-2017_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "GB 50222-2017".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9